Authorized ABB Distributor (Installation Products)
ABB - Installation Products K656LR-M2330 - 15/25kV, 600 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.370-1.630 inches (34.798-41.402mm), Copper Lug, Conductor Size 330 - 500kcmil Stranded/Compressed, 600kcmil Solid/Compact. Kit Includes Elbow Connector Housing, Stud, Insulated Plug with Cap, Cable Adapter, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 10.36 x 13.00 inches, 3.38 and 3.83 inch diameters.

ABB Installation Products K656LR-M2330 15/25kV, 600 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter…

UPC: 075114345668


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call (262) 252-1600 or email [email protected] for pricing and availability.

Overview

The ABB K656LR-M2330 is a 15/25kV, 600 Amp deadbreak elbow connector designed for reliable power distribution. This unit features an integrated test point for safe and efficient system diagnostics. It is engineered to accommodate cable insulation diameters ranging from 1.370 to 1.630 inches (34.798-41.402mm). The connector utilizes a copper lug and is suitable for conductor sizes of 330 - 500 kcmil stranded/compressed and 600 kcmil solid/compact. This comprehensive kit includes the elbow connector housing, a stud, an insulated plug with cap, a cable adapter, a V.D. cap (peroxide), a tube of lubricant, a crimp chart, and installation instructions, ensuring a complete installation solution. The physical dimensions of the connector are 10.36 x 13.00 inches, with diameters of 3.38 and 3.83 inches. Key Specifications: - Voltage Rating: 15/25kV - Amperage Rating: 600 Amp - Cable Insulation Diameter Range: 1.370-1.630 inches (34.798-41.402mm) - Lug Material: Copper - Conductor Size Compatibility: 330-500 kcmil Stranded/Compressed, 600 kcmil Solid/Compact - Features: Test Point, Insulated Plug with Cap, V.D. Cap - Manufacturer: ABB - Installation Products - SKU: K656LR-M2330 This deadbreak elbow connector is a critical component for underground distribution systems, providing a secure and insulated connection point for medium voltage cables.
  • 15/25kV voltage rating for medium voltage applications
  • 600 Amp continuous current rating
  • Integrated test point for safe system diagnostics
  • Accommodates cable insulation diameters from 1.370-1.630 inches
  • Copper lug for 330-500 kcmil stranded/compressed and 600 kcmil solid/compact conductors

Specifications

Amperage Rating
600 A
Application
15/25kV, 600 Amp, Deadbreak Connector
Color
Black
Conductor Range
500 kcmil , 600 kcmil
Connection
Push-In
Connection Type
Deadbreak
Current Rating
600 A
Environmental Conditions
All Weather Conditions
Insulation
True
Material
Copper, Poly
Material
Housing - EPDM-Rubber
Series
K
Size
10.36 inch X 13.00 inch from bottom to centerline of bushing, 3.38 inch Diameter
Size
10.36 x 13.00 inches, 3.38 and 3.83 inch diameters
Special Features
15/25kV, 600 Amp Deadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Non-Corrosive Capacitive Voltage Test Point. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector with Test Point
Voltage Rating
15 to 25 kV
Voltage Rating
15/25kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. Cold Shrinkable Seal with Copper Rod and Crimp Connector Included.

K675LR-L-2330-SG1

900 Amp, 15/25kV, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. Cold Shrinkable Seal with Copper Rod and Crimp Connector Included.
6MM2 BLACK CABLE FOR DISTRIBUTION BLOCK ROW TYPE LENGTH 320MM

54211116

6MM2 BLACK CABLE FOR DISTRIBUTION BLOCK ROW TYPE LENGTH 320MM
Solenoid Valve Connectors, Accessory, Thumb screw, Cabled Form A, B, ISB, and FW ISC

V-25TB

Solenoid Valve Connectors, Accessory, Thumb screw, Cabled Form A, B, ISB, and FW ISC
35kV, 200 Amp, Loadbreak Elbow without Test Point, with Seal. Cable Insulation Diameter 0.850 - 1.050 inches (21.59-26.67mm). Copper Compression Lug. Conductor Size 260 - 3/0 Stranded/Compressed or 4/0 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Tube of Lubricant, Crimp Chart and Installation Instructions.

