Authorized ABB Distributor (Installation Products)
ABB - Installation Products K151SR-B0250-S - 15/25kV, 200 Amp, Deadbreak Straight Receptacle without Test Point, Cable Insulation Diameter 0.635 to 0.905 inches, Aluminum, Conductor Size 250 - 2/0 Stranded/Compressed or 3/0 Solid/Compact. S - Cold-Shrinkable Jacket Seal

ABB Installation Products K151SR-B0250-S 15/25kV, 200 Amp, Deadbreak Straight Receptacle without Test Point, Cable Insulation…

UPC: 075114331562


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K151SR-B0250-S is a 15/25kV, 200 Amp deadbreak straight receptacle designed for medium-voltage cable terminations in underground distribution systems, switchgear, and pad-mounted transformers. This aluminum connector accommodates conductor sizes from 250 to 2/0 stranded or 3/0 solid/compact, with cable insulation diameters ranging from 0.635 to 0.905 inches. The cold-shrinkable jacket seal (S) ensures a reliable, moisture-resistant termination without heat or specialized tools, reducing installation time and labor costs. Rated for 200 Amps continuous current, the deadbreak design allows safe connection and disconnection under load, minimizing downtime during maintenance or reconfiguration. The aluminum construction provides corrosion resistance and mechanical strength, while the cold-shrinkable seal maintains dielectric integrity in harsh environments. This product is part of ABB’s Installation Products line, ensuring compatibility with industry-standard medium-voltage systems. Key specifications include: - Voltage class: 15/25kV - Continuous current rating: 200 Amps - Conductor size range: 250-2/0 stranded or 3/0 solid/compact - Cable insulation diameter range: 0.635 to 0.905 inches - Enclosure material: Aluminum - Seal type: Cold-shrinkable jacket Applications include underground distribution systems, switchgear, and pad-mounted transformers where reliable, long-term cable terminations are required. The deadbreak feature enables safe operation under load, reducing downtime during maintenance or system reconfiguration. The cold-shrinkable seal eliminates the need for heat-shrink or molded terminations, simplifying installation and reducing labor costs.
  • 15/25kV voltage class, 200 Amp continuous current rating
  • Accommodates conductor sizes 250-2/0 stranded or 3/0 solid/compact
  • Cable insulation diameter range: 0.635 to 0.905 inches
  • Cold-shrinkable jacket seal for moisture-resistant termination
  • Deadbreak design allows safe connection/disconnection under load

Specifications

Amperage Rating
200 A
Application
Designed to connect a cable to another cable or apparatus
Color
Black
Conductor Range
2/0 STR/COMPR AWG , 3/0 SOL/COMPT AWG
Environmental Conditions
Fully Shielded, Fully Submersible
Insulation
True
Length
9.54 in
Length
242.316 mm
Material
Housing - EPDM-Rubber
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for ground wire connection. Wide cable range with minimum number of sizes. No Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Straight Receptacle
Voltage Rating
15 to 25 kV
Width
2.74 in
Width
69.596 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2/0 AWG Stranded/Compressed, 3/0 AWG Solid/Compact.

168FLR3B0250

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2/0 AWG Stranded/Compressed, 3/0 AWG Solid/Compact.
25 kV, 600 Amp, Deadbreak, Elbow Kit, with Test Point, Insulated Plug, Cap, Stud, Aluminum Lug, and Cable Adapter. Cable Insulation Diameter .980-1.180. Conductor Size 1/0 Stranded/Compressed or 2/0 Compact/Solid, with Sealing Kit - Cold-Shrinkable Seal with Copper Braid and Constant Spring Force.

K656LR-J0240-SG3

25 kV, 600 Amp, Deadbreak, Elbow Kit, with Test Point, Insulated Plug, Cap, Stud, Aluminum Lug, and Cable Adapter. Cable Insulation Diameter .980-1.180. Conductor Size 1/0 Stranded/Compressed or 2/0 Compact/Solid, with Sealing Kit - Cold-Shrinkable Seal with Copper Braid and Constant Spring Force.
15/25kV, 600 Amp, Deadbreak Elbow without Test Point, with Sealing Kit. Cable Insulation Diameter Range 0.980 to 1.180 inch, Conductor Size kcmil Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185. Bi-Metal Lug.

