ABB - Installation Products 167RLR-G-5230 - 15kV 200 Amp, Loadbreak Replacement Elbow Connector, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

ABB Installation Products 167RLR-G-5230 15kV 200 Amp, Loadbreak Replacement Elbow Connector, Repair Elbow has extended length…

UPC: 783786646166


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This ABB Installation Products 167RLR-G-5230 is a 15kV, 200 Amp Loadbreak Replacement Elbow Connector designed for reliable power system connections. Engineered as a repair elbow, it features an extended length contact and housing, providing a significant net gain of 8-7/8 inches. This extended reach is crucial for applications requiring additional clearance or flexibility during installation and maintenance. The connector utilizes a bi-metal contact for robust electrical conductivity and durability. It is specified for cable insulation diameters ranging from 0.760 inches to 0.950 inches. For conductor sizing, it accommodates compressed stranded conductor sizes from #1 AWG up to 1/0 AWG (42.41 mm²). This makes it suitable for a range of medium voltage distribution applications. Key Specifications: * **Voltage Rating:** 15kV * **Current Rating:** 200 Amp * **Contact Type:** Bi-Metal * **Cable Insulation Diameter:** 0.760" - 0.950" * **Conductor Size:** #1 AWG to 1/0 AWG (42.41 mm²) * **Manufacturer:** ABB - Installation Products * **SKU:** 167RLR-G-5230 This loadbreak elbow connector is a direct replacement component, ensuring compatibility and efficient repair of existing electrical infrastructure. Its design prioritizes secure connections and operational integrity in medium voltage systems.
  • 15kV, 200 Amp Loadbreak Replacement Elbow Connector
  • Extended length contact and elbow housing (+8-7/8 inches)
  • Bi-metal contact for enhanced conductivity
  • Suitable for cable insulation diameters 0.760" to 0.950"
  • Accommodates conductor sizes #1 AWG to 1/0 AWG (42.41 mm²)

Specifications

Amperage Rating
200 A
Application
Designed for connecting to and operating 15kV Class, 95kV BIL apparatus
Color
Black
Conductor Range
#1 STR/COMPR AWG , 1/0 SOL/COMPT AWG
Connection Type
Compression Lug
Current Rating
200 A
Environmental Conditions
Fully Submersible
Insulation
True
Material
Bi-Metal
Material
Housing - EPDM-Rubber
Size
Cable Insulation Diameter 0.760 inch to 0.950 inch
Size
0.760 inch to 0.950 inch
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured insulation, insert and jacket. Provision for hot stick operation, Provision for ground wire connection. Wide cable range with minimum number of sizes. Extended length housing and compression lug plus 10-1/2 inch (266.7mm)
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Replacement Elbow Connector
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
4.2800 L
Package Weight (Metric)
1.9410 kg
200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.

168RLR-G-5230

200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.
POWER TERMINALS TYPE 3 RENTAL

45030034

POWER TERMINALS TYPE 3 RENTAL
25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

274RLR-H-5230

25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

376LR-K-5240

35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
25kV 200 Amp, Loadbreak Replacement Elbow Connector, Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

273RLR-H-5240

25kV 200 Amp, Loadbreak Replacement Elbow Connector, Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

376LR-L-5270

35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

376LR-L-5240

200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
600 Amp, 35KV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

755LR-J0250

600 Amp, 35KV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

Frequently Asked Questions

What is the current rating of these connectors?

These ABB Elastimold loadbreak elbow connectors are rated for 200 amps.

What standards do these elbow connectors comply with?

These connectors are IEEE 386 compliant, ANSI certified, and Rural Utilities Service (RUS) accepted.

Where are Elastimold 200 A elbows manufactured?

Elastimold 200 A repair and replacement elbows are designed, molded, and tested in Albuquerque, New Mexico, USA.

What is the catalog number for the test point cap?

The catalog number for the test point cap is 156-7.

What type of construction do these elbows feature for safety?

They feature dead-front construction, which insulates, shields, and eliminates exposure to live components.

What is the cable insulation diameter range for 167RLR-G?

For the 167RLR-G replacement elbow, the cable insulation diameter range is 0.760 in to 0.950 in.

What material are these elbow connectors made from?

The connectors are constructed from specially formulated, non-rigid ethylene propylene diene monomer (EPDM) rubber.

What is the extended length of the repair elbow?

The repair elbow features an extended length of 3 1/4 inches compared to a standard elbow.

What is the extended length of the replacement elbow?

The replacement elbow provides a net gain of 8 7/8 inches in length due to its extended housing and compression lug.

