ABB Installation Products 252LR-B5270-S 15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter…
UPC: 075114345866
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15/25kV voltage class, 200 Amp continuous rating
- Deadbreak design for safe connection/disconnection under de-energized conditions
- Built-in test point for safe diagnostic testing without system shutdown
- Bi-metal lug supports copper and aluminum conductors (270-4/0 AWG stranded, 250 kcmil solid)
- Cold-shrinkable jacket seal for environmental protection
- Kit includes elbow housing, lug, probe, wrench, bail assembly, V.D. cap, lubricant, crimp chart, and instructions
Specifications
Amperage Rating | 200 A |
Application | 15/25kV, 200 Amp Deadbreak Connector |
Color | Black |
Conductor Range | 4/0 STR/COMPR AWG , 250 kcmil |
Connection | Compression |
Environmental Conditions | Fully Submersible |
Insulation | True |
Length | 7.531 in |
Length | 191.2874 mm |
Material | Housing - EPDM-Rubber |
Special Features | Fully Shielded, fully Submersible Molded Rubber Housing. Provision for Hot Stick Operation. Non-Corrosive, Capacitive Test Point. Jacket Seal |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Elbow Connector with Test Point |
Voltage Rating | 15 to 25 kV |
Width | 5.454 in |
Width | 138.5316 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

162LR-C5270-S
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.
252LR-C5230
15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.805-1.060 inches (20.45-26.92mm), Bi-Metal Lug, Conductor Size 230 - #1 Stranded/Compressed, 1/0 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter.
252LR-B5230
15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635-0.905 inches (16.13-22.99mm), Bi-Metal Lug, Conductor Size 230 - #1 Stranded/Compressed, 1/0 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter.
252LR-B5270
15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635-0.905 inches (16.13-22.99mm), Bi-Metal Lug, Conductor Size 270 - 4/0 Stranded/Compressed, 250kcmil Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter.
252LR-C5250
15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.805-1.060 inches (20.45-26.92mm), Bi-Metal Lug, Conductor Size 250 - 2/0 Stranded/Compressed, 3/0 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter.
K675LR-K2330
15/25kV, 900 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter K - 1.090-1.310 inch (27.689-33.274mm). Copper Compression Lug. Conductor Size 330 - Stranded/Compressed 500 kcmil, Solid/Compact 600 kcmil, mmsq 250/300.
162LR-B5250-SG2
200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
162LR-D2270
15kV, 200 Amps, Loadbreak Elbow Connector with Test Point. Cable Insulation Diameter .890-1.220 inches (22.61-30.99mm). Copper Compression Lug. Conductor Size 270 - 4/0 Stranded/Compressed or 250 kcmil Solid/Compact or 107.20 mmsq. No Sealing Kit. Includes Elbow Housing, Compression Lug, Probe, Probe Wrench, Tube of Lubricant, Crimp Chart, V.D. Cap - Peroxide, and Installation Instructions.Frequently Asked Questions
What is the voltage rating for this deadbreak elbow connector?
The ABB 252LR-B5270-S deadbreak elbow connector is rated for 15/25kV.
What conductor sizes can this connector accommodate?
This connector is designed for conductor sizes 270 - 4/0 AWG stranded/compressed and 250 kcmil solid/compact.
What is the range of cable insulation diameters supported?
The connector supports cable insulation diameters from 0.635 to 0.905 inches (16.13-22.99mm).
Does this connector include a test point?
Yes, the ABB 252LR-B5270-S features a built-in test point for convenient testing.
What type of lug is used in this elbow connector?
This elbow connector utilizes a bi-metal lug, suitable for both copper and aluminum conductors.
What components are included in the kit?
The kit includes the elbow connector housing, lug, probe, probe wrench, bail assembly, V.D. cap, lubricant tube, crimp chart, and installation instructions.
How to Install Elastimold 252LR Deadbreak Elbow Connectors
This guide provides step-by-step instructions for installing the Elastimold 252LR Deadbreak Elbow Connector, designed to terminate UD cable and connect to 25kV class deadbreak bushings or accessory devices.
Estimated time: 1h
Tools needed:
Wrench, Wire brush, Crimp tool, Fully insulated hot stick
Supplies needed:
Elbow Connector Housing, Compression Lug, Probe, Probe Contact, Lubricant, Hold-down Bail, UD cable, No. 14 AWG Copper Wire, Grounding connector
- Ensure De-energized State and Personnel Competence
DANGER: All apparatus must be de-energized during installation or removal of part(s). Do not touch or move energized products in the work area. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Failure to follow these instructions will result in damage to the product and serious or fatal injury.
- Perform Pre-Installation Checks
Verify all package contents are complete and undamaged. Confirm the elbow housing cable entrance size and compression lug size are appropriate for the cable. Thread the probe into the compression lug by hand to check for resistance; if resistance is encountered, inspect for damage and replace components as needed. Ensure all required tools are at hand and maintain cleanliness throughout the procedure.
- Train the Cable
Train the UD cable as shown in the diagram to ease operation, ensuring a minimum of 20 inches (508.0mm) beyond the end of the cable pad mount transformer. Cut any excess cable squarely at the center line of the bushing.
- Prepare Concentric Neutral Wires
Unwrap and bind the concentric neutral wires 8-1/2 inches (216.0mm) back from the end of the cable.
- Remove Shield and Insulation
Remove the shield and insulation from the cable end, cutting squarely. Take extreme care not to nick the conductor or insulation. Bevel the insulation end a maximum of 1/8 inch (3.2mm).
- Install Compression Lug
Wire brush the bare aluminum conductors immediately. Install the compression lug, rotating it to spread the inhibitor. Position the compression lug so the contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe any excessive inhibitor from the outside of the lug and cable.
- Remove Semi-Con Shield and Clean Insulation
Remove the semi-con shield as shown in the cable cut back template. Thoroughly clean the insulation to remove all traces of conductive residue, ensuring a straight, smooth, and squared surface without nicks.
- Lubricate Cable and Elbow Housing
Clean and lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant ONLY. DO NOT SUBSTITUTE other lubricants, as they may be harmful to this product or its mating product(s). Keep the insulation free of dirt and grime.
- Slide Elbow Connector onto Cable
Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off all excess silicone lubricant.
- Align and Thread Probe
Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, taking care not to cross-thread. Tighten with the supplied wrench until the wrench bends, indicating proper torque.
- Assemble Hold-Down Bail
Place the hold-down bail into the hold-down bracket. Compress the bail and insert it into the brackets.
- Connect Grounding Wire to Elbow
Insert one end of a separate No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the elbow. Twist it tightly, ensuring not to damage the eye.
- Connect Neutral Wires to Ground
Twist all concentric neutral wires together and connect them to ground using an appropriate connector. Provide adequate slack in the wires for elbow operation.
- Clean and Lubricate Mating Parts for Connection
Clean the receptacle portion of the elbow connector and the mating bushing. Lubricate these surfaces with the supplied lubricant ONLY IF the transformer and elbow are known to be DE-ENERGIZED. WARNING: Do not lubricate if energized.
- Connect Elbow to Bushing
Use a fully insulated hot stick to place the elbow onto the bushing. DO NOT OPERATE BY HAND. DO NOT SEPARATE IF ENERGIZED.
- Secure Elbow with Hold-Down Bail
Pull the hold-down bail up over the crown or top of the elbow so that the eyebolt on the bail is directly over the operating eye. Tighten down on the elbow locator by turning the eyebolt clockwise. Adjust the nut on the eyebolt to allow it to seat securely in the locator, acting as a stop to prevent excessive force on the elbow. Once set, the nut will not require readjustment for future removal/replacement.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.