Authorized ABB Distributor (Installation Products)
ABB - Installation Products 375LR-K-5270 - 35kV 200 Amp, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

ABB Installation Products 375LR-K-5270 35kV 200 Amp, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter…

UPC: 783786666775


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 35kV 200 Amp Loadbreak Elbow Connector, SKU 375LR-K-5270, is a fully shielded, dead-front medium-voltage cable connector designed for reliable power system connections in 35kV applications. This connector supports continuous current ratings of 200 amps and accommodates cable insulation diameters from 1.090 inches to 1.310 inches, ensuring compatibility with a defined range of medium-voltage cables. The connector features a bi-metal compression lug, providing a durable and conductive interface for both copper and aluminum conductors. It is specified for compressed stranded conductors from 4/0 AWG up to 250 kcmil (126.67 mm²). This model does not include a test point, simplifying installation where testing is performed via other means. The connector is engineered for loadbreak applications in power distribution networks, including underground residential distribution, commercial power, and industrial power systems. Its robust construction and precise specifications ensure secure and efficient electrical connections, critical for maintaining system integrity and operational uptime. The bi-metal lug is designed for secure crimping, offering a low-resistance connection that minimizes heat buildup and potential failure points. With a maximum phase-to-ground operating voltage of 21.1kV and phase-to-phase voltage of 36.6kV, this connector is suitable for high-voltage applications requiring reliable loadbreak capabilities. The fully shielded, submersible molded rubber housing provides environmental protection and electrical insulation, making it ideal for underground and outdoor installations.
  • Rated for 35kV applications with 200 Amp continuous current
  • Accommodates cable insulation diameters from 1.090" to 1.310"
  • Bi-metal compression lug for copper and aluminum conductors (4/0 AWG to 250 kcmil)
  • Fully shielded, dead-front molded rubber housing for environmental protection
  • Designed for loadbreak applications in underground, commercial, and industrial power systems

Specifications

Amperage Rating
200 A
Application
35 kv, 200 Amp
Color
Black
Conductor Range
4/0 STR/COMPR AWG , 250 kcmil
Connection
Push-In
Connection Type
LoadBreak Elbow Connector
Current Rating
200 A
Environmental Conditions
Fully Submersible
Insulation
True
Material
Bi-Metal Compression Lug
Material
Housing - EPDM-Rubber
Series
375LR-K
Size
Cable Insulation Diameter 1.090 inch to 1.310 inch
Special Features
35kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector
Voltage Rating
35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
3.1000 L
Package Weight (Metric)
1.4060 kg
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

375LR-L-2270

200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1090 inch to 1.310 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS Jacket Seal Included.

375LR-K-5250-S

200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1090 inch to 1.310 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS Jacket Seal Included.
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

375LR-J-5220

200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

375LR-L-5270

200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
35kV 200 Amp, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

375LR-J-5240

35kV 200 Amp, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

375LR-H-5250

200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

274RLR-K-5270

25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
35kV 200 Amp, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

375LR-J-5230

35kV 200 Amp, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

Frequently Asked Questions

How are voltage classes visually indicated?

The color-coded PBT interface shield visually indicates voltage class: red for 15 kV, blue for 25 kV, and black for 35 kV.

What is the current rating of these products?

The Elastimold loadbreak elbows and bushing inserts are rated for 200 amps.

What voltage classes do the loadbreak elbows support?

The loadbreak elbows are available for 15 kV and 25 kV systems.

What voltage classes do the bushing inserts support?

The bushing inserts are available for 15 kV, 25 kV, and 35 kV system voltages.

How does the vented ring design improve safety?

The patented vented ring design, for 25 kV and 35 kV classes, prevents partial vacuum flashover during switching operations.

Are these products compatible with existing systems?

Yes, they can be universally applied to all IEEE 386 compliant interfaces without costly cable rework or installing additional elbows.

Can the bushing inserts be used in submerged conditions?

Yes, Elastimold 200 amp bushing inserts are designed for exceptional performance under harsh conditions, including being fully submerged.