What voltage classes are available for these elbows?

The ABB Elastimold loadbreak repair and replacement elbows are available for 15 kV and 25 kV voltage classes.

How to Install Elastimold 167RLR/168RLR Loadbreak Replacement Elbow Connectors

This guide provides step-by-step instructions for the safe installation and initial setup of Elastimold 167RLR and 168RLR Loadbreak Replacement Elbow Connectors, including cable preparation, lug installation, elbow assembly, and neutral connection.

Estimated time: 1h 30m

Tools needed:

Cable cutting tool, Insulation stripping tool, Wire brush, Probe wrench, Hotstick, Suitable sensing device (for 168RLR voltage test)

Supplies needed:

Replacement Elbow Connector Housing, Compression Lug, Probe, Lubricant (Do Not Substitute), Hose Clamp, Copper wire (No. 14 AWG / 2.5mm or equivalent), Appropriate connector (for neutral wires)

  1. Perform Pre-Installation Checks and De-energize Apparatus

    DANGER: All apparatus must be de-energized during installation or removal of parts. Check the contents of the package to ensure they are complete and undamaged. Verify all components fit properly with the cable and/or mating products. Check probe threads by threading the probe into the compression lug; if resistance is encountered, check for damage and replace. Read all instructions before starting and have all required tools at hand, maintaining cleanliness throughout the procedure.

  2. Remove Existing Livefront Termination

    Remove the rubber cap from the existing terminator. Cut off the connector at the top of the terminator. Disconnect the ground lead from the base of the terminator. Finally, remove the terminator housing from the cable.

  3. Prepare the Cable

    Train the cable to be straight and in-line with the bushing centerline. Cut the cable to measure 10-1/2 inches from the bushing centerline. Check the insulation shield distance: if it measures less than 6-1/2 inches, proceed. If it is greater than 6-1/2 inches, consult your nearest ELASTIMOLD representative. Remove 1-3/8 inches of cable insulation from the end of the cable, cutting squarely. DO NOT NICK THE CONDUCTOR.

  4. Install the Compression Lug

    Wire brush the bare aluminum conductor and immediately install the compression lug. Rotate the lug to spread the inhibitor. Position the compression lug so the contact threaded hole aligns with the bushing bore. Refer to the crimp chart packaged with the compression lug for recommended crimp information. Start crimping at the crimp line mark, rotating 180 degrees for each successive crimp. Carefully wipe any excessive inhibitor from the outside of the lug and cable.

  5. Assemble the Elbow Connector

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant. DO NOT SUBSTITUTE, as other lubricants may be harmful. Keep the insulation clean of dirt and grime, and do not use excess grease or introduce any grease into the gap between the lug and the insulation. Slide the elbow connector onto the cable with a back and forth twisting motion. Wipe off all excess grease. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, taking care not to cross-thread. The probe must turn freely for approximately four turns before becoming snug. Tighten the probe with the wrench until the wrench bends.

  6. Connect the Concentric Neutral

    Using a separate copper wire (No. 14 AWG / 2.5mm) or equivalent, insert one end through the grounding eye on the elbow and twist it tight, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Provide adequate slack in the wires for elbow operation. Add the supplied hose clamp as shown in the documentation and tighten it snugly, but do not overtighten.

  7. Connect the Elbow to the Bushing Plug

    Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. LUBRICATE ONLY IF THE TRANSFORMER AND ELBOW ARE KNOWN TO BE DE-ENERGIZED. Securely fasten a hotstick to the loadbreak connector pulling eye. Place the elbow connector receptacle area over the bushing plug, inserting the elbow male contact (arc follower portion) into the bushing until the first slight resistance is felt (contacts are approximately 2 inches apart). DO NOT HOLD IN THIS POSITION, but immediately push the elbow home with a fast, firm, straight motion to engage the internal lock on the elbow and bushing interface. Apply sufficient force to engage the internal lock.

  8. Perform Voltage Test (168RLR ONLY)

    If installing a 168RLR model, you can perform a voltage test. Remove the test point cap with a hotstick, peeling it off at an angle rather than pulling directly in line with the assembly. WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Follow the manufacturer’s directions for the meter used. Test with a suitable sensing device made for use with separable connectors manufactured with capacitive test points to determine if the cable is energized. Contamination, moisture, dirt, or using the wrong equipment can provide a false 'no voltage' indication. To prevent serious or fatal injury, treat the elbow as energized until the 'no voltage' test point indication is confirmed by other means. After voltage detection, clean and lubricate the inside surface of the cap with silicone grease and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.