ABB - Installation Products 261LR-E5270 - 25/28kV, 200 Amps, Loadbreak Elbow, no Sealing Kit, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Compression Lug, Conductor Size 4/0 Stranded/Compressed, 250 Solid/Compact. No Test Point. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installion Instruction Sheet and Crimp Chart.

ABB Installation Products 261LR-E5270 25/28kV, 200 Amps, Loadbreak Elbow, no Sealing Kit, Cable Insulation Diameter…

UPC: 075114312158


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 261LR-E5270 is a 25/28kV, 200 Amp Class loadbreak elbow connector designed for medium-voltage distribution systems. This fully shielded, fully submersible molded rubber housing connector meets ANSI/IEEE Standard 386 and is rated for 28kV phase-to-phase and 16.2kV phase-to-ground operating voltage. It supports cable insulation diameters from 1.090 to 1.310 inches (27.69-33.27 mm), accommodating 4/0 stranded/compressed or 250 solid/compact conductors. The bi-metal compression lug ensures compatibility with both copper and aluminum conductors, eliminating the need for separate lugs and simplifying installation. The kit includes the elbow connector housing, bi-metal compression lug, probe, probe wrench, lubricant, installation instruction sheet, and crimp chart. This connector features provisions for hot stick operation and ground wire connection, enabling safe loadmaking and loadbreak operations in energized systems. With a 100% peroxide-cured EPDM construction, it delivers long-term reliability and environmental resistance. Typical applications include underground distribution systems, pad-mounted transformers, and switchgear where visible disconnects and loadbreak functionality are required. The absence of a sealing kit makes it suitable for environments where adjacent components provide environmental protection.
  • Rated 25/28kV, 200 Amp Class loadbreak connector per ANSI/IEEE Standard 386
  • Supports cable insulation diameters 1.090-1.310" (27.69-33.27 mm)
  • Bi-metal compression lug for copper or aluminum conductors (4/0 stranded/compressed or 250 solid/compact)
  • Fully shielded, fully submersible molded rubber housing with 100% peroxide-cured EPDM construction
  • Includes probe, probe wrench, lubricant, installation instructions, and crimp chart

Specifications

Amperage Rating
200 A
Application
25/28 kV, 200 Amp
Color
Black
Conductor Range
4/0 STR/COMPR AWG , 250 kcmil
Environmental Conditions
All Weather Conditions
Insulation
True
Material
Housing - EPDM-Rubber
Number Of Conductors
250 Solid/Compact
Size
9.03 inch (299.4 mm) X 7.89 inch (200.4 mm) not including probe, 2.86 inch (72.6 mm) Diameter
Special Features
25/28kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector
Voltage Rating
25 to 28 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
2.2400 L
Package Weight (Metric)
1.0160 kg
25kv, 600 Amp Series, Deadbreak Combo-T. Connector Elbow with Intergral 200 Amp Loadbreak Tap Plug with Test Point. Cable Insulation Diameter 0.980 to 1.180 inches (24.9-30.0mm). Aluminum Conductor Material, Conductor Code 270 - 4/0 Stranded/Compressed or 250 Solid/Compact. No Sealing Kit.

K656CETP-J0270

25kv, 600 Amp Series, Deadbreak Combo-T. Connector Elbow with Intergral 200 Amp Loadbreak Tap Plug with Test Point. Cable Insulation Diameter 0.980 to 1.180 inches (24.9-30.0mm). Aluminum Conductor Material, Conductor Code 270 - 4/0 Stranded/Compressed or 250 Solid/Compact. No Sealing Kit.
25/28kV, 200 Amps, Loadbreak Elbow, Built in Jacket Seal, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Compression Lug, Conductor Size 1/0 Stranded/Compressed, 2/0 Solid/Compact. No Test Point. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installion Instruction Sheet and Crimp Chart.

261LRJS-E5240

25/28kV, 200 Amps, Loadbreak Elbow, Built in Jacket Seal, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Compression Lug, Conductor Size 1/0 Stranded/Compressed, 2/0 Solid/Compact. No Test Point. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installion Instruction Sheet and Crimp Chart.
25/28kV, 200 Amps, Loadbreak Elbow, Built in Jacket Seal, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Compression Lug, Conductor Size 4/0 Stranded/Compressed, 250 Solid/Compact. No Test Point. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installion Instruction Sheet and Crimp Chart.

261LRJS-E5270

25/28kV, 200 Amps, Loadbreak Elbow, Built in Jacket Seal, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Compression Lug, Conductor Size 4/0 Stranded/Compressed, 250 Solid/Compact. No Test Point. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installion Instruction Sheet and Crimp Chart.
15/25 kV, 600 Amp, Deadbreak, Elbow Kit, with Insulated Plug, Cap, Stud, Copper Lug, and Cable Adapter. Cable Insulation Diameter 1.515-1.780. Conductor Size kcmil Compressed/Stranded 1000.

K655LR-N2410

15/25 kV, 600 Amp, Deadbreak, Elbow Kit, with Insulated Plug, Cap, Stud, Copper Lug, and Cable Adapter. Cable Insulation Diameter 1.515-1.780. Conductor Size kcmil Compressed/Stranded 1000.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size Compressed/Stranded 250 or Compact/Solid 300.

