Authorized ABB Distributor (Installation Products)
ABB - Installation Products 167LRT-G-5250 - 15kV 200 Amp, Loadbreak Bolted Elbow with Tap. Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

ABB Installation Products 167LRT-G-5250 15kV 200 Amp, Loadbreak Bolted Elbow with Tap. Cable Insulation Diameter 0.760 inch to…

UPC: 783786658787


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 167LRT-G-5250 Loadbreak Bolted Elbow with Tap is a 15kV, 200 Amp rated connector designed for medium-voltage cable systems. This bolted elbow tap accommodates cable insulation diameters from 0.760 inch to 0.950 inch, making it suitable for 2/0 and 3/0 AWG compressed stranded conductors or 67.43 mm² solid conductors. The bi-metal compression lug ensures reliable electrical contact and mechanical strength, reducing installation time and improving system integrity. Engineered for underground distribution networks, this elbow tap is ideal for utility, industrial, and commercial applications requiring safe loadbreak operations. The bolted design allows for easy installation and removal without disrupting service, while the loadbreak feature enables hot-line maintenance when paired with compatible elbows. The compact form factor and robust construction support long-term reliability in harsh environments. Compatible with 15kV class systems, this product meets stringent electrical and mechanical standards for medium-voltage cable accessories. The ABB 167LRT-G-5250 is a cost-effective solution for tapping into existing circuits, enabling efficient power distribution and system expansion.
  • 15kV rated, 200 Amp continuous current
  • Loadbreak design for hot-line maintenance
  • Bi-metal compression lug for 2/0-3/0 AWG or 67.43 mm² solid conductors
  • Cable insulation diameter range: 0.760" to 0.950"
  • Bolted elbow tap for underground distribution systems

Specifications

Amperage Rating
200 A
Application
15kV, 200 Amps
Color
Black
Conductor Range
2/0 STR/COMPR AWG , 3/0 SOL/COMPT AWG
Conductor Size
AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43
Connection Type
Loadbreak Bolted Elbow with Tap
Current Rating
200 A
Environmental Conditions
Fully Submersible
Insulation
True
Material
Housing - EPDM-Rubber
Material
Bi-Metal Compression Lug
Size
Cable Insulation Diameter 0.760 inch to 0.950 inch
Special Features
Includes 02800X Bi-Metal Contact
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Bolted Elbow with Tap
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
3.0000 L
Package Weight (Metric)
1.3610 kg
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS-G3 Jacket Seal and Grounding Kit Included.

162LR-B5250-SG3

200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS-G3 Jacket Seal and Grounding Kit Included.
35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

376LR-K-5250

35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

376LR-H-5250

35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

376LR-J-5250

200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
200 Amp, 15kV, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67. Includes 02800X Bi-Metal Contact.

167LRT-F5210

200 Amp, 15kV, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67. Includes 02800X Bi-Metal Contact.
15kV 200 Amp, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

167LRT-G5240

15kV 200 Amp, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
200 Amp, 25kV, Loadbreak Replacement Elbow Connector without Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

273RLR-J-5240

200 Amp, 25kV, Loadbreak Replacement Elbow Connector without Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
15kV 200 Amp, Loadbreak Replacement Elbow Connector, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.640 inch to 0.820 inch. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

167RLR-F-5220

15kV 200 Amp, Loadbreak Replacement Elbow Connector, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.640 inch to 0.820 inch. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

Frequently Asked Questions

What conductor sizes does this support?

It supports 2/0 and 3/0 AWG compressed stranded conductors or 67.43 mm² solid conductors.

What is the cable insulation diameter range?

The connector accommodates cable insulation diameters from 0.760 inch to 0.950 inch.

What is the current rating of this elbow tap?

The device has a 200 Amp continuous current rating.

What is the maximum operating voltage?

The device is rated for 15kV maximum operating voltage.

Is this product loadbreak rated?

Yes, the 167LRT-G-5250 is designed with a loadbreak feature for safe hot-line maintenance.

What type of lug does this elbow tap use?