375LR-H2260-S

35kV, 200 Amp, Loadbreak Elbow without Test Point, with Seal. Cable Insulation Diameter 0.850 - 1.050 inches (21.59-26.67mm). Copper Compression Lug. Conductor Size 260 - 3/0 Stranded/Compressed or 4/0 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Tube of Lubricant, Crimp Chart and Installation Instructions.
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded 2/0, Solid 3/0, mmSquared 67.43. 200ECS Cold-Shrinkable Jacket Seal Included.

376LR-K2250-S

200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded 2/0, Solid 3/0, mmSquared 67.43. 200ECS Cold-Shrinkable Jacket Seal Included.
25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 4/0 Stranded Wire Size, Copper Compression Lug.

262LR-D2270

25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 4/0 Stranded Wire Size, Copper Compression Lug.
25/28kV, 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090-1.310 inches (27.68-33.27mm), Copper Lug, Conductor Size 270 - 4/0 Stranded/Compressed, 250 kcmil Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Tube of Lubricant, Crimp Chart and Installations Instructions. 9.03 x 8.20 inches, 2.86 inch diameter.

262LR-E2270

25/28kV, 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090-1.310 inches (27.68-33.27mm), Copper Lug, Conductor Size 270 - 4/0 Stranded/Compressed, 250 kcmil Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Tube of Lubricant, Crimp Chart and Installations Instructions. 9.03 x 8.20 inches, 2.86 inch diameter.
25/28kV, 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.890-1.220 inches (22.61-30.99mm), Copper Lug, Conductor Size 260 - 3/0 Stranded/Compressed, 4/0 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Tube of Lubricant, Crimp Chart and Installations Instructions. 9.03 x 8.20 inches, 2.86 inch diameter.

262LR-D2260

25/28kV, 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.890-1.220 inches (22.61-30.99mm), Copper Lug, Conductor Size 260 - 3/0 Stranded/Compressed, 4/0 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Tube of Lubricant, Crimp Chart and Installations Instructions. 9.03 x 8.20 inches, 2.86 inch diameter.

Frequently Asked Questions

What is the maximum operating voltage for the K656LR elbow connector?

The K656LR is designed for up to 28kV, with a maximum phase-to-ground operating voltage of 16.2kV and phase-to-phase of 28kV.

What conductor sizes can the K656LR accommodate?

It supports aluminum and copper conductors ranging from #2 AWG to 1250 kcmil.

What is the continuous current rating for this deadbreak elbow?

The K656LR has a continuous current rating of 600 Amps.

Is a grounding device recommended when using the K656LR?

Yes, a grounding device for safety is highly recommended when used on metallic tape shield or drain wire cable.

What is the impulse withstand rating for the 28kV voltage class?

For the 28kV voltage class, the impulse withstand is 140kV BIL (1.2 x 50 microsecond wave).

What is the AC one-minute withstand voltage for the 15kV class?

The 15kV voltage class has an AC one-minute withstand rating of 34kV.

What is the corona extinction level for the 28kV voltage class?

The corona extinction level for the 28kV voltage class is 21.5kV AC at 3pC sensitivity.

What is the range of insulation diameters supported by the K656LR?

The K656LR supports cable insulation diameters from 0.640 inches to 1.935 inches.

What is the momentary current withstand rating?

The K656LR has a momentary current withstand rating of 25kA Sym for 10 Cycles.

Can the K656LR be installed with standard tools?

Yes, it can be easily connected or disconnected using standard hand tools and equipment in a de-energized state.

