ABB - Installation Products K656LR-G0230 - 15/25kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Cable Insulation .760 to .950 inch. Aluminum Lug, Conductor Size #1 Stranded/Compressed or 1/0 Compact/Solid
ABB - Installation Products

K656LR-G0230

UPC: 783786414734


Documents & Media
Installation InstructionsManufacturer Product Website

Contact for Pricing

Overview

The ABB K656LR-G0230 15/25kV 600 Series Deadbreak Elbow with Test Point is a deadbreak connector designed for medium-voltage cable systems. It supports conductor sizes from #1 stranded/compressed to 1/0 compact/solid with cable insulation between .760 and .950 inches. The unit includes an insulated plug, cap, stud, lug, and cable adapter, all constructed with an aluminum lug for durability and conductivity. This deadbreak elbow is rated for 15/25kV applications, making it suitable for utility, industrial, and commercial power distribution systems. The integrated test point allows for safe voltage verification without disconnecting the system, reducing downtime during maintenance or troubleshooting. The 600 Series design ensures compatibility with standard 600A deadbreak interfaces, providing a reliable connection for medium-voltage cables. The K656LR-G0230 is manufactured by ABB, a leader in electrical and automation technologies, ensuring compliance with industry standards for safety and performance. Its compact design and robust construction make it ideal for underground and overhead cable terminations where space and reliability are critical.
  • 15/25kV voltage rating for medium-voltage applications
  • Supports #1 stranded/compressed or 1/0 compact/solid conductors
  • Cable insulation range: .760 to .950 inches
  • Integrated test point for safe voltage verification
  • Includes insulated plug, cap, stud, lug, and cable adapter

Specifications

Amperage Rating
600 A
Application
15/25kV, 600 Amp Deadbreak Elbow Connection
Color
Black
Conductor Range
#1 STR/COMPR AWG , 1/0 SOL/COMPT AWG
Environmental Conditions
Fully Submersible
Insulation
True
Length
13 in
Length
330.2 mm
Material
Housing - EPDM-Rubber
Special Features
Fully Shielded, Fully Submersible Molded Rubber Housing. 100 percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Materials. Can be Easily Connected or Disconnected using Standard Hand Tools and Equipment in a De-Energized State. Non-Corrosive, Capacitive Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector with Test Point
Voltage Rating
25 kV
Width
10.36 in
Width
263.144 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
6.6500 L
Package Weight (Metric)
3.0160 kg
600 Amp, 15/25kV, Deadbreak, Straight Receptacle with Test Point, Cable Insulation Diameter .850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #1 or Compacted Solid 1/0.

K656YSR-H0230

600 Amp, 15/25kV, Deadbreak, Straight Receptacle with Test Point, Cable Insulation Diameter .850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #1 or Compacted Solid 1/0.
6MM2 BLACK CABLE FOR DISTRIBUTION BLOCK ROW TYPE LENGTH 320MM

54211116

6MM2 BLACK CABLE FOR DISTRIBUTION BLOCK ROW TYPE LENGTH 320MM
600 Amp, 15/25kv, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation .850 to 1.050 inch. Aluminum Lug, Conductor Size 4/0 stranded/compressed or 250 Compact/solid. With Cold Shrinkable Seal with Copper Braid and Constant Force Spring.

K656LR-H0270-SG3

600 Amp, 15/25kv, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation .850 to 1.050 inch. Aluminum Lug, Conductor Size 4/0 stranded/compressed or 250 Compact/solid. With Cold Shrinkable Seal with Copper Braid and Constant Force Spring.
600 Amp, 15/25kv, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation .760 to .950 inch. Aluminum Lug, Conductor Size 2/0 stranded/compressed or 3/0 Compact/solid. With Cold Shrinkable Seal with Copper Braid and Constant Force Spring.

K656LR-G0250-SG3

600 Amp, 15/25kv, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation .760 to .950 inch. Aluminum Lug, Conductor Size 2/0 stranded/compressed or 3/0 Compact/solid. With Cold Shrinkable Seal with Copper Braid and Constant Force Spring.
600 Amp, 15/25kv, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation .640 to .820 inch. Aluminum Lug, Conductor Size 1/0 stranded/compressed or 2/0 Compact/solid. With Cold Shrinkable Seal with Copper Braid and Constant Force Spring.

K656LR-F0240-SG3

600 Amp, 15/25kv, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation .640 to .820 inch. Aluminum Lug, Conductor Size 1/0 stranded/compressed or 2/0 Compact/solid. With Cold Shrinkable Seal with Copper Braid and Constant Force Spring.
15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.575-0.740 inches (14.61-18.80mm), Bi-Metal Lug, Conductor Size 220 - #2 Stranded/Compressed, #1 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter.

252LR-A5220

15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.575-0.740 inches (14.61-18.80mm), Bi-Metal Lug, Conductor Size 220 - #2 Stranded/Compressed, #1 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter.
15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.575-0.740 inches (14.61-18.80 mm), Bi-Metal Lug, Conductor Size 210 - #3 Stranded/Compressed, #2 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter.

252LR-A5210

15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.575-0.740 inches (14.61-18.80 mm), Bi-Metal Lug, Conductor Size 210 - #3 Stranded/Compressed, #2 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter.
15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.575-0.740 inches (14.61-18.80mm), Bi-Metal Lug, Conductor Size 230 - #1 Stranded/Compressed, 1/0 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter.

252LR-A5230

15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.575-0.740 inches (14.61-18.80mm), Bi-Metal Lug, Conductor Size 230 - #1 Stranded/Compressed, 1/0 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter.

