ABB - Installation Products 167LRT-F5220 - 15kV 200 Amp, Loadbreak Bolted Elbow with Tap. Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

ABB Installation Products 167LRT-F5220 15kV 200 Amp, Loadbreak Bolted Elbow with Tap. Cable Insulation Diameter 0.640 inch to…

UPC: 783786632732


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call (262) 252-1600 or email [email protected] for pricing and availability.

Overview

The ABB 167LRT-F5220 is a 15kV, 200 Amp Loadbreak Bolted Elbow Tap designed for underground residential distribution (URD) networks, pad-mounted transformers, and switchgear applications. This deadbreak elbow connector features a fully-shielded, fully submersible molded rubber housing that meets ANSI/IEEE Standard 386 requirements, ensuring reliable performance in harsh underground environments. Key specifications include a maximum phase-to-ground operating voltage of 8.3 kV, phase-to-phase voltage of 14.4 kV, and a basic impulse level (BIL) of 95 kV. The connector supports continuous and loadbreak currents up to 200 Amps, with a momentary and fault close rating of 10 kA symmetrical for 10 cycles. It accommodates cable insulation diameters from 0.640 inch to 0.820 inch and conductor sizes from #2 AWG compressed stranded to solid #1 AWG (33.62 mm²), using a bi-metal compression lug for secure, low-resistance connections with copper or aluminum conductors. The 167LRT-F5220 includes a loadbreak tap point for safe phasing, grounding, testing, or arrester protection under load conditions. Installation is simplified with the supplied tool kit, which contains a compression lug (02800X), stud extender (167-112), lubricant (82-08), installation tool (200-15), wrench (271-94), and installation instructions (IS-0354-167LRT). The connector mates with ANSI Std. 386, Fig. 3 bushing wells and conforms to ANSI Std. 386, Fig. 5 for compatibility with standard 15kV-class equipment. This elbow connector is ideal for primary and secondary distribution circuits requiring 15kV class equipment, providing a fully-rated loadbreak interface for utility operations.
  • 15kV, 200 Amp deadbreak elbow connector with loadbreak tap point
  • Fully-shielded, fully submersible molded rubber housing (ANSI/IEEE Std. 386 compliant)
  • Supports cable insulation diameters from 0.640" to 0.820" and conductor sizes #2/AWG to #1/AWG (33.62 mm²)
  • Bi-metal compression lug for secure, low-resistance connections with copper or aluminum conductors
  • Includes installation tool kit with compression lug, stud extender, lubricant, and wrench

Specifications

Amperage Rating
200 A
Application
15kV, 200 Amps
Color
Black
Conductor Range
#2 STR/COMPR AWG , #1 SOL/COMPT AWG
Connection Type
Bolted, Loadbreak
Current Rating
200 A
Environmental Conditions
Fully Submersible
Insulation
True
Material
Housing - EPDM-Rubber
Material
Bi-Metal, Poly
Series
167LRT
Size
0.640-0.820 inch (insulation diameter), #2/AWG compressed stranded to solid #1/AWG
Size
Cable Insulation Diameter 0.640 inch to 0.820 inch
Special Features
Includes 02800X Bi-Metal Contact
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Bolted Elbow with Tap
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
3.0000 L
Package Weight (Metric)
1.3610 kg
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, #2 Stranded Wire Size. Bi-Metal Compression Lug

162LR-B-5220

15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, #2 Stranded Wire Size. Bi-Metal Compression Lug
6MM2 BLACK CABLE FOR DISTRIBUTION BLOCK ROW TYPE LENGTH 320MM

54211116

6MM2 BLACK CABLE FOR DISTRIBUTION BLOCK ROW TYPE LENGTH 320MM
25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

274RLR-H-5240

25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
15kV 200 Amp, Loadbreak Replacement Elbow Connector, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

167RLR-G-5240

15kV 200 Amp, Loadbreak Replacement Elbow Connector, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.

168RLR-G-5250

200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.
200 Amp, 15kV, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. Includes 02800X Bi-Metal Contact.

167LRT-G5230

200 Amp, 15kV, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. Includes 02800X Bi-Metal Contact.
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.

376LR-J-5260

200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

376LR-H-5240

200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

Frequently Asked Questions

What is the 167LRT product?

The 167LRT is an Elastimold Bolted Elbow with Tap, functioning as a loadbreak elbow connector with a loadbreak tap.

What bushing wells are compatible with the 167LRT?

The 167LRT mates with bushing wells that conform to ANSI Std. 386, Fig. 3.

What is the one-minute AC withstand rating?

The one-minute AC withstand rating for the 167LRT is 34kV AC.

