ABB Installation Products 262LR-D5240 25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable…
UPC: 075114192255
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 25kV voltage rating, 200 Amp current capacity
- Built-in test point for safe voltage verification without de-energization
- Supports cable insulation diameters from 0.890" to 1.220"
- Accommodates 1/0 stranded or 2/0 solid conductors with bi-metal compression lug
- Part of ABB’s 262LR series for medium-voltage loadbreak applications
Specifications
Amperage Rating | 200 A |
Application | 200 kV, 200 Amp |
Color | Black |
Conductor Range | 1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG |
Connection | Compression |
Environmental Conditions | All Weather Conditions |
Insulation | True |
Material | Housing - EPDM-Rubber |
Size | 9.03 inch (299.4 mm) X 8.20 inch (208.3 mm) not including probe, 2.86 inch (72.6 mm) Diameter |
Special Features | 28kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard. Non-corrosive capacitive test point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector with Test Point |
Voltage Rating | 28 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 2.3200 L |
Package Weight (Metric) | 1.0520 kg |

262LR-C2240
28kV, 200 Amps, Loadbreak Elbow Connector with Test Point, No Sealing Kit, .805 inch - 1.060 Inch Cable Insulation Diameter, 1/0 Stranded, 2/0 Solid Wire Size, Copper Compression Lug. Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Tube of Lubricant, Crimp Chart and Installation Instructions.
262LR-D5260-S
200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01. 200ECS Jacket Seal Included.
262LR-D5270
25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 4/0 Stranded Wire Size, Bi-Metal Compression Lug.
262LR-D5240-SG3
200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS-G3 Jacket Seal and Grounding Kit Included.
262LRJS-C5220
28kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #2 Stranded Wire Size, Bi-Metal Compression Lug.
262LR-D5250
25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 2/0 Stranded Wire Size, Bi-Metal Compression Lug.
262LRJS-C5250
25kV 200A Loadbreak Jacket Seal Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, 2/0 Stranded Wire Size, Bi-Metal Compression Lug.
262LRJS-C5230
25kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #1 Stranded Wire Size, Bi-Metal Compression Lug.Frequently Asked Questions
What is the maximum voltage rating for this elbow connector?
The ABB 262LR-D5240 loadbreak elbow connector has a maximum voltage rating of 25kV.
What is the current carrying capacity of this connector?
This loadbreak elbow connector is rated for 200 Amps.
What cable insulation diameters can this connector accommodate?
The connector is designed for cable insulation diameters ranging from 0.890 inches to 1.220 inches.
What wire sizes are compatible with this elbow connector?
It supports 1/0 stranded wire or 2/0 solid wire.
What type of lug is used for conductor connection?
The connector features a bi-metal compression lug for secure termination.
Does this connector have a test point?
Yes, the ABB 262LR-D5240 includes a test point for voltage verification.
How to Install 261LR and 262LR Loadbreak Elbow Connectors
This guide provides step-by-step instructions for the safe installation and initial connection of 261LR (without test point) and 262LR (with test point) Loadbreak Elbow Connectors to various UD cables and 25kV class loadbreak bushings.
Estimated time: 1h 30m
Tools needed:
Hotstick, Wire brush, Crimp tool (as per lug packaging), Wire strippers
Supplies needed:
Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant (Do Not Substitute), Copper wire (No. 14 AWG / 2.5mm), Vinyl tape (if applicable), Cold shrink tube (if using sealing kit), Insulated cap (for bushing, to be removed)
- Initial Safety and Component Verification
Before starting, ensure all apparatus are de-energized. Inspect all parts for damage, correct rating, and compatibility with mating parts. Verify package contents are complete and undamaged. Check all components for proper fit with the cable and/or mating products. Test the probe by threading it into the compression lug; if resistance is encountered, check for damage and replace. Read all instructions thoroughly, have all required tools at hand, and maintain cleanliness throughout the procedure.
- Cable Training and Initial Preparation
Train the cable to ensure sufficient slack for ease of operation. Prepare neutral wires or grounding braid according to your cable type (non-jacketed, jacketed, drain wires, or copper tape shield), which may involve pulling extra cable, binding, unwrapping, removing outer jacket, or wrapping copper tape. Cut the excess cable squarely at the centerline of the bushing. If using a 200ECS or 200ECS-G sealing kit, slide the cold shrink tube onto the cable, loose end first.
- Conductor and Insulation Preparation
Remove 2-1/8” (55mm) of the shield and insulation from the cable end with a square cut, taking care not to nick the conductor. Wire brush bare aluminum conductors immediately and install the compression lug, rotating to spread inhibitor. Position the lug so its contact threaded hole aligns with the bushing bore. Crimp the lug according to the chart provided with the lug, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe excess inhibitor from the lug and cable. Remove 6-7/8” (175mm) of the insulation shield. Bevel the insulation end a maximum of 1/8” (5mm). Thoroughly clean the insulation to remove all traces of dirt or excess inhibitor.
- Elbow Assembly
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant. DO NOT SUBSTITUTE, as other lubricants may be harmful. Slide the elbow connector onto the cable with a back-and-forth twisting motion. Wipe off all excess lubricant. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the probe wrench until the wrench bends.
- Grounding Connection
Insert one end of a separate copper wire (No. 14 AWG / 2.5mm or equivalent) through the grounding eye on the elbow and twist tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Provide adequate slack in the wires for elbow operation. If using a cold shrink grounding kit, refer to the instructions supplied with that kit to complete the grounding installation.
- Final Connection to Bushing
CONFIRM THAT TRANSFORMER AND ELBOW ARE DE-ENERGIZED before proceeding. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant, only if known to be de-energized. Remove any insulated cap from the bushing by attaching a hotstick tool to its pulling eye. Securely fasten the hotstick to the loadbreak connector pulling eye. Confirm positive control of the elbow connector. Insert the probe tip approximately 2” (50mm) into the bushing. Immediately push the elbow home with a fast, firm, straight motion, using sufficient force to engage the internal lock on the elbow connector and bushing interface. DO NOT HOLD IN THIS PARTIALLY INSERTED POSITION.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.