ABB Installation Products 168RLR-G-5250 200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation…
UPC: 783786639779
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 200 Amp, 15kV Class loadbreak replacement elbow connector
- Extended length housing and compression lug (+10.5 inches / 266.7 mm)
- Bi-metal compression lug compatible with 2/0 AWG (compressed) to 3/0 AWG (solid) conductors
- Supports cable insulation diameters from 0.760 to 0.950 inches (19.30 to 24.13 mm)
- Non-corrosive capacitive test point for diagnostics and monitoring
Specifications
Amperage Rating | 200 A |
Application | Designed for connecting to and operating 15kV Class, 95kV BIL apparatus |
Color | Black |
Conductor Range | 2/0 STR/COMPR AWG , 3/0 SOL/COMPT AWG |
Connection Type | Compression Lug |
Connection Type | Bolted, Loadbreak, Test Point |
Current Rating | 200 A |
Environmental Conditions | Fully Submersible |
Insulation | True |
Ip Rating | Fully Submersible |
Material | Housing - EPDM-Rubber |
Material | Bi-Metal, Poly |
Material | Molded Rubber, Bi-Metal |
Mounting Type | Elbow Connector |
Poles | 1P+G |
Series | 168RLR-G |
Series | 168RLR |
Size | 0.760-0.950 inch (insulation diameter), 2/0 AWG (compressed) to 3/0 AWG (solid) |
Size | Cable Insulation Diameter 0.760 inch to 0.950 inch |
Special Features | Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured insulation, insert and jacket. Provision for hot stick operation, Provision for ground wire connection. Wide cable range with minimum number of sizes. Extended Length Housing and Compression Lug - plus 10-1/2 inch (266.7mm). Non-Corrosive Capacitive Test Point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Replacement Elbow Connector with Test Point |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 3.1000 L |
Package Weight (Metric) | 1.4060 kg |

K151SR-B0250-S
15/25kV, 200 Amp, Deadbreak Straight Receptacle without Test Point, Cable Insulation Diameter 0.635 to 0.905 inches, Aluminum, Conductor Size 250 - 2/0 Stranded/Compressed or 3/0 Solid/Compact. S - Cold-Shrinkable Jacket Seal
167LRT-G5230
200 Amp, 15kV, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. Includes 02800X Bi-Metal Contact.
376LR-J-5260
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.
376LR-H-5240
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
167RLR-G-5230
15kV 200 Amp, Loadbreak Replacement Elbow Connector, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
274RLR-H-5230
25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
376LR-K-5240
35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
273RLR-H-5240
25kV 200 Amp, Loadbreak Replacement Elbow Connector, Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.Frequently Asked Questions
What is the current rating of the elbow connectors?
The elbow connectors are rated for 200 A loadbreak applications.
What voltage classes do these connectors support?
The ABB Elastimold loadbreak repair and replacement elbows are available for 15 kV and 25 kV voltage classes.
How much length does the repair elbow add?
The repair elbow features an extended housing and compression lug length that is 3 1/4 inches longer than the standard elbow.
How much length does the replacement elbow add?
The replacement elbow extends its housing and compression lug length to 8 7/8 inches over the standard elbow.
What material are the elbows constructed from?
The elbows are constructed from specially formulated, non-rigid ethylene propylene diene monomer (EPDM) rubber.
Are these elbow connectors certified?
Yes, these connectors are IEEE 386 compliant, ANSI certified, and Rural Utilities Service (RUS) accepted.
Where are Elastimold elbows manufactured?
Elastimold 200 A repair and replacement elbows are designed, molded, and tested in Albuquerque, NM, USA.
What is the test point cap catalog number?
The test point cap catalog number for elbows with a test point is 156-7.
What safety features do these connectors offer?
They feature dead-front construction, EPDM rubber for controlled gas release, an optional capacitive test point, a non-stick interface, and a stainless steel pulling eye.
Does the 168RLR elbow include a test point?
Yes, the 168RLR is a replacement elbow that includes an optional built-in capacitive test point. This allows for testing the circuit for the presence of voltage.
How to Install 168RLR Loadbreak Replacement Elbow Connectors
This guide provides step-by-step instructions for installing the 168RLR Loadbreak Replacement Elbow Connector, converting a livefront termination to deadfront for UD cable. It covers cable preparation, lug installation, elbow assembly, and grounding.
Estimated time: 45m
Tools needed:
Probe Wrench, Wire brush, Wire strippers, Cable cutting tool, Crimping tool, Hotstick
Supplies needed:
Replacement Elbow Connector Housing, Compression Lug, Probe, Lubricant (supplied with kit), Hose Clamp (supplied with kit), Copper wire (No. 14 AWG / 2.5mm) for grounding, Grounding connector
- De-energize and Remove Existing Livefront Terminator
DANGER: All apparatus must be de-energized during installation or removal of part(s). Failure to follow these instructions will result in damage to the product and serious or fatal injury. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Begin by removing the rubber cap from the terminator. Next, cut off the connector at the top of the terminator. Disconnect the ground lead from the base of the terminator, then remove the entire terminator housing from the cable.
- Prepare the Cable
Train the cables to be straight and in-line with the bushing centerline. Measure and cut the cable to 10-1/2 inches from the bushing centerline. Ensure the insulation shield measures at least 6-1/2 inches from the end of the cut cable; if it's greater, consult an ELASTIMOLD representative. Carefully remove 1-3/8 inches of cable insulation from the end, cutting squarely and ensuring not to nick the conductor.
- Install the Compression Lug
Wire brush the bare aluminum conductor thoroughly and immediately install the compression lug. Rotate the lug to spread the inhibitor. Position the compression lug so its contact threaded hole aligns with the bushing bore. Refer to the crimp chart packaged with the compression lug for specific crimp information. Start crimping at the crimp line mark, rotating 180 degrees for each successive crimp. Carefully wipe any excessive inhibitor from the outside of the lug and cable.
- Assemble the Elbow Housing
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; do not substitute. Slide the elbow connector onto the cable using a back and forth twisting motion, then wipe off all excess grease. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, ensuring not to cross-thread. The probe should turn freely for approximately four turns before becoming snug. Tighten the probe with a wrench until the wrench bends.
- Connect the Concentric Neutral
Insert one end of a separate copper wire (No. 14 AWG / 2.5mm or equivalent) through the grounding eye on the elbow and twist it tight, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, providing adequate slack in the wires for elbow operation. Finally, add the supplied hose clamp as shown in the documentation and tighten it snugly, but do not overtighten.
- Connect Elbow to Bushing Plug
Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. IMPORTANT: Only lubricate if the transformer and elbow are known to be de-energized. Operate the connection using a full insulated hotstick type live-line tool as per operating instructions; do not operate by hand.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.