What is the impulse withstand rating of the 167LRT?

The 167LRT has a 95kV BIL impulse withstand rating, based on a 1.2 x 50 microsecond wave.

Can I order an all copper compression lug?

Yes, for an all copper compression lug, substitute the prefix "2" instead of "5" in the compression lug code.

What installation tools are included in the 167LRT kit?

The kit includes an installation tool (200-15) and a wrench (271-94).

What safety precaution is needed for the loadbreak tap point?

The loadbreak-rated tap point must be covered with an insulated cap when it is not in use.

What is the continuous and loadbreak current rating?

The 167LRT has a continuous and loadbreak current rating of 200 Amps.

What is the maximum phase-to-ground operating voltage?

The maximum phase-to-ground operating voltage for the 167LRT is 8.3 kV.

What is the voltage class of the 167LRT?

The 167LRT is rated for a 15kV Voltage Class.

How to Install the Elastimold 167LRT Loadbreak Bushing Tap

This guide provides step-by-step instructions for the safe and proper installation of the Elastimold 167LRT Loadbreak Bushing Tap. Ensure all apparatus is de-energized during installation and that only competent personnel trained in high voltage safety practices perform the installation.

Estimated time: 1h 30m

Tools needed:

Wrenches, Installation Tool, Wire brush, Crimp tool, Wire strippers

Supplies needed:

Bushing Tap Housing, Compression Lug, Socket Contact, Lubricant (Do Not Substitute), Well Contact, UD cable, No. 14 AWG (2.5mm) copper wire, Appropriate ground connector, Protective shipping cap, HV insulated cap or connector, Insulated Cap or Elbow

  1. Remove Shipping Covers and Install HV Caps

    If the product is supplied with protective shipping cover(s), remove them. Immediately replace these shipping cover(s) with the appropriate HV insulated cap(s) or connector(s) before submerging or energizing the circuit. The shipping cap is not insulated or watertight and is for protection during handling only.

  2. Train the Cable

    Train the UD cable as shown in the diagram to ease operation. Cut excess cable squarely at the center line of the bushing, ensuring a minimum of 20 inches beyond the end of the cable.

  3. Prepare the Cable End

    Unwrap and bind concentric neutral wires 8-1/2 inches back from the end of the cable. Remove the shield and insulation from the cable end, cutting squarely and taking care not to nick the conductor. Wire brush bare aluminum conductors and immediately install the compression lug, rotating to spread inhibitor. Position the compression lug so its threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe excessive inhibitor from the outside of the lug and cable. Remove the semi-con shield as shown in the template and bevel the insulation end a maximum of 1/8 inch. Thoroughly clean the insulation to remove all traces of conductive residue.

  4. Assemble the Well Contact

    Thread the well contact onto the bushing well stud by hand, ensuring not to cross-thread. Tighten the well contact with the supplied wrench until the wrench bends, indicating proper torque.

  5. Assemble the Bushing Tap Housing

    Remove the protective cap from the bushing tap and retrieve the socket contact stored inside the bushing tap housing. Lubricate the cable insulation and the inside of the bushing housing with the supplied lubricant only; do not substitute. Keep insulation clean and avoid introducing grease into the gap between the lug and insulation. Slide the bushing tap onto the cable using a back and forth twisting motion, then wipe off all excess grease. Align the bushing with the compression lug hole and assemble the socket contact into the bushing tap, ensuring the socket contact stud passes through the lug hole.

  6. Mount the Bushing Tap

    Inspect the apparatus bushing well to ensure it is dry and free from contaminants. Lubricate the bushing well interface area of the bushing tap with the supplied or Elastimold approved lubricant. Place the lubricated bushing tap into the apparatus bushing well. Insert the installation tool into the bore of the bushing tap until fully seated. Insert the wrench through the wrench hole of the tool and turn clockwise until the wrench bends, signifying proper assembly torque. Remove the wrench and installation tool from the bushing tap, cleaning the tool before insertion.

  7. Connect the Concentric Neutral

    Insert one end of a No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the bushing tap. Twist it tight, taking care not to damage the eye. Twist the neutral wires together and connect them to ground using an appropriate connector.

  8. Prepare for Mating or Cap

    Thoroughly wipe the bushing tap interface clean of any contaminants and apply a light, uniform coat of supplied lubricant, working it thoroughly into the surface. CAUTION: Excess lubricant may prevent a loadbreak elbow from being fully seated. Install mating products (e.g., loadbreak elbow, insulated cap, or grounding elbow connector) following their specific instructions. If not immediately mating, replace the shipping cap. Do not energize or submerge the apparatus with the shipping cap, as it is only a protective cover and not insulated or watertight.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.