K655LR-J5300-SG3

15/25kV, 600 Amp, Deadbreak Elbow without Test Point, with Sealing Kit. Cable Insulation Diameter Range 0.980 to 1.180 inch, Conductor Size kcmil Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185. Bi-Metal Lug.
900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compact/Solid 1250.

K675LR-N2420

900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compact/Solid 1250.
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, #1 Stranded/Compressed or 1/0 Solid/Compact Wire Size, Copper Compression Lug, Sealing Kit - Cold Shrinkable Seal with Copper Braid and Constant Force Spring.

162LR-B2230-SG3

15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, #1 Stranded/Compressed or 1/0 Solid/Compact Wire Size, Copper Compression Lug, Sealing Kit - Cold Shrinkable Seal with Copper Braid and Constant Force Spring.
15/25kV, 600 Amp, Direct Test Elbow, DeadBreak, Cable Insulation 1.090-1.310 inches, Aluminum Compression Lug, Conductor Size 4/0 Stranded/Compressed or 250 Solid/Compact. Sealing Kit - Cold Shrinkable Seal with Copper Braid and Constant Force Spring.

K655DLR-K0270-SG3

15/25kV, 600 Amp, Direct Test Elbow, DeadBreak, Cable Insulation 1.090-1.310 inches, Aluminum Compression Lug, Conductor Size 4/0 Stranded/Compressed or 250 Solid/Compact. Sealing Kit - Cold Shrinkable Seal with Copper Braid and Constant Force Spring.
15/25kV, 600 Amp, Direct Test Elbow, DeadBreak, Cable Insulation 1.180-1.465 inches, Aluminum Compression Lug, Conductor Size 1/0 Stranded/Compressed or 2/0 Solid/Compact. Sealing Kit - Cold Shrinkable Jacket Seal.

K655DLR-L0240-S

15/25kV, 600 Amp, Direct Test Elbow, DeadBreak, Cable Insulation 1.180-1.465 inches, Aluminum Compression Lug, Conductor Size 1/0 Stranded/Compressed or 2/0 Solid/Compact. Sealing Kit - Cold Shrinkable Jacket Seal.
15/25kv, 600 Amps, Deadbreak Direct Test Elbow without Test Point. With Cold-Shrinkable Jacket with Copper Braid and Constant Force Spring. Universal Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size AWG or kcmil, Compressed Stranded 350 Compacted, Solid 400.

K655DLR-J0300-SG3

15/25kv, 600 Amps, Deadbreak Direct Test Elbow without Test Point. With Cold-Shrinkable Jacket with Copper Braid and Constant Force Spring. Universal Aluminum Compression Lug. Cable Insulation Diameter 0.980 inch to 1.180 inch. Conductor Size AWG or kcmil, Compressed Stranded 350 Compacted, Solid 400.

Frequently Asked Questions

Is the K151SR receptacle fully submersible?

Yes, the K151SR features a fully shielded, fully submersible molded rubber housing.

What is the K151SR Deadbreak Straight Receptacle used for?

It is a fully shielded, fully submersible, separable insulated connector designed to connect a cable to another cable or apparatus.

What voltage systems is the K151SR suitable for?

The K151SR is suitable for use on both 15kV and 25kV systems.

What cable insulation diameters are compatible with K151SR?

The K151SR will accommodate cable insulation diameters from .575 inches through 1.220 inches.

What is the continuous current rating for the K151SR?

The K151SR has a continuous current rating of 200 Amps for both 15kV and 25kV voltage classes.

Does the K151SR have a provision for a ground wire?

Yes, the K151SR features a provision for a ground wire connection.

What standard does the K151SR meet?

The K151SR meets ANSI/IEEE Standard 386, Latest Revision.

What conductor sizes can the K151SR accommodate?

The K151SR can accommodate conductor sizes from No. 4 solid through 4/0 stranded.

What is included in the K151SR kit?

Each kit contains one straight receptacle housing, one receptacle pin connector, one tube of lubricant, installation instructions, and a crimp chart.

When can the disconnectible feature be used safely?

The disconnectible feature can be used only when the circuit is de-energized.

