ABB - Installation Products 262LR-D5270 - 25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 4/0 Stranded Wire Size, Bi-Metal Compression Lug.
More images

ABB Installation Products 262LR-D5270 25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable…

UPC: 075114192620


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Minimum Qty: 12

Multiplier: 12

*Contact for lower quantities*

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 262LR-D5270 Loadbreak Elbow Connector is a 25kV, 200A rated accessory engineered for underground distribution systems. This elbow connector features a bi-metal compression lug for reliable, long-term connections on 4/0 AWG stranded copper conductors with cable insulation diameters between 0.890 and 1.220 inches. The integrated test point enables safe voltage detection without disconnecting the elbow, reducing downtime during maintenance or fault isolation. The loadbreak design allows hot-swapping under load, minimizing service interruptions in critical applications. The bi-metal compression lug ensures compatibility with both copper and aluminum conductors, providing flexibility in system design. This connector is ideal for pad-mounted transformers, switchgear, and underground residential or commercial feeders. The catalog number follows the ABB 262LR-W5X format, where 'W' represents the insulation diameter code (0.890-1.220 inches) and 'X' denotes the conductor size code (4/0 AWG). The bi-metal compression lug code for 4/0 stranded wire is 260, ensuring optimal electrical and mechanical performance.
  • 25kV, 200A rated loadbreak elbow connector for underground distribution systems
  • Bi-metal compression lug compatible with 4/0 AWG stranded copper and aluminum conductors
  • Integrated test point enables safe voltage detection without disconnection
  • Loadbreak design allows hot-swapping under load to minimize service interruptions
  • Integrated test point for safe voltage detection

Specifications

Amperage Rating
200 A
Application
200 kV, 200 Amp
Color
Black
Conductor Range
4/0 STR/COMPR AWG , 250 kcmil
Connection Type
Compression Lug
Current Rating
200A
Environmental Conditions
All Weather Conditions
Insulation
True
Material
Housing - EPDM-Rubber
Material
Bi-Metal Compression Lug
Series
262LR
Size
9.03 inch (299.4 mm) X 8.20 inch (208.3 mm) not including probe, 2.86 inch (72.6 mm) Diameter
Size
0.890-1.220 inch Cable Insulation Diameter, 4/0 Stranded Wire Size
Special Features
28kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard. Non-corrosive capacitive test point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector with Test Point
Voltage Rating
28 kV
Voltage Rating
25kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
2.3200 L
Package Weight (Metric)
1.0520 kg
15/25kV, 600 Amp, Deadbreak, Compact H Spiking Aid Joint with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.

K656CHSL-H0270

15/25kV, 600 Amp, Deadbreak, Compact H Spiking Aid Joint with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.
200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS-G3 Jacket Seal and Grounding Kit Included.

262LR-D5240-SG3

200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS-G3 Jacket Seal and Grounding Kit Included.
28kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #2 Stranded Wire Size, Bi-Metal Compression Lug.

262LRJS-C5220

28kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #2 Stranded Wire Size, Bi-Metal Compression Lug.
25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 2/0 Stranded Wire Size, Bi-Metal Compression Lug.

262LR-D5250

25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 2/0 Stranded Wire Size, Bi-Metal Compression Lug.
25kV 200A Loadbreak Jacket Seal Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, 2/0 Stranded Wire Size, Bi-Metal Compression Lug.

262LRJS-C5250

25kV 200A Loadbreak Jacket Seal Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, 2/0 Stranded Wire Size, Bi-Metal Compression Lug.
25kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #1 Stranded Wire Size, Bi-Metal Compression Lug.

262LRJS-C5230

25kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #1 Stranded Wire Size, Bi-Metal Compression Lug.
200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS Jacket Seal Included.

262LR-D5250-S

200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS Jacket Seal Included.
25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 3/0 Stranded Wire Size, Bi-Metal Compression Lug.

262LR-D5260

25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 3/0 Stranded Wire Size, Bi-Metal Compression Lug.

Frequently Asked Questions

What standards and certifications does this product meet?

The product is IEEE 386 compliant and has ANSI certification, in addition to RUS acceptance.

Is the Elastimold loadbreak elbow RUS accepted?

Yes, the enhanced Elastimold 200 amp loadbreak elbow has Rural Utilities Service (RUS) acceptance from the U.S. Department of Agriculture (USDA).

What are the voltage ratings for this loadbreak elbow?

The loadbreak elbow is available for 15 kV and 25 kV applications.

What is the Elastimold 200 amp loadbreak elbow?

It is an enhanced 200 amp loadbreak elbow, available in 15 kV and 25 kV series, designed for switching operations.