It uses a bi-metal compression lug for reliable electrical contact.

How to Install the 167LRT Loadbreak Bushing Tap

This guide provides step-by-step instructions for installing the 167LRT Loadbreak Bushing Tap, designed to terminate UD cable and connect to 15kV class loadbreak elbow or accessory devices.

Estimated time: 1h 30m

Tools needed:

Wrenches, Installation Tool, Crimp tool, Wire brush

Supplies needed:

Bushing Tap Housing, Compression Lug, Socket Contact, Lubricant (Do Not Substitute), Well Contact, UD cable, No. 14 AWG (2.5mm) copper wire, Appropriate ground connector, Insulated cap(s) or connector(s)

  1. Prepare for Installation and Safety

    Ensure all apparatus is de-energized before starting installation. Inspect all parts for damage, correct rating, and compatibility with mating parts. Read the entire installation instructions thoroughly and have all required tools at hand, maintaining cleanliness throughout the procedure. Remove any protective shipping covers and replace with appropriate HV insulated caps or connectors before energizing or submerging the circuit.

  2. Train and Cut Cable

    Train the UD cable as shown in the diagram to facilitate future operation. Cut the excess cable squarely at the center line of the bushing, ensuring at least 20 inches beyond the end of the cable.

  3. Prepare Cable End

    Unwrap and bind the concentric neutral wires 8-1/2 inches back from the end of the cable. Carefully remove the shield and insulation from the cable end, cutting squarely and taking care not to nick the conductor. Wire brush the bare aluminum conductors immediately and install the compression lug. Rotate the lug to spread the inhibitor and position it so the contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe any excessive inhibitor from the outside of the lug and cable. Remove the semi-con shield as shown and bevel the insulation end to a maximum of 1/8 inch. Thoroughly clean the insulation to remove all traces of conductive residue.

  4. Assemble Bushing Well Contact

    Thread the well contact onto the bushing well stud by hand, being careful not to cross-thread. Tighten the well contact with the supplied wrench until the wrench bends, signifying that the proper assembly torque has been reached.

  5. Assemble Bushing Tap Housing

    Remove the protective cap from the bushing tap and retrieve the socket contact stored inside the bushing tap housing. Lubricate the cable insulation and the inside of the bushing housing with the supplied lubricant (DO NOT SUBSTITUTE). Keep the insulation clean of dirt and grime, and do not use excess grease or introduce any grease into the gap between the lug and the insulation. Slide the bushing tap onto the cable using a back and forth twisting motion, then wipe off all excess grease. Align the bushing with the compression lug hole and assemble the socket contact into the bushing tap, ensuring the socket contact stud passes through the lug hole.

  6. Mount and Torque Bushing Tap

    Inspect the apparatus bushing well to ensure it is dry and free from all contaminants. Lubricate the bushing well interface area of the bushing tap with the supplied or ELASTIMOLD approved lubricant. Place the lubricated portion of the bushing tap into the apparatus bushing well. Insert the installation tool into the bore of the bushing tap until it is fully seated. Insert the wrench through the wrench hole of the tool and turn it in a clockwise direction until the wrench bends, signifying that the proper assembly torque has been reached. Remove the wrench and installation tool from the bushing tap.

  7. Connect Concentric Neutral

    Insert one end of a No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the bushing tap. Twist the wire tight, taking care not to damage the eye. Twist the neutral wires together and connect them to ground using an appropriate connector.

  8. Final Lubrication and Mating

    Thoroughly wipe the bushing tap interface clean of any contaminants. Apply a light, uniform coat of the supplied lubricant, working it thoroughly into the surface. CAUTION: Excess lubricant may prevent a loadbreak elbow from being fully seated in the "locked on" position. Install the mating products (e.g., loadbreak elbow, insulated cap, or grounding elbow connector) to the bushing tap following the instructions supplied with those mating products. If the bushing tap is not to be immediately mated, replace the shipping cap; however, do not energize or submerge the apparatus with the shipping cap on the bushing tap as it is only a protective cover and not insulated or watertight.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.