Contact for Pricing
Overview
- Voltage rating: 25/28kV
- Current rating: 200 Amps
- Cable insulation diameter range: .890 inch to 1.220 inch
- Wire size compatibility: 1/0 AWG stranded copper
- Loadbreak design with jacket seal for environmental protection
Specifications
Amperage Rating | 200 A |
Application | 25/28 kV, 200 Amp |
Color | Black |
Conductor Range | 1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG |
Environmental Conditions | All Weather Conditions |
Insulation | True |
Material | Housing - EPDM-Rubber |
Size | 11.47 inch End to Center of Installation Eye X 4.13 inch End to Bushing Datum, 2.87 inch Diameter |
Special Features | 25/28kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard. Built in Jacket Seal |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector and Jacket Seal |
Voltage Rating | 25 to 28 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

262LR-D5240
25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, Wire Size 1/0 Stranded or 2/0 Solid. Bi-Metal Compression Lug.
261LRJS-D5240
25/28kV, 200 Amp, Loadbreak Jacket Seal Elbow Connector, .890 inch - 1.220 Inch Cable Insulation Diameter, 1/0 Stranded or 2/0 Solid Wire Size, Bi-Metal Compression Lug.
261LRJS-C5240
25/28kV, 200 Amp, Loadbreak Jacket Seal Elbow Connector, .805 inch - 1.060 Inch Cable Insulation Diameter, 1/0 Stranded Wire Size, Bi-Metal Compression Lug.
261LRJS-D5250
25/28kV, 200 Amp, Loadbreak Jacket Seal Elbow Connector, .890 inch - 1.220 Inch Cable Insulation Diameter, 2/0 Stranded or 3/0 Solid Wire Size, Bi-Metal Compression Lug.
261LRJS-C5230
25/28kV, 200 Amp, Loadbreak Jacket Seal Elbow Connector, .805 inch - 1.060 Inch Cable Insulation Diameter, #1 Stranded Wire Size, Bi-Metal Compression Lug.
261LRJS-C5220
25/28kV, 200 Amp, Loadbreak Jacket Seal Elbow Connector, .805 inch - 1.060 Inch Cable Insulation Diameter, #2 Stranded Wire Size, Bi-Metal Compression Lug.
261LR-D5270
25/28kV, 200 Amp, Loadbreak Elbow Connector, .890 inch - 1.220 Inch Cable Insulation Diameter, 4/0 Stranded Wire Size, Bi-Metal Compression Lug.Frequently Asked Questions
What are the voltage ratings for this elbow?
The enhanced Elastimold 200 amp loadbreak elbow is available for 15 kV and 25 kV series applications.
How does the elbow reduce life cycle costs?
It is optimized for switching operations, provides lifetime ease of operation and non-stick performance with Elastimold bushings, and has an improved seal system.
What flexibility enhancements does the elbow offer?
It offers additional sizes, improved wider cable ranges, an easy order system, and an optional integral jacket seal.
What is the significance of RUS acceptance?
RUS acceptance from the U.S. Department of Agriculture authorizes its use in rural infrastructure construction and improvements.
What standards and certifications does the elbow meet?
The enhanced Elastimold 200 amp loadbreak elbow is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance.
How does the elbow ensure a no-stick interface?
The elbow provides a no-stick interface when used with Elastimold bushings, a feature tested by NEETRAC.
What safety features does the elbow include?
It features improved insulation for 15 kV elbows, rigid probe support, a no-stick interface with Elastimold bushings, a robust stainless-steel pulling eye, and dual grounding eye positions.
What is the Elastimold 200 amp loadbreak elbow?
It is an enhanced 200 amp loadbreak elbow for 15 kV and 25 kV series, designed for easier switching operations.
What is the Elastimold 200 amp loadbreak elbow?
It is an enhanced 200 amp loadbreak elbow for 15 kV and 25 kV series, designed for easier switching operations.
What are the voltage ratings for this elbow?
The enhanced Elastimold 200 amp loadbreak elbow is available for 15 kV and 25 kV series applications.
How to Install 261LRJS/262LRJS Loadbreak Elbow Connectors
This guide provides step-by-step instructions for the safe installation and assembly of 261LRJS and 262LRJS Loadbreak Elbow Connectors with jacket seals on UD cable, including cable preparation and neutral connection.
Estimated time: 1h 30m
Tools needed:
Probe wrench, Cable cut back template, Wire brush, Crimp tool, Wire strippers, Utility knife
Supplies needed:
Elbow connector housing, Compression lug, Probe, Lubricant (supplied), 3 sealing strips (mastic), Vinyl tape, Copper wire (No. 14 AWG / 2.5mm or equivalent), Appropriate ground connector
- Perform Initial Safety Checks and Component Verification
DANGER: All apparatus must be de-energized during installation. This product should only be installed by competent personnel trained in high voltage electrical equipment safety. Failure to follow instructions will result in serious injury or death. Check all package contents for completeness and damage. Verify all components fit properly with the cable and mating products. Thread the probe into the compression lug to check for resistance; if encountered, inspect for damage and replace components. Ensure all required tools are at hand and maintain cleanliness. If installing a 262LRJS, lubricate and install the test point cap if not already present.
- Train and Prepare Cable Jacket and Neutral Wires
Train the cable to ensure sufficient slack for ease of operation. Pull extra cable 24-26 inches beyond the bushing centerline, then mark and remove the outer jacket 7-3/4 to 8 inches further back from the tape mark. Unwrap the neutral wires back past the bushing centerline. Cut the excess cable squarely at the bushing centerline. Wrap one mastic strip, stretching slightly, around the jacket. Bend all neutral wires straight back over the mastic and along the cable, pressing them into the mastic. Wrap a second mastic strip completely around the outer jacket, overlapping the imbedded neutral wires. Use a third strip if needed to build up the outer diameter. Cover all mastic with vinyl tape.
- Prepare Cable Insulation and Conductor
Remove the insulation shield and insulation from the cable end, cutting squarely and taking care not to nick the conductor. Wire brush bare aluminum conductors and immediately install the compression lug, rotating to spread inhibitor. Position the lug so the contact threaded hole aligns with the bushing bore. Crimp according to the chart provided with the lug, rotating 180 degrees for each successive crimp. Carefully wipe excessive inhibitor from the outside of the lug and cable. Remove the insulation shield as shown in the diagram, and bevel the insulation end a maximum of 1/8 inch. Thoroughly clean the insulation to remove all traces of conductive residue.
- Assemble the Elbow Connector
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant. DO NOT SUBSTITUTE other lubricants, as they may be harmful. Keep the insulation clean. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off all excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the probe wrench until the wrench bends, indicating proper torque.
- Connect the Concentric Neutral
Insert one end of a separate copper wire (No. 14 AWG / 2.5mm or equivalent) through the grounding eye on the elbow. Twist the wire tightly, taking care not to damage the eye. Pull the hood over the concentric neutral seal area on the cable by pulling the tabs or rolling the seal down. Twist all neutral wires together and connect them to ground using an appropriate connector. Ensure adequate slack in the wires for future elbow operation.
- Connect the Elbow to the Mating Bushing
Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. WARNING: LUBRICATE ONLY IF THE TRANSFORMER AND ELBOW ARE KNOWN TO BE DE-ENERGIZED. Securely fasten a hotstick to the loadbreak connector pulling eye. Confirm positive control of the elbow connector. Insert the probe tip approximately 2 inches (50mm) into the bushing. Immediately push the elbow home with a fast, firm, straight motion, using sufficient force to engage the internal lock on the elbow connector and bushing interface. DO NOT OPERATE BY HAND.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.