How to Install the Elastimold 151SR/K151SR Straight Receptacle

This guide provides step-by-step instructions for preparing the cable, installing the conductor contact, and connecting the Elastimold 151SR/K151SR straight receptacle to a mating product and system ground. Ensure all apparatus are de-energized before beginning.

Estimated time: 1h 30m

Tools needed:

Cable cutting tool, Wire strippers, Wire brush, Crimping tool, Rag, Approved solvent, Measuring tape or ruler

Supplies needed:

151SR/K151SR Straight Receptacle, Conductor Contact (male), Nylon Venting Rod, Lubricant (supplied), Crimp Chart, Inhibitor (in crimp barrel), Elastimold bail, #14 AWG or equivalent copper wire (customer supplied), Silicone grease, Elastimold insulating plug (K150DP) (if required)

  1. Perform Initial Safety Checks and Inspections

    De-energize all apparatus before beginning installation or removal of parts. Inspect all components for damage, proper rating, and compatibility with mating parts. Ensure this product is installed only by competent personnel trained in high voltage electrical equipment safety practices. Remove any protective shipping covers and replace with appropriate HV insulated caps or connectors before submerging or energizing the circuit.

  2. Prepare Cable Jacket (Concentric Neutral Cable)

    For jacketed concentric neutral cable, cut and remove the cable jacket a distance of 8 inches from the cable end. Allow sufficient concentric neutral wires for connecting to the ground point as required by the installation.

  3. Prepare Cable Jacket and Shield (Copper Tape Shield Cable)

    For copper tape shield cable, cut and remove the cable jacket a distance of 7 1/2 inches from the cable end. Remove the copper tape shield a distance of 6 1/2 inches from the end of the cable. If using an ECS or MA grounding device, follow its specific installation instructions regarding outer jacket cut back.

  4. Prepare Conductor and Crimp Terminal

    Remove 7/8 inch to 1 inch (or 1 3/4 inches to 1 7/8 inches for #1 stranded/compressed and #1/0 compressed/solid aluminum cable) of cable insulation and conductive shield. Cut the conductor squarely; do not pencil. Wire brush bare aluminum conductors and immediately insert them into the crimp barrel which contains inhibitor. Crimp the socket terminal onto the bared conductor, ensuring it remains fully seated. Start crimps at the crimp line and rotate each successive crimp or indent 90 degrees. If using aluminum cable, carefully wipe excess inhibitor from the contact and cable insulation.

  5. Prepare and Clean Insulation

    Remove the semi-conductive shield to a point 7 9/16 inches to 7 5/8 inches back from the end of the pin with a straight, smooth, squared cut. Do not cut or nick the insulation. Pencil the insulation 1/8 inch. Clean the outer jacket and thoroughly clean the insulation to remove all traces of semi-conducting residue by wiping with a rag wet with an approved solvent. Always wipe from the end of the cable toward the outer jacket. If using an ECS or MA grounding device, install it following its appropriate instructions.

  6. Lubricate Receptacle and Cable

    Remove the protective cap from the straight receptacle, keeping the cable insulation and receptacle clean. Apply the supplied lubricant sparingly to the cable and to the inside of the housing. Do not substitute lubricants, as other products may be harmful to this product or its mating product.

  7. Insert Cable into Receptacle

    Push the cable into the housing until the base of the pin chamfer is flush with the inside face of the receptacle. If the receptacle is not to be immediately connected, replace it with an Elastimold insulating plug (K150DP) if an insulating device is required, as the shipping cover only offers protection from dirt and is not an insulating device.

  8. Connect to Mating Plug

    Lubricate the nose of the mating plug with silicone grease. Place the nylon rod into the receptacle face until it bottoms (approximately 1 3/4 inches), taking care to ensure the nylon rod is not cut. Insert the plug assembly into the receptacle as far as possible. Pull out the nylon rod. Secure the electrical connection with the aid of an Elastimold bail. A bailing arrangement is required when this product is used with any mating Elastimold deadbreak product.

  9. Ground the Cable

    If an ELASTIMOLD grounding device is not being used, connect a length of #14 AWG or equivalent copper wire (customer supplied) through the grounding tab and twist tightly. Connect this grounding assembly of the connector to the system ground by merging it with the cable shield of each cable. Seal the grounding wires and connections to prevent corrosion.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.