What standards and certifications does this product meet?

The product is IEEE 386 compliant and has ANSI certification, in addition to RUS acceptance.

Is the Elastimold loadbreak elbow RUS accepted?

Yes, the enhanced Elastimold 200 amp loadbreak elbow has Rural Utilities Service (RUS) acceptance from the U.S. Department of Agriculture (USDA).

What are the voltage ratings for this loadbreak elbow?

The loadbreak elbow is available for 15 kV and 25 kV applications.

What is the Elastimold 200 amp loadbreak elbow?

It is an enhanced 200 amp loadbreak elbow, available in 15 kV and 25 kV series, designed for switching operations.

Is the Elastimold loadbreak elbow RUS accepted?

Yes, the enhanced Elastimold 200 amp loadbreak elbow has Rural Utilities Service (RUS) acceptance from the U.S. Department of Agriculture (USDA).

What are the voltage ratings for this loadbreak elbow?

The loadbreak elbow is available for 15 kV and 25 kV applications.

How to Install 262LR Loadbreak Elbow Connectors

This guide provides step-by-step instructions for preparing the cable, assembling, and installing the 262LR Loadbreak Elbow Connector onto a de-energized 25kV class bushing.

Estimated time: 1h

Tools needed:

Probe Wrench, Wire brush, Crimp tool, Wire strippers, Utility knife or cable knife, Hotstick

Supplies needed:

Elbow Connector Housing (262LR), Compression Lug, Probe, Lubricant (supplied with kit, do not substitute), Copper wire (No. 14 AWG / 2.5mm or equivalent), Appropriate connector (for neutral wires), Vinyl tape (if using jacketed cable with drain wires), Conductive copper tape (if using 200ECS-G2 kit), Cold shrink tube (if using 200ECS, 200ECS-G1, or 200ECS-G2 sealing kits)

  1. Safety First: De-energize and Inspect Components

    DANGER: Confirm that all apparatus in the work area are de-energized before beginning installation. Do not touch or move energized products. Inspect all components (elbow housing, compression lug, probe) for damage, correct rating, and compatibility with the cable and mating bushing. Check the package contents for completeness. Thread the probe into the compression lug by hand to check for resistance; replace damaged components if resistance is encountered.

  2. Prepare the Cable According to Type

    DANGER: Ensure the cable is de-energized before proceeding. Train the cable to ensure sufficient slack for future operation. Based on your specific cable type (Non-Jacketed Concentric Neutral, Jacketed Concentric Neutral, Jacketed Cable with Drain Wires, or Jacketed Copper Tape Shield Cable), follow the detailed instructions in the product manual for cutting, jacket removal, neutral/drain wire management, and shield preparation. If using a cold shrink sealing kit (e.g., 200ECS, 200ECS-G1, 200ECS-G2), slide the cold shrink tube onto the cable loose end first at this stage.

  3. Prepare Cable End and Install Compression Lug

    Using a cable cut-back template for guidance, remove 2-1/8” (55mm) of the shield and insulation from the cable end, cutting squarely without nicking the conductor. Wire brush the bare aluminum conductors thoroughly. Immediately install the compression lug, rotating it to spread the inhibitor. Position the compression lug so its contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart provided with the lug, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe any excess inhibitor from the outside of the lug and cable. Remove the insulation shield 6-7/8” (175mm) back from the lug, ensuring a straight, smooth, and squared cut. Bevel the insulation end a maximum of 1/8” (5mm). Thoroughly clean the insulation to remove all traces of dirt or excess inhibitor.

  4. Assemble the Elbow Connector

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant. DO NOT SUBSTITUTE other lubricants, as they may be harmful to the product. Keep the insulation clean of dirt and grime. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off all excess lubricant. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends, indicating proper torque.

  5. Ground the Elbow

    Insert one end of a separate copper wire (No. 14 AWG / 2.5mm or equivalent) through the grounding eye on the elbow. Twist it tightly, taking care not to damage the eye. If the elbow was preordered with a ground wire, proceed to the next step. For concentric neutral cables, twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack in the wires for elbow operation. If using a cold shrink grounding kit, refer to the instructions provided with that kit to complete the grounding installation.

  6. Connect the Elbow to the Bushing

    DANGER: Re-confirm that the transformer and the mating bushing are de-energized before making the connection. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a hotstick to the loadbreak connector pulling eye. Insert the probe tip approximately 2” (50mm) into the bushing. Immediately push the elbow home with a fast, firm, straight motion, using sufficient force to engage the internal lock on the elbow connector and bushing interface. DO NOT OPERATE BY HAND.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.