ABB - Installation Products 274ELR-6689-5210 - 25kV, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact. Cable Insulation Diameter 0.665 inch to 0.895 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67. No Sealing Kit

ABB Installation Products 274ELR-6689-5210 25kV, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length…

UPC: 075114307550


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 274ELR-6689-5210 is a 25kV Loadbreak Repair Elbow Connector designed for medium-voltage cable systems requiring reliable, field-repairable connections. This elbow connector integrates a test point for safe voltage verification without service interruption, making it ideal for maintenance and emergency repairs in underground or overhead distribution networks. Key specifications include an extended contact and housing design that adds 3-1/4 inches to the overall length, providing additional clearance for hot-stick operations. The connector accommodates cable insulation diameters from 0.665 inch to 0.895 inch and supports compressed stranded conductors up to AWG #3 or solid #2 (26.67 mm²). The included 02509X Bi-Metal Contact ensures compatibility with both copper and aluminum conductors, while the Bi-Metal Compression Lug provides a secure, low-resistance termination. This repair elbow is rated for 25kV class systems and is compatible with industry-standard loadbreak interfaces. The absence of a sealing kit allows for flexible installation configurations but requires proper environmental protection per application requirements. Use this connector in utility substations, switchgear, and cable terminations where quick, reliable repairs are critical to system uptime. The 274ELR-6689-5210 is part of ABB’s Elastimold® family of loadbreak connectors, designed to meet ANSI/IEEE Standard 386 for 25kV class systems. It supports continuous and loadbreak operations at 200A, with a momentary fault close rating of 10kA symmetrical for 10 cycles. The connector’s peroxide-cured insulation and jacket ensure long-term reliability in harsh environments, including submersible applications. Compatible with ABB’s 25kV elbow connectors and accessories such as the 370TR test rod and 370GLR grounding elbow, this repair elbow provides a versatile solution for energized operations. Its adjustable design facilitates optimal positioning, reducing installation time and improving operational safety.
  • 25kV class, 200A continuous and loadbreak rated
  • Integrated test point for safe voltage verification without service interruption
  • Extended contact and housing design adds 3-1/4 inches for hot-stick clearance
  • Accommodates cable insulation diameters from 0.665" to 0.895"
  • Bi-Metal Contact and Compression Lug for copper and aluminum conductors

Specifications

Amperage Rating
200 A
Application
Designed for connecting to and operating 25kV Class, 125kV BIL apparatus
Color
Black
Conductor Range
#3 STR/COMPR AWG , #2 SOL/COMPT AWG
Connection
Compression
Connection Type
Compression Lug
Environmental Conditions
Fully Submersible
Insulation
True
Length
11.71 in
Length
297.434 mm
Material
Bi-Metal
Material
Bi-Metal, Poly
Material
Housing - EPDM-Rubber
Series
274ELR
Size
Cable Insulation Diameter 0.665 inch to 0.895 inch
Size
0.665-0.895 inches (cable insulation)
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured insulation, insert and jacket. Provision for hot stick operation, Provision for ground wire connection. Wide cable range with minimum number of sizes. Extended Length Housing and Compression Lug - plus 3-1/4 inch (82.6mm). Non-Corrosive Capacitive Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Repair Elbow Connector with Test Point
Voltage Rating
25 kV
Voltage Rating
25kV
Width
8.4 in
Width
213.36 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67.

274RLR-G-5210

25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67.
25kV, 200 Amp, Extended Elbow, No Sealing Kit, 200 Amp, 25kV, Loadbreak Repair Elbow Connector, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact. Cable Insulation Diameter 0.880 inch to 1.100 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

273ELR-88110-5250

25kV, 200 Amp, Extended Elbow, No Sealing Kit, 200 Amp, 25kV, Loadbreak Repair Elbow Connector, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact. Cable Insulation Diameter 0.880 inch to 1.100 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
200 Amp, 25kV, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact. No Sealing Kit, Cable Insulation Diameter 0.740 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

274ELR-7495-5240

200 Amp, 25kV, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact. No Sealing Kit, Cable Insulation Diameter 0.740 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
25kV, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact. Cable Insulation Diameter 0.665 inch to 0.895 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62. No Sealing Kit.

