ABB Installation Products 252LR-A5240 15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter…
UPC: 075114345798
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Rated for 15/25kV systems at 200 Amps continuous current
- Accommodates cable insulation diameters from 0.575 to 0.740 inches (14.61-18.80mm)
- Supports conductor sizes: 240 to 1/0 AWG stranded/compressed and 2/0 AWG solid/compact
- Bi-metal lug for compatibility with aluminum and copper conductors
- Includes non-corrosive capacitive test point for safe voltage testing without de-energizing the circuit
Specifications
Amperage Rating | 200 A |
Application | 15/25kV, 200 Amp Deadbreak Connector |
Color | Blue |
Color | Black |
Conductor Range | 1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG |
Connection | Compression |
Connection Type | Deadbreak Elbow Connector |
Connection Type | Deadbreak Elbow Connector with Test Point |
Current Rating | 200 A |
Environmental Conditions | Fully Submersible |
Insulation | True |
Length | 7.531 in |
Length | 191.2874 mm |
Material | Bi-Metal Lug, Poly (assumed from connector housing) |
Material | Housing - EPDM-Rubber |
Material | Bi-Metal Lug |
Series | 252 Series |
Series | 252LR |
Size | 5.454 x 7.531 inches, 2.097 inch diameter |
Special Features | Fully Shielded, fully Submersible Molded Rubber Housing. Provision for Hot Stick Operation. Non-Corrosive, Capacitive Test Point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Elbow Connector with Test Point |
Voltage Rating | 15/25 kV |
Voltage Rating | 15 to 25 kV |
Width | 5.454 in |
Width | 138.5316 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.6900 L |
Package Weight (Metric) | 0.7670 kg |

252LR-B5240
25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, Cable Insulation Diameter - .635-.905 inch. Bi-Metal Lug, Conductor Size 240 - 1/0 Stranded/Compressed or 2/0 Compact/Solid. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.
252LR-B5250
15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635-0.905 inches (16.13-22.99mm), Bi-Metal Lug, Conductor Size 250 - 2/0 Stranded/Compressed, 3/0 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter.
252LR-B5220-S
15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635-0.905 inches (16.13-22.99mm), Bi-Metal Lug, Conductor Size 220 - #2 Stranded/Compressed, #1 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter. Cold-Shrinkable Jacket Seal.
252LR-B5260
15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635-0.905 inches (16.13-22.99mm), Bi-Metal Lug, Conductor Size 260 - 3/0 Stranded/Compressed, 4/0 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter.
252LR-B5270-S
15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635-0.905 inches (16.13-22.99mm), Bi-Metal Lug, Conductor Size 270 - 4/0 Stranded/Compressed, 250kcmil Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter. Cold-Shrinkable Jacket Seal.
252LR-C5230
15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.805-1.060 inches (20.45-26.92mm), Bi-Metal Lug, Conductor Size 230 - #1 Stranded/Compressed, 1/0 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter.
252LR-B5230
15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635-0.905 inches (16.13-22.99mm), Bi-Metal Lug, Conductor Size 230 - #1 Stranded/Compressed, 1/0 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter.
252LR-B5270
15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635-0.905 inches (16.13-22.99mm), Bi-Metal Lug, Conductor Size 270 - 4/0 Stranded/Compressed, 250kcmil Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter.Frequently Asked Questions
When is a cable adapter required for this connector?
A cable adapter (160CA-XX) is required for cables that have an outer diameter less than 0.565 in.
What safety measure is highly recommended during installation?
For safety purposes, a sealing and grounding kit with the deadbreak elbow is highly recommended.
What sealing kit is used for Jacketed Concentric Neutral Cables?
For Jacketed Concentric Neutral Cables, use sealing kit 200ECS or add suffix "-S" to the part number for cables with a nominal O.D. between 0.80 in. and 1.50 in.
What sealing kit is used for Copper Tape Shield Cables?
For Copper Tape Shield Cables, use sealing kit 200ECS or add suffix "-S" to the part number for cables with a nominal O.D. between 0.80 in. and 1.50 in.
What shield adapter is used for Unishield Cables?
For Unishield Cables, the shield adapter part number is 10TL-W, where "W" is determined by the cable's insulation diameter, or add suffix "-TL" to the part number.
