ABB - Installation Products 167LRT-G5230 - 200 Amp, 15kV, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. Includes 02800X Bi-Metal Contact.

ABB Installation Products 167LRT-G5230 200 Amp, 15kV, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.760 inch to…

UPC: 783786650019


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 167LRT-G5230 is a 200 Amp, 15kV loadbreak bolted elbow connector designed for reliable power distribution applications. This unit features a bolted connection for secure termination and includes a tap for additional connectivity. Engineered for cables with an insulation diameter ranging from 0.760 inches to 0.950 inches, it ensures a precise fit for specified cable sizes. This elbow connector utilizes a bi-metal compression lug, accommodating compressed stranded conductors from AWG #1 up to AWG #1/0, or solid conductors up to AWG #1/0 (42.41 mm²). The bi-metal construction provides excellent conductivity and corrosion resistance for both copper and aluminum conductors. The included 02800X Bi-Metal Contact further enhances the electrical connection's integrity and longevity. Key Specifications: * **SKU:** 167LRT-G5230 * **Manufacturer:** ABB - Installation Products * **Amperage Rating:** 200 Amp * **Voltage Rating:** 15kV * **Cable Insulation Diameter:** 0.760" - 0.950" * **Conductor Size (Compressed Stranded):** AWG #1 to #1/0 (42.41 mm²) * **Conductor Size (Solid):** AWG #1/0 (42.41 mm²) * **Lug Type:** Bi-Metal Compression * **Included Component:** 02800X Bi-Metal Contact
  • 200 Amp, 15kV Loadbreak Bolted Elbow Connector
  • Accommodates cable insulation diameter from 0.760" to 0.950"
  • Bi-metal compression lug for AWG #1 to #1/0 stranded/solid conductors (42.41 mm²)
  • Includes 02800X Bi-Metal Contact for enhanced connection
  • Manufactured by ABB - Installation Products

Specifications

Amperage Rating
200 A
Application
15kV, 200 Amps
Color
Black
Conductor Range
#1 STR/COMPR AWG , 1/0 SOL/COMPT AWG
Environmental Conditions
Fully Submersible
Insulation
True
Material
Housing - EPDM-Rubber
Size
Cable Insulation Diameter 0.760 inch to 0.950 inch
Special Features
Includes 02800X Bi-Metal Contact
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Bolted Elbow with Tap
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
3.0000 L
Package Weight (Metric)
1.3610 kg
600 Amp, 15/25kV, Deadbreak, Straight Receptacle with Test Point, Cable Insulation Diameter .850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #1 or Compacted Solid 1/0.

K656YSR-H0230

600 Amp, 15/25kV, Deadbreak, Straight Receptacle with Test Point, Cable Insulation Diameter .850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #1 or Compacted Solid 1/0.
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.

376LR-J-5260

200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

376LR-H-5240

200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
15kV 200 Amp, Loadbreak Replacement Elbow Connector, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

167RLR-G-5230

15kV 200 Amp, Loadbreak Replacement Elbow Connector, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

274RLR-H-5230

25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

376LR-K-5240

35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
25kV 200 Amp, Loadbreak Replacement Elbow Connector, Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

273RLR-H-5240

25kV 200 Amp, Loadbreak Replacement Elbow Connector, Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

376LR-L-5270

35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

Frequently Asked Questions

What items are included in the 167LRT kit?

The kit includes the elbow connector housing, a compression lug, a stud extender, lubricant, an installation tool, a wrench, installation instructions, and a crimp chart.

What standards does the 167LRT conform to?

The 167LRT conforms to ANSI Std. 386, Fig. 5 and mates with bushing wells conforming to ANSI Std. 386, Fig. 3.

What are the primary applications for the 167LRT?

The 167LRT is designed for connecting to and operating 15kV-class, 95BIL distribution apparatus.

What is the BIL impulse withstand rating?

The 167LRT has a 95kV BIL impulse withstand rating, based on a 1.2 x 50 microsecond wave.

What is the maximum phase-to-phase voltage rating?

The maximum phase-to-phase voltage rating for the 167LRT is 14.4 kV.

What is the maximum phase-to-ground operating voltage?

The maximum phase-to-ground operating voltage for the 167LRT is 8.3 kV.

Is the 167LRT housing submersible?

Yes, the 167LRT features a fully-shielded, fully submersible molded rubber housing when mated with the appropriate connector or insulated cap.

What should cover the loadbreak tap point?

