ABB - Installation Products 262LR-D5260-S - 200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01. 200ECS Jacket Seal Included.
More images

ABB Installation Products 262LR-D5260-S 200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.890 inch to…

UPC: 075114192583


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This ABB 200 Amp, 25kV Loadbreak Elbow, SKU 262LR-D5260-S, is engineered for robust and dependable cable termination within medium voltage electrical systems. A key feature of this loadbreak elbow is its integrated test point, which facilitates safe and efficient circuit testing without the need to de-energize the system, enhancing operational safety and minimizing downtime. The design accommodates a wide range of cable sizes, with a specified cable insulation diameter range from 0.890 inches to 1.220 inches. For secure conductor connection, the elbow incorporates a bi-metal compression lug. This lug is compatible with conductor sizes of 3/0 AWG compressed stranded or 4/0 AWG solid, and has a corresponding mm² equivalent of 85.01. To ensure a complete and environmentally resistant termination, a 200ECS jacket seal is included with the product. Manufactured by ABB - Installation Products, this loadbreak elbow is built to meet the demanding requirements of utility, industrial, and commercial power distribution networks. The UNSPSC code for this item is 39121421.
  • 200 Amp, 25kV Loadbreak Elbow
  • Integrated Test Point for safe circuit testing
  • Cable Insulation Diameter: 0.890" - 1.220"
  • Bi-Metal Compression Lug: 3/0 AWG Stranded / 4/0 AWG Solid / 85.01 mm²
  • Includes 200ECS Jacket Seal

Specifications

Amperage Rating
200 A
Application
200 kV, 200 Amp
Color
Black
Conductor Range
3/0 STR/COMPR AWG , 4/0 SOL/COMPT AWG
Environmental Conditions
All Weather Conditions
Insulation
True
Material
Housing - EPDM-Rubber
Size
9.03 inch (299.4 mm) X 8.20 inch (208.3 mm) not including probe, 2.86 inch (72.6 mm) Diameter
Special Features
28kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard. Non-corrosive capacitive test point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector with Test Point
Voltage Rating
28 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
28kV, 200 Amps, Loadbreak Elbow Connector with Test Point, No Sealing Kit, .805 inch - 1.060 Inch Cable Insulation Diameter, 3/0 Stranded, 4/0 Solid Wire Size, Copper Compression Lug. Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Tube of Lubricant, Crimp Chart and Installation Instructions.

262LR-C2260

28kV, 200 Amps, Loadbreak Elbow Connector with Test Point, No Sealing Kit, .805 inch - 1.060 Inch Cable Insulation Diameter, 3/0 Stranded, 4/0 Solid Wire Size, Copper Compression Lug. Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Tube of Lubricant, Crimp Chart and Installation Instructions.
25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 4/0 Stranded Wire Size, Bi-Metal Compression Lug.

262LR-D5270

25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 4/0 Stranded Wire Size, Bi-Metal Compression Lug.
200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS-G3 Jacket Seal and Grounding Kit Included.

262LR-D5240-SG3

200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS-G3 Jacket Seal and Grounding Kit Included.
28kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #2 Stranded Wire Size, Bi-Metal Compression Lug.

262LRJS-C5220

28kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #2 Stranded Wire Size, Bi-Metal Compression Lug.
25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 2/0 Stranded Wire Size, Bi-Metal Compression Lug.

262LR-D5250

25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 2/0 Stranded Wire Size, Bi-Metal Compression Lug.
25kV 200A Loadbreak Jacket Seal Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, 2/0 Stranded Wire Size, Bi-Metal Compression Lug.

262LRJS-C5250

25kV 200A Loadbreak Jacket Seal Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, 2/0 Stranded Wire Size, Bi-Metal Compression Lug.
25kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #1 Stranded Wire Size, Bi-Metal Compression Lug.

262LRJS-C5230

25kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #1 Stranded Wire Size, Bi-Metal Compression Lug.
200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS Jacket Seal Included.

262LR-D5250-S

200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS Jacket Seal Included.

Frequently Asked Questions

What standards and certifications does the product meet?

The product is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance.

What is the current rating of the Elastimold loadbreak elbow?

The Elastimold loadbreak elbow has a current rating of 200 amps.

What voltage ratings are available for this loadbreak elbow?

The Elastimold 200 amp loadbreak elbow is available for 15 kV and 25 kV series applications.