274ELR-6689-5220

25kV, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact. Cable Insulation Diameter 0.665 inch to 0.895 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62. No Sealing Kit.
25kV, 200 Amp, Extended Elbow, No Sealing Kit, 200 Amp, 25kV, Loadbreak Repair Elbow Connector, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact. Cable Insulation Diameter 0.880 inch to 1.100 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

273ELR-88110-5270

25kV, 200 Amp, Extended Elbow, No Sealing Kit, 200 Amp, 25kV, Loadbreak Repair Elbow Connector, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact. Cable Insulation Diameter 0.880 inch to 1.100 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
25kV, 200 Amps, Loadbreak Elbow, no Sealing Kit, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Conductor, Conductor Size #1 Stranded/Compressed, 1/0 Solid/Compact. With Test Point. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installion Instruction Sheet and Crimp Chart.

262LR-E5230

25kV, 200 Amps, Loadbreak Elbow, no Sealing Kit, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Conductor, Conductor Size #1 Stranded/Compressed, 1/0 Solid/Compact. With Test Point. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installion Instruction Sheet and Crimp Chart.
25kV, 200 Amps, Loadbreak Elbow, no Sealing Kit, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Conductor, Conductor Size 1/0 Stranded/Compressed, 2/0 Solid/Compact. With Test Point. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installion Instruction Sheet and Crimp Chart.

262LR-E5240

25kV, 200 Amps, Loadbreak Elbow, no Sealing Kit, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Conductor, Conductor Size 1/0 Stranded/Compressed, 2/0 Solid/Compact. With Test Point. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installion Instruction Sheet and Crimp Chart.
25kV, 200 Amps, Loadbreak Elbow, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Conductor, Conductor Size #1 Stranded/Compressed, 1/0 Solid/Compact. With Test Point. 200ECS-G2 Jacket Seal and Grounding Kit Included. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installion Instruction Sheet and Crimp Chart.

262LR-E5230-SG2

25kV, 200 Amps, Loadbreak Elbow, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Conductor, Conductor Size #1 Stranded/Compressed, 1/0 Solid/Compact. With Test Point. 200ECS-G2 Jacket Seal and Grounding Kit Included. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installion Instruction Sheet and Crimp Chart.

Frequently Asked Questions

Where are Elastimold elbows manufactured?

Elastimold 200 A repair and replacement elbows are designed, molded, tested, and assembled in Albuquerque, New Mexico, USA.

What is the purpose of these elbow connectors?

These elbow connectors facilitate transitioning from live-front to dead-front equipment without splicing or pulling new cable, saving time and expense.

What is the extended length of the repair elbow?

The repair elbow features an extended housing and compression lug length that is 3 1/4 inches longer than the standard elbow.

What is the extended length of the replacement elbow?

The replacement elbow extends its housing and compression lug length to 8 7/8 inches over the standard elbow.

Do these elbow connectors include a test point?

Both repair and replacement elbows are available with an optional built-in capacitive test point to allow testing of the circuit for the presence of voltage.

What certifications do these elbows have?

These elbows are IEEE 386 compliant, ANSI certified, and Rural Utilities Service (RUS) accepted.

What is the voltage class for the 274ELR product?

The 274ELR repair elbow connector with test point is designed for a 25 kV voltage class.

Is a jacket seal available for these elbows?

Yes, these elbows are also available with a 200ECS jacket seal included. This is highly recommended and indicated by adding an "-S" suffix to the catalog number.

What is the catalog number for the test point cap?

The catalog number for the test point cap is 156-7.

What cable insulation diameter does 274ELR-6689 accommodate?

The 274ELR-6689 elbow accommodates a cable insulation diameter ranging from 0.665 to 0.895 inches.

