ABB Installation Products 375LR-J5260 200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter…
UPC: 783786049707
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 200 Amp current rating for medium-voltage applications.
- 35 kV voltage rating for robust power distribution.
- Accommodates cable insulation diameters from 0.980" to 1.180".
- Bi-metal compression lug for secure and durable connections.
- Designed for 3/0 AWG stranded or 4/0 AWG solid conductors (85.01 mm²).
Specifications
Amperage Rating | 200 A |
Application | 35 kv, 200 Amp |
Color | Black |
Conductor Range | 3/0 STR/COMPR AWG , 4/0 SOL/COMPT AWG |
Connection | Push-In |
Environmental Conditions | Fully Submersible |
Insulation | True |
Material | Housing - EPDM-Rubber |
Size | Cable Insulation Diameter 0.980 inch to 1.180 inch |
Special Features | 35kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector |
Voltage Rating | 35 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 3.0900 L |
Package Weight (Metric) | 1.4020 kg |

376LR-J-5260
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.
375LR-K-5270
35kV 200 Amp, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
375LR-K-5250-S
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1090 inch to 1.310 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS Jacket Seal Included.
375LR-J-5220
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
375LR-L-5270
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
375LR-J-5240
35kV 200 Amp, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
375LR-H-5250
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
274RLR-K-5270
25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.Frequently Asked Questions
What standard do the interfaces comply with?
The interfaces are compliant with IEEE 386.
What are the voltage ratings for the loadbreak elbow?
The Elastimold 200 amp loadbreak elbow is available for 15 kV and 25 kV series systems.
What is the amperage rating of the product?
The Elastimold loadbreak elbows and bushing inserts are rated for 200 amps.
What safety features do the loadbreak elbows have?
They are fully shielded with improved insulation, have rigid probe support, a molded-in rubber-encapsulated stainless-steel pulling eye, and dual grounding eye positions.
Can the loadbreak elbow be ordered with a test point?
Yes, the loadbreak elbow is available with or without a capacitive test point.
What material is the housing made from for durability?
The housing is made from 100% peroxide-cured EPDM for lasting durability.
Can the bushing inserts operate when submerged?
Yes, the Elastimold 200 amp bushing inserts are designed for exceptional performance under harsh conditions, including being fully submerged.
How do the bushing inserts indicate voltage class?
They use a color-coded PBT interface shield: red for 15 kV, blue for 25 kV, and black for 35 kV class.
What is the purpose of the vented ring design?
The patented vented ring design (for 25 kV and 35 kV classes) prevents partial vacuum flashover during switching operations.
Are the bushing inserts compatible with existing systems?
Yes, they can be universally applied to all IEEE 386 compliant interfaces in existing systems.
How to Install Elastimold 375LR/376LR Loadbreak Elbow Connectors
This guide provides step-by-step instructions for the safe installation and initial setup of Elastimold 375LR and 376LR loadbreak elbow connectors, including cable preparation and assembly.
Estimated time: 1h
Tools needed:
Cable cutting tool, Wire strippers, Wire brush, Crimp tool, Probe wrench, Hotstick (for subsequent operation)
Supplies needed:
Elbow Connector Housing, Compression Lug, Probe, Lubricant (Do Not Substitute), UD cable, Copper wire (No. 14 AWG / 2.5mm), Appropriate grounding connector, HV insulated cap(s) or connector(s)
- Perform Pre-Installation Checks and Safety Procedures
DANGER: Ensure all apparatus is de-energized during installation or removal of parts. Inspect all components for damage, proper rating, and compatibility with mating parts. Check package contents for completeness. Thread the probe into the compression lug to ensure proper fit and check for resistance. Read all instructions thoroughly before beginning and have all required tools at hand. If the product is supplied with protective shipping covers, remove them and replace with appropriate HV insulated caps or connectors before submerging or energizing the circuit.
- Train and Cut Cable
Train the UD cable as shown in the documentation to ease future operation. Cut any excess cable squarely at the center line of the bushing, ensuring a minimum of 20 inches beyond the end of the cable pad mount transformer.
- Prepare the Cable End
Unwrap and bind the concentric neutral wires 8-1/2 inches back from the end of the cable. Carefully remove the shield and insulation from the cable end, cutting squarely and taking care not to nick the conductor. Wire brush the bare aluminum conductors and immediately install the compression lug. Rotate the lug to spread the inhibitor and position it so the contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe any excessive inhibitor from the outside of the lug and cable. Remove the insulation shield as shown in the cable cut-back template and bevel the insulation end a maximum of 1/8 inch. Thoroughly clean the insulation to remove all traces of conductive residue.
- Assemble the Elbow Connector
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant. DO NOT SUBSTITUTE other lubricants, as they may be harmful. Keep the insulation clean of dirt and grime. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off any excess grease. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, being careful not to cross-thread. The probe should turn freely for approximately four turns before becoming snug. Tighten the probe with the probe wrench until the wrench bends.
- Connect the Concentric Neutral
Using a separate copper wire (No. 14 AWG / 2.5mm) or equivalent, insert one end through the grounding eye on the elbow. Twist it tight, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Ensure adequate slack in the wires to allow for elbow operation.
- Connect Elbow to Bushing Plug (De-energized)
Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. IMPORTANT: Only lubricate if the transformer and elbow are known to be DE-ENERGIZED. Do not operate by hand; use a hotstick for connection as per operating instructions once the system is ready for energized operation. Ensure the area is clear of obstructions before making the connection.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.