How to Install K655/K675LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe installation and wiring of K655/K675LR deadbreak elbow connectors on high voltage apparatus, including cable preparation and final assembly. Ensure all apparatus are de-energized before beginning installation.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Crimping tool, Wire brush (for aluminum conductors), Hotstick, Suitable sensing device (for capacitive test points), Torque wrench

Supplies needed:

K655/K675LR Elbow Connector kit (includes Elbow, Cable Adapter, Compression Lug, Insulating Plug, Lubricant, Stud Prepack), No. 14 AWG Copper wire (or equivalent ampacity), Suitable ground connector, Silicone lubricant, Waterproofing material (for cable jacket)

  1. Ensure Safety and Prepare for Installation

    DANGER: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products. Inspect all parts for damage, proper rating, and compatibility with mating parts. Read all instructions completely before starting and have all required tools at hand. Maintain cleanliness throughout the procedure.

  2. Assemble Cable and Clean Outer Surface

    Assemble the cable in its final position, ensuring enough slack to remove elbows. For concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4 inches (45mm) from the centerline of the mating product. Clean the outer surface of the cable for a distance of 24 inches (610mm) or up to the bent back concentric neutral wires.

  3. Prepare the Cable End

    Remove the outer jacket (if applicable) and prepare the cable according to the specific type (e.g., non-jacketed concentric neutral, jacketed shield wires, flat metallic tape shield, fabric tape shield, or longitudinally corrugated shield). Refer to the provided diagrams for precise dimensions for cable insulation, semi-con shield, and tape marker placement. If using a 20MA/21MA grounding device, 600ECS Jacket Cable Seal, or 10TL cable shield adapter, refer to their specific installation instructions for cable preparation.

  4. Install the Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and then lubricate the cable insulation, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  5. Expose the Conductor

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Be careful not to cut or nick the cable adapter or the conductor. The length of the exposed conductor should be between 4-1/4 inches and 4-9/16 inches (108mm-116mm). If the length is outside this range, redo the assembly.

  6. Install and Crimp the Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor and immediately fully insert it into the compression lug. Measure the 'Check Dimension' before crimping; it should be less than 6-3/8 inches. Crimp the compression lug following the instructions supplied with the lug. Wipe all excess inhibitor from the lug and cable adapter surface after crimping. The distance from the end of the compression lug to the cable adapter after crimping should be between 6-3/8 inches to 7-1/8 inches (162mm-181mm). If dimensions are incorrect, redo the assembly.

  7. Install the Elbow Connector

    Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter remains flush with the tape marker. If not, reposition the cable adapter. Remove the tape marker.

  8. Prepare Mating Products

    DANGER: Do not connect or disconnect mating products while energized. Do not energize while disconnected. Remove protective caps from both the elbow and the mating part. Hand tighten the threaded stud supplied with the elbow into the mating part, if the mating part is not already equipped with a stud. Clean and lubricate both the elbow and the mating part with the supplied lubricant, ensuring surfaces remain clean.

  9. Connect Elbow to First Mating Part

    Push the elbow onto the mating part, carefully lining up the hole in the compression lug with the stud on the mating part.

  10. Connect Elbow to Second Mating Part or Insulating Plug

    Clean and lubricate the mating part for the opposite end of the elbow. Insert this mating part into the elbow. Engage the threads and hand tighten. Torque the mating part according to the instructions supplied with that specific mating part. If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap and place it on the elbow, pushing down hard until the cap snaps into place.

  11. Ground the Cable Shield

    Insert one end of a piece of wire with ampacity at least equivalent to No. 14 AWG Copper through the grounding eye and twist to make a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. The shield of the cable must be grounded; follow instructions supplied with any grounding device or use an alternate method. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.

  12. Perform Final Torque Check

    CAUTION: When constructing 600-amp L-Kits, ensure each component is tightened to the specified torque per the instructions provided with the individual components.

  13. Perform Voltage Test (Optional but Recommended)

    The ELASTIMOLD deadbreak elbow connector has an integral capacitance test point. To use it, remove the test point cap with a hotstick, peeling it off at an angle. WARNING: This is a capacitance device, not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device designed for capacitive test points to determine if the cable is energized. Contamination or incorrect equipment can give false readings; treat the elbow as energized until confirmed otherwise by other means. After testing, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.