ABB - Installation Products 262LR-D5230 - 25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, #1 Stranded Wire Size, Bi-Metal Compression Lug.
More images
ABB - Installation Products

262LR-D5230

UPC: 075114192248


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Overview

The ABB 262LR-D5230 is a 25kV, 200 Amp loadbreak elbow connector with an integrated test point, specifically designed for medium-voltage cable systems. This bi-metal compression lug connector is engineered to accommodate cable insulation diameters ranging from 0.890 to 1.220 inches, ensuring compatibility with a wide variety of cable types. It supports #1 AWG stranded wire, providing a secure and reliable connection for medium-voltage applications. The connector is ideal for use in underground distribution networks, switchgear, and transformer connections, where dependable performance is critical. The loadbreak feature of the 262LR-D5230 enables safe, hot-line maintenance without the need to interrupt power, significantly reducing downtime and enhancing operational efficiency. The integrated test point allows for easy voltage verification during installation or troubleshooting, ensuring that technicians can quickly and safely assess the integrity of the connection. This connector is compatible with industry-standard 200A loadbreak bushings, making it a versatile solution for various medium-voltage systems. Constructed with bi-metal materials, the 262LR-D5230 offers superior corrosion resistance and long-term conductivity, which are essential for maintaining reliable performance in harsh environments. The bi-metal compression lug ensures a high-integrity joint that minimizes the risk of failures, reducing maintenance costs and extending the lifespan of the cable system. Designed to meet the rigorous demands of medium-voltage applications, this connector is trusted by utilities and industrial facilities for its safety, reliability, and ease of maintenance. The 262LR-D5230 is engineered to deliver consistent performance in critical applications, where safety and dependability are paramount. Its robust design and high-quality construction make it a preferred choice for medium-voltage cable terminations, ensuring that power distribution systems operate efficiently and without interruption.
  • 25kV rated, 200 Amp capacity for medium-voltage systems
  • Loadbreak design enables safe hot-line maintenance without power interruption
  • Integrated test point for voltage verification during installation or troubleshooting
  • Bi-metal compression lug supports #1 AWG stranded wire and 0.890-1.220" cable insulation diameters
  • Compatible with industry-standard 200A loadbreak bushings for seamless integration

Specifications

Amperage Rating
200 A
Application
200 kV, 200 Amp
Color
Black
Conductor Range
#1 STR/COMPR AWG , 1/0 SOL/COMPT AWG
Connection Type
Compression Lug
Current Rating
200 A
Environmental Conditions
All Weather Conditions
Insulation
True
Material
Bi-Metal
Material
Housing - EPDM-Rubber
Size
9.03 inch (299.4 mm) X 8.20 inch (208.3 mm) not including probe, 2.86 inch (72.6 mm) Diameter
Size
0.890-1.220 inch Cable Insulation Diameter, #1 AWG Stranded Wire
Special Features
28kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard. Non-corrosive capacitive test point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector with Test Point
Voltage Rating
28 kV
Voltage Rating
25kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
2.2800 L
Package Weight (Metric)
1.0340 kg
25kV, 200 Amps, Loadbreak Elbow, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Conductor, Conductor Size #1 Stranded/Compressed, 1/0 Solid/Compact. With Test Point. 200ECS-G2 Jacket Seal and Grounding Kit Included. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installion Instruction Sheet and Crimp Chart.

262LR-E5230-SG2

25kV, 200 Amps, Loadbreak Elbow, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Conductor, Conductor Size #1 Stranded/Compressed, 1/0 Solid/Compact. With Test Point. 200ECS-G2 Jacket Seal and Grounding Kit Included. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installion Instruction Sheet and Crimp Chart.
6MM2 BLACK CABLE FOR DISTRIBUTION BLOCK ROW TYPE LENGTH 320MM

54211116

6MM2 BLACK CABLE FOR DISTRIBUTION BLOCK ROW TYPE LENGTH 320MM
25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, Wire Size 1/0 Stranded or 2/0 Solid. Bi-Metal Compression Lug.

262LR-D5240

25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, Wire Size 1/0 Stranded or 2/0 Solid. Bi-Metal Compression Lug.
200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01. 200ECS Jacket Seal Included.

262LR-D5260-S

200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01. 200ECS Jacket Seal Included.
25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 4/0 Stranded Wire Size, Bi-Metal Compression Lug.

262LR-D5270

25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 4/0 Stranded Wire Size, Bi-Metal Compression Lug.
200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS-G3 Jacket Seal and Grounding Kit Included.

262LR-D5240-SG3

200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS-G3 Jacket Seal and Grounding Kit Included.
28kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #2 Stranded Wire Size, Bi-Metal Compression Lug.

262LRJS-C5220

28kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #2 Stranded Wire Size, Bi-Metal Compression Lug.
25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 2/0 Stranded Wire Size, Bi-Metal Compression Lug.