What standards and certifications does the product meet?

The product is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance.

What is the current rating of the Elastimold loadbreak elbow?

The Elastimold loadbreak elbow has a current rating of 200 amps.

What voltage ratings are available for this loadbreak elbow?

The Elastimold 200 amp loadbreak elbow is available for 15 kV and 25 kV series applications.

What standards and certifications does the product meet?

The product is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance.

What is the current rating of the Elastimold loadbreak elbow?

The Elastimold loadbreak elbow has a current rating of 200 amps.

What voltage ratings are available for this loadbreak elbow?

The Elastimold 200 amp loadbreak elbow is available for 15 kV and 25 kV series applications.

What is the current rating of the Elastimold loadbreak elbow?

The Elastimold loadbreak elbow has a current rating of 200 amps.

How to Install the Elastimold 262LR Loadbreak Elbow Connector

This guide provides step-by-step instructions for the safe installation and initial setup of the Elastimold 262LR Loadbreak Elbow Connector, including cable preparation, assembly, grounding, and voltage testing.

Estimated time: 1h 30m

Tools needed:

Probe Wrench, Crimp tool (specific to compression lug), Wire brush, Full insulated hotstick tool, Cable cutting tool, Wire strippers, Suitable sensing device (for capacitive test points)

Supplies needed:

Elbow Connector Housing, Compression Lug, Probe, Lubricant (supplied with kit, do not substitute), Copper wire (No. 14 AWG / 2.5mm or equivalent), Appropriate connector (for neutral wires), Vinyl tape (if applicable for cable type), Cold shrink tube (if using sealing kit), Conductive copper tape (if using 200ECS-G2 kit), Silicone lubricant (for test point cap)

  1. Perform Safety Checks and Pre-Installation Verification

    DANGER: Ensure all apparatus is de-energized before beginning installation or removal of parts, except for test point caps and indicators. Verify all components are complete, undamaged, and compatible with the cable and mating products. Thread the probe into the compression lug by hand to check for resistance; replace damaged components if resistance is encountered. Gather all required tools and maintain cleanliness throughout the procedure.

  2. Train Cable and Prepare Neutral/Drain Wires

    Train the cable to ensure adequate slack for operation. Prepare the neutral or drain wires according to the cable type (non-jacketed, jacketed concentric, or jacketed with drain wires), ensuring extra length for grounding connections. Cut the cable squarely at the centerline of the bushing. If using a cold shrink sealing kit, slide the cold shrink tube onto the cable loose end first.

  3. Prepare Conductor and Insulation

    Remove 2-1/8” (55mm) of the shield and insulation from the cable end, ensuring a square cut without nicking the conductor. Wire brush bare aluminum conductors and immediately install the compression lug, rotating to spread inhibitor. Align the lug's threaded hole with the bushing bore and crimp according to the lug's chart, rotating 180 degrees for each successive crimp. Carefully wipe off excess inhibitor. Remove 6-7/8” (175mm) of the insulation shield and bevel the insulation end a maximum of 1/8” (5mm). Thoroughly clean the insulation to remove all traces of dirt or excess inhibitor.

  4. Assemble the Elbow Connector

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; do not substitute. Slide the elbow connector onto the cable using a back-and-forth twisting motion, then wipe off all excess lubricant. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten with the probe wrench until the wrench bends.

  5. Connect Grounding Wires

    Insert one end of a separate copper wire (No. 14 AWG / 2.5mm or equivalent) through the grounding eye on the elbow and twist tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack for elbow operation.

  6. Connect Elbow to Bushing

    CONFIRM that both the transformer and the elbow are DE-ENERGIZED before proceeding. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Using a full insulated hotstick tool, securely fasten it to the loadbreak connector pulling eye. Insert the probe tip approximately 2” (50mm) into the bushing, then immediately push the elbow home with a fast, firm, straight motion to engage the internal lock.

  7. Perform Voltage Test (262LR Specific)

    To test for voltage, remove the test point cap with a hotstick, peeling it off at an angle. WARNING: Use a suitable sensing device designed for capacitive test points to determine if the cable is energized. Do not use conventional voltage measuring equipment. Treat the elbow as energized until a 'no voltage' indication is confirmed by other means, as contamination or incorrect equipment can provide false readings. After testing, clean the inside surface of the cap, lubricate with silicone lubricant, and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.