ABB Installation Products 252LR-D5240 15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter…
UPC: 075114345965
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15/25 kV, 200 Amp rated deadbreak elbow connector
- Capacitive test point for safe circuit verification without de-energization
- Bi-metal lug compatible with 240-1/0 AWG stranded/compressed and 2/0 AWG solid/compact conductors
- Cable insulation diameter range: 0.890-1.220 inches (22.61-30.99mm)
- Meets IEC 60502-4 and CEN 629.1 S2 standards
- Kit includes elbow housing, lug, probe, wrench, bail assembly, V.D. cap, lubricant, crimp chart, and instructions
- Dimensions: 5.454 x 7.531 inches, 2.097-inch diameter
- Robust stainless-steel pulling eye and dual grounding eye positions
Specifications
Amperage Rating | 200 A |
Application | 15/25kV, 200 Amp Deadbreak Connector |
Color | Black |
Conductor Range | 1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG |
Connection | Compression |
Connection Type | Deadbreak Elbow Connector |
Current Rating | 200 A |
Environmental Conditions | Fully Submersible |
Insulation | True |
Length | 7.531 in |
Length | 191.2874 mm |
Material | Housing - EPDM-Rubber |
Material | Polyethylene |
Mounting Type | Bail Assembly |
Series | 252LR |
Size | 5.454 x 7.531 inches, 2.097 inch diameter |
Special Features | Fully Shielded, fully Submersible Molded Rubber Housing. Provision for Hot Stick Operation. Non-Corrosive, Capacitive Test Point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Elbow Connector with Test Point |
Voltage Rating | 15 to 25 kV |
Voltage Rating | 15/25 kV |
Width | 5.454 in |
Width | 138.5316 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

261LRJS-C5240
25/28kV, 200 Amp, Loadbreak Jacket Seal Elbow Connector, .805 inch - 1.060 Inch Cable Insulation Diameter, 1/0 Stranded Wire Size, Bi-Metal Compression Lug.
252LR-D5260
15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.890-1.220 inches (22.61-30.99mm), Bi-Metal Lug, Conductor Size 260 - 3/0 Stranded/Compressed, 4/0 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter.
252LR-C5260
15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.805-1.060 inches (20.45-26.92mm), Bi-Metal Lug, Conductor Size 260 - 3/0 Stranded/Compressed, 4/0 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter.
252LR-C5270-S
15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.805-1.060 inches (20.45-26.92mm), Bi-Metal Lug, Conductor Size 270 - 4/0 Stranded/Compressed, 250kcmil Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter. Cold-Shrinkable Jacket Seal.
K656LR-F0210-SG3
15/25kV, 600 Amp, DeadBreak, Elbow with Test Point (includes Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation .640-.820 inches, Aluminum Compression Lug, Conductor Size #2 Compact/Solid, Cold-Shrinkable Seal with Copper Braid and Constant Force Spring
252LR-D5270
15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.890-1.220 inches (22.61-30.99mm), Bi-Metal Lug, Conductor Size 270 - 4/0 Stranded/Compressed, 250kcmil Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter.
K656LR-G0220
15/25kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Cable Insulation .760 to .950 inch. Aluminum Compression Lug, Conductor Size #2 Stranded/Compressed or #1 Compact/Solid
K656LR-G0230
15/25kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Cable Insulation .760 to .950 inch. Aluminum Lug, Conductor Size #1 Stranded/Compressed or 1/0 Compact/SolidFrequently Asked Questions
Does the connector include a test point?
Yes, the 252LR Elbow Connector is equipped with an integral, non-corrosive, capacitive test point.
Can the connector be operated with hot stick tools?
Yes, the connector includes provisions for de-energized operation using standard hot stick tools.
Is the elbow connector designed for submersible applications?
Yes, the 252LR Elbow Connector features a fully shielded and fully submersible molded rubber housing.
Are there recommended safety accessories for the elbow connector?
Yes, a sealing and grounding kit is highly recommended for safety purposes with the deadbreak elbow.
Which industry standard does the 252LR Elbow Connector meet?
The 252LR Elbow Connector meets ANSI/IEEE Standard 386, Latest Revision.
What are the operating voltage limits for the 25kV class?
For the 25kV class, the maximum phase-to-ground operating voltage is 15.2kV, and the maximum phase-to-phase is 26.3kV.
What are the operating voltage limits for the 15kV class?
For the 15kV class, the maximum phase-to-ground operating voltage is 8.3kV, and the maximum phase-to-phase is 14.4kV.
What are the key features of the 252LR Elbow Connector?