262LR-D5250

25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 2/0 Stranded Wire Size, Bi-Metal Compression Lug.

Frequently Asked Questions

What cable insulation diameter does this connector support?

The connector supports cable insulation diameters ranging from 0.890 to 1.220 inches.

What wire size is compatible with this connector?

This connector is designed for #1 AWG stranded wire.

Does this connector include a test point?

Yes, the connector features an integrated test point for voltage verification.

What is the current rating of this connector?

The connector has a 200 Amp continuous current rating.

Is this connector suitable for loadbreak operations?

Yes, the connector is designed for loadbreak operations, allowing safe hot-line maintenance.

How to Install the 262LR Loadbreak Elbow Connector

A comprehensive guide for the safe installation and initial connection of the 262LR Loadbreak Elbow Connector on various UD cables, including cable preparation, lug crimping, and elbow assembly.

Estimated time: 1h 30m

Tools needed:

Probe Wrench, Wire brush, Crimp tool, Wire strippers, Hotstick (live-line tool)

Supplies needed:

Lubricant (Do Not Substitute), Copper wire (No. 14 AWG / 2.5mm), Appropriate connector (for neutral to ground), Cold shrink tube (if using sealing kit), Conductive copper tape (if using 200ECS-G2 kit), Vinyl tape (for drain wires, if applicable), HV insulated cap(s) or connector(s) (if replacing shipping covers)

  1. Perform Initial Safety Checks and Component Inspection

    DANGER: Ensure all apparatus in the work area are de-energized before beginning installation. This product must be installed only by competent personnel trained in high voltage electrical safety practices. Inspect all package contents to ensure they are complete and undamaged. Verify all components fit properly with the cable and mating products. Check the probe threads by hand-threading the probe into the compression lug; if resistance is encountered before full assembly, replace the damaged component. Remove any protective shipping covers and replace with appropriate HV insulated caps or connectors before energizing or submerging the circuit.

  2. Prepare the Cable According to Type

    Train the cable to ensure adequate slack for operation. Based on your cable type (Non-Jacketed Concentric Neutral, Jacketed Concentric Neutral, Jacketed with Drain Wires, or Jacketed Copper Tape Shield), follow the specific preparation instructions. For concentric neutral cables, pull an extra 24-26 inches (610-660mm) of cable beyond the bushing centerline and bind neutrals 7-3/4 to 8 inches (195-203mm) further back, or connect neutrals to tank ground with a jumper. Cut excess cable squarely at the bushing centerline. If using a sealing kit (e.g., 200ECS, 200ECS-G1, 200ECS-G2), slide the cold shrink tube onto the cable loose end first. For jacketed cables, remove 9-5/8 inches (240mm) of the outer jacket. For copper tape shield cables, also remove 7-1/8 inches (180mm) of the copper tape shield and wrap conductive copper tape over the end to secure it.

  3. Prepare Conductor and Insulation

    Remove the insulation shield and insulation 2-1/8 inches (55mm) from the cable end, ensuring a square cut and taking care not to nick the conductor. Wire brush any bare aluminum conductors and immediately install the compression lug. Rotate the lug to spread the inhibitor and position it so the contact threaded hole aligns with the bushing bore. Crimp the lug according to the manufacturer's chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe any excess inhibitor from the lug and cable. Remove the insulation shield 6-7/8 inches (175mm) back from the cable end, ensuring a straight, smooth, and squared cut without nicking the insulation. Bevel the insulation end a maximum of 1/8 inch (5mm). Thoroughly clean the insulation to remove all traces of dirt or excess inhibitor.

  4. Assemble the Elbow Connector

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant. DO NOT SUBSTITUTE other lubricants, as they may harm the product. Maintain cleanliness, keeping insulation free of dirt and grime. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off all excess lubricant. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the provided wrench until the wrench bends, indicating proper torque.

  5. Connect Grounding Wires

    Insert one end of a separate No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the elbow. Twist the wire tightly, taking care not to damage the eye. If the elbow was preordered with a ground wire, skip this step. Twist all neutral wires together and connect them to ground using an appropriate connector. Ensure adequate slack in the wires to allow for elbow operation.

  6. Connect the Elbow to the Bushing Plug (Loadmake Operation)

    DANGER: CONFIRM THAT BOTH THE TRANSFORMER AND THE ELBOW ARE DE-ENERGIZED before proceeding with the connection. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a full insulated 'hotstick' type live-line tool to the loadbreak connector pulling eye. Confirm positive control of the elbow connector. Remove any insulated cap from the bushing using the hotstick. Insert the probe tip approximately 2 inches (50mm) into the bushing. DO NOT HOLD IN THIS POSITION; immediately push the elbow home with a fast, firm, straight motion. Apply sufficient force to engage the internal lock on the elbow connector and bushing interface. DO NOT OPERATE BY HAND.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.