K656LR-G0280

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size Compressed/Stranded 250 or Compact/Solid 300.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Bi-Metal Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size Compressed/Stranded 700/750 or Compact/Solid 900. Cold-Shrinkable Jacket Seal Included.

K656LR-M5380-S

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Bi-Metal Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size Compressed/Stranded 700/750 or Compact/Solid 900. Cold-Shrinkable Jacket Seal Included.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size Compressed/Stranded 2/0 or Compact/Solid 3/0 or mm2 Compact 70.

K656LR-H0250

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 0.850 inch to 1.050 inch. Conductor Size Compressed/Stranded 2/0 or Compact/Solid 3/0 or mm2 Compact 70.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size Compressed/Stranded 700/750 or Compact/Solid 900.

K656LR-N0380

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size Compressed/Stranded 700/750 or Compact/Solid 900.

Frequently Asked Questions

What material is the pulling eye made from?

The elbow features a robust stainless-steel pulling eye, which promotes durable hotstick control.

What does RUS acceptance mean for this product?

RUS acceptance from the USDA authorizes its use in rural infrastructure construction and improvements.

What certifications does the Elastimold elbow have?

The product is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance from the U.S. Department of Agriculture (USDA).

Is the elbow compatible with Elastimold bushings?

Yes, it offers a no-stick interface and lifetime ease of operation when used with Elastimold bushings.

What safety features does the elbow include?

It features improved insulation for 15 kV elbows, rigid probe support, a no-stick interface with Elastimold bushings, a robust stainless-steel pulling eye, and dual grounding eye positions.

What are the voltage ratings for this elbow?

The Elastimold 200 amp loadbreak elbow is available in 15 kV and 25 kV series.

What is the Elastimold 200 amp loadbreak elbow?

It is an enhanced 200 amp loadbreak elbow, available in 15 kV and 25 kV series, designed for easier switching operations.

What material is the pulling eye made from?

The elbow features a robust stainless-steel pulling eye, which promotes durable hotstick control.

What does RUS acceptance mean for this product?

RUS acceptance from the USDA authorizes its use in rural infrastructure construction and improvements.

What certifications does the Elastimold elbow have?

The product is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance from the U.S. Department of Agriculture (USDA).

How to Install 261LR and 262LR Loadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe installation and initial setup of 261LR and 262LR Loadbreak Elbow Connectors on various types of underground distribution cables. Ensure all safety precautions are followed.

Estimated time: 1h 30m

Tools needed:

Cable cutting tool, Wire strippers, Wire brush, Crimp tool (specific to compression lug), Probe wrench, Hotstick (fully insulated live-line tool)

Supplies needed:

Elbow Connector Housing, Compression Lug, Probe, Lubricant (supplied, do not substitute), Copper wire (No. 14 AWG / 2.5mm) or equivalent, Appropriate connector for neutral wires, Vinyl tape (if applicable for cable type), Cold shrink tube (if using sealing kit), Conductive copper tape (if using 200ECS-G2 kit), Insulated cap (to be removed from bushing)

  1. Perform Initial Safety Checks and Component Inspection

    DANGER: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products. This product must be installed only by competent personnel trained in high voltage electrical equipment safety. Inspect all parts for damage, rating, and compatibility with mating parts. Check package contents to ensure they are complete and undamaged. Verify proper fit with cable and/or mating products. Thread the probe into the compression lug to check for resistance; replace damaged components if resistance is encountered. Read all instructions before starting and have all required tools ready, maintaining cleanliness throughout the procedure.

  2. Prepare the Cable for Connector Installation

    Train the cable to ensure adequate slack for ease of operation. Prepare neutral or drain wires according to your cable type (e.g., pull extra length, bind, or remove outer jacket). Cut the excess cable squarely at the centerline of the bushing. Remove the outer jacket and copper tape shield (if applicable) to the specified dimensions for your cable type. Remove the insulation shield and insulation 2-1/8 inches (55mm) from the cable end, cutting squarely without nicking the conductor. Wire brush bare aluminum conductors immediately and install the compression lug, rotating to spread inhibitor. Align the lug's threaded hole with the bushing bore and crimp according to the lug's chart, rotating 180 degrees for each successive crimp. Carefully wipe off excess inhibitor. Remove the insulation shield 6-7/8 inches (175mm) from the lug and bevel the insulation end 1/8 inch (5mm) maximum. Thoroughly clean the insulation to remove all traces of dirt or excess inhibitor.

  3. Assemble the Elbow Connector onto the Cable

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant. DO NOT SUBSTITUTE other lubricants, as they may be harmful. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off all excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends, indicating proper torque.

  4. Ground the Elbow Connector

    Insert one end of a separate copper wire (No. 14 AWG / 2.5mm) or equivalent through the grounding eye on the elbow. Twist the wire tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Ensure adequate slack in the wires for elbow operation. If using a cold shrink grounding kit, refer to its specific instructions for completion.

  5. Connect the Elbow to the Bushing Plug

    CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED before proceeding. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Remove the insulated cap from the bushing by attaching a hotstick tool to the insulated cap pulling eye and following its instructions. Securely fasten the hotstick to the loadbreak connector pulling eye. Insert the probe tip approximately 2 inches (50mm) into the bushing. Immediately push the elbow home with a fast, firm, straight motion, using sufficient force to engage the internal lock on the elbow connector and bushing interface. DO NOT OPERATE BY HAND.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.