ABB Installation Products 261LR-D5270 25/28kV, 200 Amp, Loadbreak Elbow Connector, .890 inch - 1.220 Inch Cable Insulation…
UPC: 075114191098
Contact for Pricing
Minimum Qty: 12
Multiplier: 12
*Contact for lower quantities*
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 25/28kV Voltage Rating
- 200 Amp Current Rating
- Accommodates .890" - 1.220" Cable Insulation Diameter
- Designed for 4/0 Stranded Wire Size
- Bi-Metal Compression Lug for Reliable Connections
Specifications
Amperage Rating | 200 A |
Application | 25/28 kV, 200 Amp |
Color | Black |
Conductor Range | 4/0 STR/COMPR AWG , 250 kcmil |
Connection Type | LoadBreak Elbow Connector |
Current Rating | 200 A |
Environmental Conditions | All Weather Conditions |
Insulation | True |
Material | Housing - EPDM-Rubber |
Material | Bi-Metal Compression Lug |
Size | 9.03 inch (299.4 mm) X 7.89 inch (200.4 mm) not including probe, 2.86 inch (72.6 mm) Diameter |
Size | 0.890 inch - 1.220 Inch Cable Insulation Diameter, 4/0 Stranded Wire Size |
Special Features | 25/28kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector |
Voltage Rating | 25 to 28 kV |
Voltage Rating | 25/28kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 2.2800 L |
Package Weight (Metric) | 1.0340 kg |

162LR-C5270-S
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.
261LR-D5270-S
25/28kV, 200 Amp, Loadbreak Elbow without Test Point, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.
261LR-D5240
25/28kV, 200 Amp, Loadbreak Elbow Connector, .890 inch - 1.220 Inch Cable Insulation Diameter, 1/0 Stranded Wire Size, Bi-Metal Compression Lug.
261LR-D5230
25/28kV, 200 Amp, Loadbreak Elbow Connector, .890 inch - 1.220 Inch Cable Insulation Diameter, #1 Stranded Wire Size, Bi-Metal Compression Lug.
261LR-C5270
25/28kV, 200 Amp, Loadbreak Elbow Connector, .805 inch - 1.060 Inch Cable Insulation Diameter, 4/0 Stranded or 250 kcmil Solid Wire Size, Bi-Metal Compression Lug.
261LR-C5240
25/28kV, 200 Amp, Loadbreak Elbow Connector, .805 inch - 1.060 Inch Cable Insulation Diameter, 1/0 Stranded Wire Size, Bi-Metal Compression Lug.
261LR-C5250
25/28kV, 200 Amp, Loadbreak Elbow Connector, .805 inch - 1.060 Inch Cable Insulation Diameter, 2/0 Stranded or 3/0 Solid Wire Size, Bi-Metal Compression Lug.
261LR-C5240-CEPA-H
25/28kV, 200 Amp, Loadbreak Elbow Connector, .805 inch - 1.060 Inch Cable Insulation Diameter, 1/0 Stranded Wire Size, Bi-Metal Compression Lug. CEPA-HFrequently Asked Questions
Does the elbow offer multiple grounding positions?
Yes, the enhanced design includes dual grounding eye positions.
What material is the pulling eye made from?
The pulling eye is made of robust stainless steel, which promotes durable hotstick control.
What is the function of the rigid probe support?
The internal rigid probe support ensures proper switching and easy probe installation.
Is an integral jacket seal available for the elbow?
Yes, the enhanced Elastimold 200 amp loadbreak elbow offers an optional integral jacket seal.
Is the elbow approved for rural infrastructure projects?
Yes, it has Rural Utilities Service (RUS) acceptance from the U.S. Department of Agriculture (USDA), authorizing its use in rural infrastructure construction.
What standards and certifications does the elbow meet?
The product is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance.
What are the voltage ratings for this loadbreak elbow?
The Elastimold 200 amp loadbreak elbow is designed for 15 kV and 25 kV series applications.
What is the ABB Elastimold product?