How to Install Elastimold 273ELR/274ELR Loadbreak Elbow Connectors

This guide provides comprehensive instructions for the safe installation and initial setup of Elastimold 273ELR and 274ELR Loadbreak Elbow Connectors, designed for terminating UD cable with concentric neutral and extruded insulation shielding.

Estimated time: 1h 30m

Tools needed:

Probe Wrench / Pin Wrench, Hotstick (full insulated live-line tool), Appropriate crimp tool, Wire brush, Suitable sensing device (for capacitive test points)

Supplies needed:

Elbow Connector Housing (273ELR or 274ELR), Compression Lug, Probe, Lubricant (Do Not Substitute), No. 14 AWG / 2.5mm copper wire (or equivalent), Appropriate ground connector, HV insulated cap(s) or connector(s) (if replacing shipping covers)

  1. Perform Initial Safety Checks and Gather Materials

    DANGER: All apparatus must be de-energized during installation or removal of parts, except for test point caps and indicators. Inspect all components for damage, proper rating, and compatibility with mating parts. Gather all required tools and supplies, and read these instructions completely before starting. Ensure cleanliness throughout the procedure. If the product is supplied with protective shipping covers, remove them and replace with appropriate HV insulated caps or connectors before submerging or energizing the circuit.

  2. Train and Cut Cable

    Train the UD cable as shown in the documentation to ease future operation, ensuring a minimum of 20 inches of cable extends beyond the end of the cable pad mount transformer. For new installations, cut the excess cable squarely at the center line of the bushing.

  3. Prepare Cable End

    Unwrap and bind the concentric neutral wires 'X' inches back from the end of the cable (refer to the compression lug X dimension chart, e.g., 13 inches for 02200XXX/02500XXX/02509XXX). Carefully remove the shield and insulation from the cable end, cutting squarely and taking extreme care not to nick the conductor. The cut should be straight, smooth, and squared.

  4. Install Compression Lug

    Wire brush the bare aluminum conductors immediately after preparation. Install the compression lug, rotating it to spread the inhibitor evenly. Position the compression lug so that its contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart provided with the compression lug, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe any excessive inhibitor from the outside of the lug and cable.

  5. Prepare Insulation Shield and Clean Insulation

    Remove the insulation shield as indicated in the documentation (typically 10 inches from the end of the lug). Bevel the insulation end a maximum of 1/8 inch. Thoroughly clean the insulation to remove all traces of conductive residue, ensuring a straight, smooth, and squared finish without cuts or nicks.

  6. Assemble Elbow Housing

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant. DO NOT SUBSTITUTE, as other lubricants may be harmful to the product. Slide the elbow connector onto the cable using a back and forth twisting motion. Wipe off all excess grease from the exterior.

  7. Install Probe

    Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, taking care not to cross-thread. The probe must turn freely for approximately four turns before becoming snug. Tighten the probe with a wrench until the wrench bends, indicating proper torque.

  8. Connect Concentric Neutral

    Insert one end of a separate copper wire (No. 14 AWG / 2.5mm or equivalent) through the grounding eye on the elbow. Twist it tightly, ensuring not to damage the eye. Twist all concentric neutral wires and the newly attached grounding wire together. Connect this twisted bundle to ground using an appropriate connector, providing adequate slack in the wires to allow for elbow operation.

  9. Connect Elbow to Bushing Plug (De-energized)

    CAUTION: Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant ONLY IF THE TRANSFORMER AND ELBOW ARE KNOWN TO BE DE-ENERGIZED. Securely fasten a hotstick to the loadbreak connector pulling eye. After establishing firm footing and positive control, place the elbow connector receptacle area over the bushing plug, inserting the elbow male contact into the bushing until the first slight resistance is felt. Immediately push the elbow home with a fast, firm, straight motion to engage the internal lock on the elbow and bushing interface. Apply sufficient force to ensure the internal lock engages. DO NOT OPERATE BY HAND.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.