Can this connector be operated with a hot stick?
Yes, the 252LR Elbow Connector includes provisions for de-energized operation using standard hotstick tools.
What are the voltage and current ratings of this connector?
The 252LR Elbow Connector is rated for 15/25kV voltage class and has a continuous current rating of 200 Amps.
Which industry standards does the 252LR connector meet?
The 252LR Elbow Connector meets ANSI/IEEE Standard 386, Latest Revision.
What is the maximum operating voltage for the 15kV class?
For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV and the maximum phase-to-phase is 14.4kV.
What is the maximum operating voltage for the 25kV class?
For the 25kV voltage class, the maximum phase-to-ground operating voltage is 15.2kV and the maximum phase-to-phase is 26.3kV.
How to Install the 252LR Deadbreak Elbow Connector
This guide provides step-by-step instructions for installing the 252LR Deadbreak Elbow Connector, designed to terminate UD cable and connect to 25kV class deadbreak bushings or accessory devices. It covers cable preparation, assembly, and wiring.
Estimated time: 1h
Tools needed:
Wire brush, Crimp tool (refer to crimp chart for specific type), Fully insulated hot stick
Supplies needed:
252LR Deadbreak Elbow Connector kit (includes Housing, Compression Lug, Probe, Probe Contact, Wrench, Lubricant, Hold-down Bail), UD cable (with concentric neutral and semi-con shielding), No. 14 AWG (2.5mm) copper wire, Appropriate connector for grounding neutral wires
- Perform Pre-Installation Checks and Safety Measures
DANGER: Ensure all apparatus is de-energized before starting installation. This product must be installed by competent personnel trained in high voltage electrical equipment safety. Inspect all parts for damage, rating, and compatibility with mating parts. Verify the elbow housing cable entrance size and compression lug size match the cable. Check probe threads by hand-threading into the compression lug; replace damaged components if resistance is encountered. Have all required tools at hand and maintain cleanliness. If the test point cap is not installed, lubricate the cap and test point, then install the cap.
- Train the Cable
Train the UD cable as shown in the documentation (20 inches minimum beyond the end of the cable pad mount transformer) to ease operation. Cut excess cable squarely at the centerline of the bushing.
- Prepare Cable Neutral and Insulation
Unwrap and bind concentric neutral wires 8-1/2 inches (216.0mm) back from the cable end. Remove the shield and insulation from the cable end, cutting squarely without nicking the conductor. Remove the semi-con shield as shown in the template. Bevel the insulation end 1/8 inch (3.2mm) maximum. Thoroughly clean the insulation to remove all traces of conductive residue.
- Install and Crimp the Compression Lug
Wire brush bare aluminum conductors and immediately install the compression lug, rotating to spread inhibitor. Position the lug so the contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart packaged with the lug, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe excessive inhibitor from the outside of the lug and cable.
- Assemble the Elbow Connector Housing
Clean and lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant. DO NOT SUBSTITUTE other lubricants. Slide the elbow connector onto the cable using a back and forth twisting motion. Wipe off all excess silicone lubricant. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, ensuring not to cross-thread. Tighten the probe with the supplied wrench until the wrench bends.
- Assemble the Hold-Down Bail
Place the hold-down bail into the hold-down bracket. Compress the bail and insert it into the brackets.
- Connect Concentric Neutral Wires to Ground
Using a separate No. 14 AWG (2.5mm) copper wire, insert one end through the grounding eye on the elbow. Twist it tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Provide adequate slack in the wires for elbow operation.
- Connect Elbow to Mating Bushing Plug
Clean the receptacle portion of the elbow connector and the mating bushing. Lubricate both with the supplied lubricant ONLY if the transformer and elbow are known to be de-energized. Use a fully insulated hot stick to place the elbow onto the bushing. DANGER: Do not operate by hand. Do not separate if energized.
- Secure the Elbow with the Hold-Down Bail
Pull the hold-down bail up over the crown or top of the elbow so that the eyebolt on the bail is directly over the operating eye. Tighten down on the elbow locator by turning the eyebolt in a clockwise direction. Adjust the nut on the eyebolt until it allows the eyebolt to seat securely in the locator. The nut should act as a stop to prevent the eyebolt from applying excessive force on the elbow.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.