What material is used for the elbow housing?

The elbow housing is made from 100% peroxide-cured EPDM for lasting durability.

Do the elbows offer an integral jacket seal?

Yes, an integral jacket seal is available for complete sealing.

Are capacitive test points available?

Yes, the loadbreak elbows are available with or without a capacitive test point.

How to Install 375LR/376LR Loadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe installation and assembly of 375LR and 376LR Loadbreak Elbow Connectors, including cable preparation, elbow assembly, neutral connection, and initial connection to a bushing.

Estimated time: 1h 30m

Tools needed:

Probe Wrench, Wire brush, Crimp tool, Hotstick, Suitable sensing device (for capacitive test points)

Supplies needed:

Elbow Connector Housing, Compression Lug, Probe, Lubricant (Do Not Substitute), UD cable, Copper wire (No. 14 AWG / 2.5mm or equivalent), Appropriate connector (for neutral wires), HV insulated cap(s) or connector(s), Silicone grease

  1. Prepare for Installation and Safety Checks

    De-energize all apparatus. Inspect all parts for damage, proper rating, and compatibility with mating parts. Ensure all required tools and supplies are at hand and maintain cleanliness throughout the procedure. If the product is supplied with protective shipping covers, remove them and replace with appropriate HV insulated caps or connectors before submerging or energizing the circuit.

  2. Train and Prepare Cable

    Train the UD cable as shown in the diagram to ease operation, ensuring a minimum of 20 inches of cable extends beyond the end of the cable pad mount transformer. Cut excess cable squarely at the center line of the bushing. Unwrap and bind the concentric neutral wires 8-1/2 inches back from the end of the cable. Remove the shield and insulation from the cable end, cutting squarely and taking care not to nick the conductor.

  3. Install Compression Lug

    Wire brush the bare aluminum conductors thoroughly. Immediately install the compression lug, rotating it to spread the inhibitor. Position the compression lug so its contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart packaged with the compression lug, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe any excessive inhibitor from the outside of the lug and cable.

  4. Prepare Insulation Shield

    Remove the insulation shield as indicated by the cable cut-back template. Bevel the insulation end a maximum of 1/8 inch. Thoroughly clean the insulation to remove all traces of conductive residue, ensuring the surface is straight, smooth, and squared without any cuts or nicks.

  5. Assemble Elbow Housing

    Lubricate the cable insulation and the inside of the elbow housing with the lubricant supplied; do not substitute other lubricants. Slide the elbow connector onto the cable with a back-and-forth twisting motion. Wipe off all excess grease from the exterior.

  6. Thread and Tighten Probe

    Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, taking care not to cross-thread. The probe must turn freely for approximately four turns before becoming snug. Tighten the probe with the supplied probe wrench until the wrench bends, indicating proper torque.

  7. Connect Concentric Neutral

    Using a separate copper wire (No. 14 AWG / 2.5mm or equivalent), insert one end through the grounding eye on the elbow. Twist it tight, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Provide adequate slack in the wires for elbow operation.

  8. Connect Elbow to Bushing (Loadmake Operation)

    Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant only if the transformer and elbow are known to be de-energized. Securely fasten a hotstick to the loadbreak connector pulling eye. After establishing firm footing and positive control, withdraw the elbow from the apparatus parking stand with a fast, straight, firm motion. Insert the probe tip approximately 2 inches into the bushing, then immediately push the elbow home with a fast, firm, straight motion, applying sufficient force to engage the internal lock on the elbow connector and bushing interface.

  9. Perform Voltage Test (for 376LR only)

    If installing a 376LR with a test point, remove the test point cap with a hotstick by peeling it off at an angle rather than pulling directly in line. WARNING: The voltage test point is a capacitance device; do not use conventional voltage measuring equipment. Test with a suitable sensing device made for use with separable connectors manufactured with capacitive test points to determine if the cable is energized, following the manufacturer’s directions for the meter. Treat the elbow as energized until the "no voltage" indication is confirmed by other means. After testing, clean and lubricate the inside surface of the cap with silicone grease and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.