It is a fully shielded, submersible molded rubber housing with 100% peroxide-cured construction. It includes provisions for hot stick operation and a capacitive test point.
What is the voltage and current rating of this connector?
The connector is rated for 15/25kV voltage classes and has a continuous current rating of 200 Amps.
Does the connector include a test point?
Yes, the 252LR Elbow Connector is equipped with an integral, non-corrosive, capacitive test point.
How to Install 252LR Deadbreak Elbow Connectors
This guide provides step-by-step instructions for installing the 252LR Deadbreak Elbow Connector, designed to terminate UD cable with concentric neutral and semi-con shielding, and connect to 25kV class deadbreak bushings.
Estimated time: 1h 30m
Tools needed:
Wrench, Crimp tool, Wire brush, Hot stick, Wire strippers, Suitable sensing device (for capacitive test points)
Supplies needed:
Elbow Connector Housing, Compression Lug, Probe, Probe Contact, Lubricant (supplied), Hold-down Bail, UD cable (concentric neutral and semi-con shielding), No. 14 AWG / 2.5mm copper wire, Appropriate connector (for grounding), HV insulated cap(s) or connector(s) (if shipping covers are removed), Test point cap (if not installed)
- Review Safety and Perform Pre-Installation Checks
**DANGER: All apparatus must be de-energized during installation or removal of part(s). Do not touch or move energized products in the work area. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment.** Inspect all parts for damage, rating, and compatibility with mating parts. Check the elbow housing cable entrance size and compression lug size for proper fit with the cable. Thread the probe into the compression lug to check threads; if resistance is encountered, check for damage and replace the component. Ensure all required tools are at hand and maintain cleanliness throughout the procedure. If a test point cap is not installed, lubricate the cap and test point, then install the cap.
- Train the Cable
Train the UD cable as shown in the diagram to ease operation, ensuring a minimum of 20 inches (508.0mm) beyond the end of the cable pad mount transformer. Cut any excess cable squarely at the center line of the bushing.
- Prepare the Cable End
Unwrap and bind concentric neutral wires 8-1/2 inches (216.0mm) back from the end of the cable. Remove the shield and insulation from the cable end, cutting squarely without nicking the conductor. Wire brush bare aluminum conductors and immediately install the compression lug, rotating to spread inhibitor. Position the compression lug so the contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe excessive inhibitor from the outside of the lug and cable. Remove the semi-con shield as shown, and bevel the insulation end 1/8 inch (3.2mm) maximum. Thoroughly clean the insulation to remove all traces of conductive residue.
- Assemble the Elbow Connector
Clean and lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; do not substitute. Slide the elbow connector onto the cable with a back and forth twisting motion, then wipe off all excess silicone lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, taking care not to cross-thread. Tighten with a wrench until the wrench bends.
- Install the Hold-down Bail
Place the hold-down bail into the hold-down bracket. Compress the bail and insert it securely into the brackets.
- Connect the Concentric Neutral
Using a separate No. 14 AWG (2.5mm) copper wire or equivalent, insert one end through the grounding eye on the elbow. Twist it tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack in the wires for elbow operation.
- Connect Elbow to Bushing
Clean the receptacle portion of the elbow connector and the mating bushing, and lubricate with the supplied lubricant. **LUBRICATE ONLY IF THE TRANSFORMER AND ELBOW ARE KNOWN TO BE DE-ENERGIZED.** Use a fully insulated hot stick to place the elbow on the bushing. **DO NOT OPERATE BY HAND. DO NOT SEPARATE IF ENERGIZED.**
- Secure the Elbow with Bail
Pull the hold-down bail up over the crown or top of the elbow so that the eyebolt on the bail is directly over the operating eye. Tighten down on the elbow locator by turning the eyebolt in a clockwise direction. Adjust the nut on the eyebolt until it allows the eyebolt to seat securely in the locator. The nut should act as a stop to prevent the eyebolt from applying excessive force on the elbow. Once the nut is in its final position, it will not need to be readjusted when removing and replacing the elbow.
- Perform Voltage Test (Optional)
If equipped with an integral capacitance test point, remove the test point cap with a hotstick, peeling it off at an angle. **WARNING: The voltage test point is a capacitance device and not directly connected to the conductor. Do not use conventional voltage measuring equipment. Follow the manufacturer’s directions for a suitable sensing device made for capacitive test points to determine if the cable is energized. Contamination, moisture, dirt, or wrong equipment can provide a false "no voltage" indication. Treat the elbow as energized until the "no voltage" indication is confirmed by other means to prevent serious or fatal injury.** After testing, clean and lubricate the inside surface of the cap with silicone grease and replace it on the test point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.