The loadbreak-rated tap point must be covered with an insulated cap when it is not in use.

What is the Elastimold 167LRT Bolted Elbow?

The 167LRT is a loadbreak elbow connector with a loadbreak tap, rated as a 200 AMP, 15kV deadbreak connector.

Is the 167LRT housing submersible?

Yes, the 167LRT features a fully-shielded, fully submersible molded rubber housing when mated with the appropriate connector or insulated cap.

How to Install the 167LRT Loadbreak Bushing Tap

This guide provides step-by-step instructions for the safe installation and initial setup of the 167LRT Loadbreak Bushing Tap, including cable preparation, assembly, and grounding procedures.

Estimated time: 1h 30m

Tools needed:

Wrenches, Installation Tool, Crimp tool, Wire brush, Cable cut back template

Supplies needed:

167LRT Bushing Tap Housing, Compression Lug, Socket Contact, Lubricant (supplied, do not substitute), Well Contact, UD cable (with concentric neutral and semi-con shielding), No. 14 AWG (2.5mm) copper wire, Appropriate connector (for neutral to ground), Elastimold 15kV class 200ampere loadbreak elbow or accessory device, Insulated cap

  1. Prepare for Installation and Train Cable

    DANGER: De-energize all apparatus before beginning installation. This product must be installed only by competent personnel trained in high voltage electrical equipment safety practices. Inspect all parts for damage, rating, and compatibility. Train the UD cable as shown in the diagram to ease operation, ensuring a minimum of 20 inches beyond the end of the cable. Cut excess cable squarely at the center line of the bushing.

  2. Prepare the Cable End

    Unwrap and bind concentric neutral wires 8-1/2 inches back from the end of the cable. Remove the shield and insulation from the cable end, cutting squarely without nicking the conductor. Wire brush bare aluminum conductors and immediately install the compression lug, rotating it to spread inhibitor. Align the compression lug's threaded hole with the bushing bore. Crimp the lug starting at the crimp line mark, rotating 180 degrees for each successive crimp. Carefully wipe excessive inhibitor from the outside of the lug and cable. Remove the semi-con shield as shown in the template. Bevel the insulation end a maximum of 1/8 inch. Thoroughly clean the insulation to remove all traces of conductive residue.

  3. Assemble the Bushing Well Contact

    Thread the well contact onto the bushing well stud by hand, taking care not to cross-thread. Tighten the well contact with the supplied wrench until the wrench bends, signifying that the proper assembly torque has been reached.

  4. Assemble the Bushing Tap Housing

    Remove the protective cap from the bushing tap and the socket contact stored inside. Lubricate the cable insulation and the inside of the bushing housing with the supplied lubricant (DO NOT SUBSTITUTE). Keep insulation clean of dirt and grime, and do not introduce any grease into the gap between the lug and the insulation. Slide the bushing tap onto the cable with a back and forth twisting motion. Wipe off all excess grease. Align the bushing with the compression lug hole. Assemble the socket contact into the bushing tap, ensuring the socket contact stud passes through the lug hole.

  5. Mount the Bushing Tap into the Apparatus Bushing Well

    Inspect the apparatus bushing well to ensure it is dry and free from all contaminants. Lubricate the bushing well interface area of the bushing tap with the supplied lubricant or ELASTIMOLD approved lubricants. Place the lubricated portion of the bushing tap into the apparatus bushing well. Insert the installation tool into the bore of the bushing tap until fully seated. Insert the wrench through the wrench hole of the tool and turn in a clockwise direction until the wrench bends, signifying the proper assembly torque. Remove the wrench and installation tool from the bushing tap.

  6. Connect the Concentric Neutral

    Insert one end of a No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the bushing tap. Twist it tight, taking care not to damage the eye. Twist the neutral wires and connect them to ground using an appropriate connector.

  7. Prepare for Mating Product or Cap Installation

    Thoroughly wipe the bushing tap interface clean of any contaminants. Apply a light, uniform coat of supplied lubricant to the interface, working it thoroughly into the surface. CAUTION: Excess lubricant may prevent a loadbreak elbow from being fully seated in the 'locked on' position. Install the mating products to the bushing tap following the instructions supplied with the mating products. If the bushing tap is not to be immediately mated with an elbow connector, insulated cap, or grounding elbow connector, replace the shipping cap with an appropriate HV insulated cap. Do not energize or submerge the apparatus with the shipping cap, as it is only a protective cover and not insulated or watertight.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.