ABB Installation Products 375LR-H-5240-S 200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter…
UPC: 783786806744
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 200 Ampere current rating
- 35kV operating voltage
- Accommodates cable insulation diameters from 0.850 to 1.050 inches
- Bi-metal compression lug for reliable connections
- Supports 1/0 AWG to 2/0 AWG stranded/solid conductors (53.49 mm²)
- Includes 200ECS jacket seal for environmental protection
- Loadbreak capability for safe energized switching
Specifications
Amperage Rating | 200 A |
Application | 35 kv, 200 Amp |
Color | Black |
Conductor Range | 1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG |
Connection | Push-In |
Current Rating | 200 A |
Environmental Conditions | Fully Submersible |
Insulation | True |
Material | Bi-Metal Compression Lug, 200ECS Jacket Seal |
Material | Housing - EPDM-Rubber |
Size | Cable Insulation Diameter 0.850 inch to 1.050 inch |
Size | 0.850-1.050 inch (cable insulation diameter) |
Special Features | 35kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector |
Voltage Rating | 35 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

375LR-H5240
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
375LR-J5260
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.
375LR-K-5270
35kV 200 Amp, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
375LR-K-5250-S
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1090 inch to 1.310 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS Jacket Seal Included.
375LR-J-5220
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
375LR-L-5270
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
375LR-J-5240
35kV 200 Amp, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
375LR-H-5250
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.Frequently Asked Questions
What material is used for the elbow housing?
The elbow housing is made from 100% peroxide-cured EPDM, ensuring lasting durability.
Are these products compatible with existing systems?
Yes, the products can be universally applied to all IEEE 386 compliant interfaces without costly cable rework or installing additional elbows in existing systems.
What is the benefit of the vented ring design?
The patented vented ring design, for 25 kV and 35 kV classes, prevents partial vacuum flashover and improves safety.
How does the PBT interface shield indicate voltage?
The color-coded PBT interface shield visually indicates voltage class: red for 15 kV, blue for 25 kV, and black for 35 kV.
What is the purpose of the PBT interface shield?
The PBT interface shield provides an excellent dielectric mating surface, visual voltage indication, confirms full insertion, and prevents rubber-to-rubber sticking.
Can the bushing inserts be used in harsh conditions?
Yes, Elastimold 200 amp bushing inserts ensure exceptional performance under the harshest conditions, including being fully submerged.
What voltage classes do the bushing inserts support?
The Elastimold bushing inserts are designed for 25 kV and 35 kV system voltages, with color coding for 15 kV, 25 kV, and 35 kV classes.
What voltage classes do the loadbreak elbows support?
The Elastimold 200 amp loadbreak elbows are available for 15 kV and 25 kV series systems.
What products are described in this document?
This document describes Elastimold 200 amp loadbreak elbows and bushing inserts by ABB Installation Products.
What products are described in this document?
This document describes Elastimold 200 amp loadbreak elbows and bushing inserts by ABB Installation Products.
How to Install the ECS Jacketed Cable Sealing Kit
This guide provides step-by-step instructions for installing the ECS Jacketed Cable Sealing Kit on jacketed concentric neutral shielded cable, ensuring a proper seal and connection for 200 ECS and 600 ECS cable types.
Estimated time: 45m
Tools needed:
Utility knife, Measuring tape, Wire strippers
Supplies needed:
Cold Shrink Tube, Mastic Strip (3 pieces), Vinyl Tape, Elbow, Joint, or Terminator (as applicable)
- De-energize Apparatus
Ensure all apparatus in the work area are de-energized before beginning installation. Do not touch or move energized products. Failure to follow this instruction will result in serious or fatal injury.
- Perform Pre-Installation Checks
Inspect the kit contents for completeness and damage. Verify all components fit properly with the cable and mating products. Read the entire instructions before starting. Check cutback dimensions; the exposed semi-con between the cable jacket and device end should not exceed 2-1/2” (64mm).
- Prepare Cable Jacket
Remove the cable jacket for a distance of 2-1/2” (64mm) more than the cutback length for the cable semicon, as specified in the manufacturer’s instructions for the specific cable.
- Apply First Mastic Strip and Position Ground Wires
Wrap the first mastic strip around the cable jacket, 0” to 1/4” (0mm-6mm) from the end, stretching as needed to completely encircle the cable. Bend the ground wires back over the mastic and along the jacket, pressing them firmly into the mastic. Ensure ground wires do not touch each other when pressed into the mastic to allow a complete seal around each wire and prevent water ingress.
- Apply Second Mastic Strip and Vinyl Tape
Wrap the second mastic strip over the ground wires, above the previously applied mastic. Press the mastic to fill any voids. Overwrap the mastic and wires tightly with two half-lapped layers of vinyl tape for a width of approximately 1-1/2” (40mm).
- Prepare Cable End and Slide Cold Shrink Tube
Prepare the cable end according to the manufacturer’s instructions for the specific elbow, joint, or terminator being used. Slide the cold shrink tube onto the cable with its loose end positioned away from where the connector will be installed.
- Install Connector and Apply Third Mastic Strip
Install the elbow, joint, or terminator following its manufacturer’s instructions. For 200amp products, wrap the third mastic strip overlapping both the product end and the cable adapter. For 600amp products, wrap it immediately below the product, overlapping the cable entrance of the cable adapter. For terminators, wrap it immediately below the stress cone. Overwrap this mastic with two half-lapped layers of vinyl tape.
- Activate Cold Shrink Tube
Pull the loose end cord from the back of the cold shrink tube and unwind it in a clockwise direction until the plastic core is flush with the end of the cold shrink tube. Slide the cold shrink tube into its final position, ensuring it overlaps the elbow or joint end by at least 1 inch (25mm) for a proper seal, and continue unwinding the cord clockwise until the tube fully collapses at the product end first.
- Connect Concentric Neutral Wires
Connect the concentric neutral wires from the cable to the system ground as per the manufacturer’s instructions for the installed elbow, joint, or terminator.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.