It is an enhanced 200 amp loadbreak elbow available for 15 kV and 25 kV series applications.
What material is the pulling eye made from?
The pulling eye is made of robust stainless steel, which promotes durable hotstick control.
What are the voltage ratings for this loadbreak elbow?
The Elastimold 200 amp loadbreak elbow is designed for 15 kV and 25 kV series applications.
How to Install Elastimold 261LR/262LR Loadbreak Elbow Connectors
This guide provides step-by-step instructions for the safe installation and initial setup of Elastimold 261LR and 262LR Loadbreak Elbow Connectors on various UD cables. It covers cable preparation, connector assembly, and grounding procedures.
Estimated time: 1h 30m
Tools needed:
Wire strippers/Cable knife, Wire brush, Crimp tool (specific to lug), Probe wrench, Vinyl tape
Supplies needed:
Elastimold 261LR or 262LR Elbow Connector Kit (includes housing, compression lug, probe, lubricant), UD Cable (appropriate type and size), Copper wire (No. 14 AWG / 2.5mm or equivalent), Grounding connector (for neutral/ground wires), Cold shrink sealing kit (e.g., 200ECS, if applicable), Conductive copper tape (if using 200ECS-G2 kit)
- Ensure Safety and Prepare Cable for Training
DANGER: All apparatus must be de-energized during installation or removal of parts. Failure to follow this instruction will result in serious or fatal injury. Inspect all parts for damage, rating, and compatibility with mating parts. Train the UD cable to ensure adequate slack for ease of operation. Depending on your cable type (non-jacketed, jacketed concentric neutral, jacketed with drain wires, or jacketed copper tape shield), prepare the neutral or ground wires by pulling extra length (24-26 inches beyond bushing centerline) or removing the outer jacket (9-5/8 inches back from tape mark/bushing centerline). Cut the excess cable squarely at the centerline of the bushing. If using a cold shrink sealing kit, slide the cold shrink tube onto the cable loose end first at this stage.
- Prepare Cable End and Install Compression Lug
Remove the cable shield and insulation 2-1/8 inches (55mm) from the cable end, ensuring a square cut without nicking the conductor. Wire brush the bare aluminum conductors thoroughly. Immediately install the compression lug onto the conductor, rotating it to spread the inhibitor. Position the compression lug so its contact threaded hole aligns with the bushing bore. Refer to the crimp chart provided with the compression lug for recommended crimp tool information. Start crimping at the crimp line mark and rotate 180 degrees for each successive crimp. Carefully wipe any excess inhibitor from the outside of the lug and cable. Remove the insulation shield 6-7/8 inches (175mm) from the cable end, ensuring a straight, smooth, and squared cut without cutting or nicking the insulation. Bevel the insulation end a maximum of 1/8 inch (5mm). Thoroughly clean the insulation to remove all traces of dirt or excess inhibitor.
- Assemble Elbow Connector
Lubricate the cable insulation and the inside of the elbow housing with the lubricant supplied in the kit. DO NOT SUBSTITUTE other lubricants, as they may be harmful to the product. Maintain cleanliness of the insulation. Slide the elbow connector onto the cable using a back-and-forth twisting motion until it is fully seated. Wipe off all excess lubricant. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, taking care not to cross-thread. The probe should turn freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends, indicating proper torque.
- Ground the Elbow Connector
Insert one end of a separate copper wire (No. 14 AWG / 2.5mm or equivalent) through the grounding eye on the elbow. Twist the wire tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Ensure adequate slack in the wires to allow for elbow operation. If using a cold shrink grounding kit, refer to the specific instructions supplied with that kit to complete the grounding installation.
- Prepare for Connection to Bushing Plug
CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED before proceeding. Lubricate the receptacle portion of the elbow connector and the mating bushing with the lubricant supplied in the kit. The elbow is now ready for connection to the bushing plug. Note: Loadmake and Loadbreak operations must be performed with a full insulated 'hotstick' type tool and not by hand. Consult your company’s safe work practices for required tool length and operating procedures.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.