Frequently Asked Questions

What voltage rating does this deadbreak elbow support?

The K656LR-G0230 supports a 15/25kV voltage rating for medium-voltage applications.

What conductor sizes are compatible with this elbow?

The elbow supports #1 stranded/compressed or 1/0 compact/solid conductor sizes.

What is the cable insulation range for this connector?

The cable insulation range is between .760 and .950 inches.

Does this elbow include a test point?

Yes, the K656LR-G0230 features an integrated test point for voltage verification.

What materials are used in the lug construction?

The lug is constructed from aluminum for durability and conductivity.

Is this deadbreak elbow compatible with 600A interfaces?

Yes, the 600 Series design ensures compatibility with standard 600A deadbreak interfaces.

How to Install K655/K675LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe installation and setup of K655/K675LR and 655/675LR deadbreak elbow connectors, ensuring fully shielded and submersible cable connections to high voltage apparatus.

Estimated time: 1h 30m

Tools needed:

Cable cutter, Wire strippers, Utility knife, Crimping tool, Torque wrench, Wrench/Socket set, Hotstick, Wire brush, Suitable voltage sensing device

Supplies needed:

K655/K675LR Deadbreak Elbow Connector kit (Elbow, Cable Adapter, Compression Lug, Insulating Plug, Lubricant, Stud Prepack), Cleaning solution/cloth, No. 14 AWG Copper wire (for grounding), Suitable grounding connector, Waterproofing material (for cable jacket), HV insulated cap(s) or connector(s) (if replacing shipping covers)

  1. Ensure Safety and Inspect Components

    DANGER: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products in the work area. Failure to follow these instructions will result in damage to the product and serious or fatal injury. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Inspect all parts for damage, rating, and compatibility with mating parts. Check the package contents to ensure they are complete and undamaged. Remove any protective shipping covers and replace with appropriate HV insulated caps or connectors before submerging or energizing the circuit.

  2. Prepare the Cable for Connection

    Assemble the cable in its final position with enough slack to allow for elbow removal. For concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4 inches (45mm) from the centerline of the mating product. Clean the outer surface of the cable for a distance of 24 inches (610mm) or up to the bent-back concentric neutral wires. Follow the specific cable preparation instructions (e.g., outer jacket removal, shield connection) provided with any grounding device (20MA/21MA, 600ECS) or cable shield adapter (10TL) if being used. Otherwise, prepare the cable as shown in the diagrams for jacketed or non-jacketed cable types, removing the outer jacket (if applicable) and exposing the semi-con shield and cable insulation according to the specified lengths (e.g., 9-3/4 inches, 10-3/4 inches, 12-3/4 inches from the tape marker).

  3. Install Cable Adapter and Expose Conductor

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and then lubricate the cable insulation, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker. Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. The length of the exposed conductor must be between 4-1/4 inches and 4-9/16 inches (108mm-116mm); otherwise, redo the assembly.

  4. Crimp the Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor and immediately fully insert it into the compression lug. Measure the 'Check Dimension' before crimping; this dimension should be less than 6-3/8 inches. Crimp the compression lug following the instructions supplied with the lug. Wipe all excess inhibitor from the compression lug and cable adapter surface after crimping. The distance from the end of the compression lug to the cable adapter after crimping should be between 6-3/8 inches to 7-1/8 inches (162mm-181mm); otherwise, redo the assembly.

  5. Install the Elbow Connector

    Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter is still flush with the tape marker; if not, reposition the cable adapter. Remove the tape marker.

  6. Connect the Elbow to Mating Products

    WARNING: DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. DO NOT ENERGIZE WHILE DISCONNECTED. Remove protective caps from the elbow and the mating part. Hand tighten the threaded stud supplied with the elbow into the mating part, if the mating part is not already equipped with a stud. Clean and lubricate both the elbow and the mating part with the supplied lubricant, ensuring surfaces remain clean. Push the elbow onto the mating part, aligning the hole in the compression lug with the stud on the mating part. For the opposite end of the elbow, clean and lubricate the mating part, then insert it into the elbow. Engage the threads and hand tighten, then torque the mating part according to its specific instructions.

  7. Install Insulating Plug and Voltage Detection Cap (if applicable)

    If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap. Place the cap on the elbow and push down hard until it snaps into place. Follow the voltage test directions after completing all installation steps.

  8. Ground the Cable Shield and Waterproof Jacket

    Insert one end of a piece of wire with ampacity at least equivalent to No. 14 AWG Copper through the grounding eye and twist to make a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. The shield of the cable must be grounded; ground it according to the instructions supplied with the grounding device. If no grounding device is used, ground the shield through an alternate method. It is also recommended to waterproof the cable jacket at this point to prevent moisture from entering the cable.

  9. Perform Voltage Test

    The ELASTIMOLD deadbreak elbow connector is equipped with an integral capacitance test point. Remove the test point cap with a hotstick, peeling it off at an angle rather than pulling directly. WARNING: The voltage test point is a capacitance device and is NOT directly connected to the conductor. Do not use conventional voltage measuring equipment. Follow the manufacturer’s directions for the meter used. Test with a suitable sensing device, made for use with separable connectors manufactured with capacitive test points, to determine if the cable is energized. Contamination, moisture, dirt, or using the wrong equipment can provide a false 'no voltage' indication. To prevent serious or fatal injury, treat the elbow as energized until the 'no voltage' test point indication is confirmed by other means. After voltage detection, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.