ABB - Installation Products 162LR-C2270 - 200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

ABB Installation Products 162LR-C2270 200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060…

UPC: 075114187947


Documents & Media
BrochureInstallation InstructionsManufacturer Product Website

Contact for Pricing

Call (262) 252-1600 or email [email protected] for pricing and availability.

Overview

The ABB 162LR-C2270 is a 200 Amp, 15kV loadbreak elbow connector engineered for medium-voltage power distribution systems. This connector is designed to provide a reliable, load-interruptible connection point for cable insulation diameters ranging from 0.805 inches to 1.060 inches. The 162LR-C2270 features a copper compression lug for secure conductor termination, supporting compressed stranded conductors up to 4/0 AWG and solid conductors up to 250 AWG (126.67 mm²). Key applications include utility substations, industrial power distribution, renewable energy systems, and commercial facilities requiring safe, high-voltage cable connections. The loadbreak design allows for hot-swapping of cables under load, minimizing downtime during maintenance or reconfiguration. The connector is part of ABB's Installation Products line, known for durable, field-proven components in medium-voltage systems. The 162LR-C2270 is optimized for compatibility with 15kV class systems, ensuring electrical integrity and operational safety. Its robust construction supports long-term reliability in harsh environments, including outdoor installations subject to moisture, dust, and mechanical stress. The connector's design aligns with industry standards for medium-voltage cable accessories, providing a standardized interface for utility and industrial applications. For precise installation, the connector requires matching cable insulation diameters and conductor sizes. The catalog number selection process involves determining the insulation diameter code (C for 0.805-1.060"), material code (5 for copper), and compression lug code (270 for 4/0 AWG compressed stranded or 250 solid).
  • 200 Amp, 15kV rated for medium-voltage power distribution
  • Accommodates cable insulation diameters from 0.805" to 1.060"
  • Copper compression lug supports 4/0 AWG stranded or 250 AWG solid conductors
  • Loadbreak design enables hot-swapping under load for reduced downtime
  • Part of ABB Installation Products line for utility and industrial applications

Specifications

Amperage Rating
200 A
Application
15kV, 200 Amp
Color
Black
Conductor Range
4/0 STR/COMPR AWG , 250 kcmil
Connection
Push-In
Connection Type
Compression Lug
Current Rating
200 A
Environmental Conditions
All Weather Conditions
Insulation
True
Material
Copper
Material
Housing - EPDM-Rubber
Series
162LR
Size
0.805-1.060 inch (cable insulation diameter), 4/0 AWG Compressed Stranded / 250 AWG Solid (126.67 mm²)
Size
7.76 inch (197.1 mm) X 9.03 inch (229.4 mm), 2.92 inch (74.2 mm) Diameter
Special Features
15kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard. Non-corrosive capacitive test point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector with Test Point
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.

162LR-C5270-S

200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.
6MM2 BLACK CABLE FOR DISTRIBUTION BLOCK ROW TYPE LENGTH 320MM

54211116

6MM2 BLACK CABLE FOR DISTRIBUTION BLOCK ROW TYPE LENGTH 320MM
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, 2/0 Stranded Wire Size, Bi-Metal Compression Lug

162LR-B5250

15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, 2/0 Stranded Wire Size, Bi-Metal Compression Lug
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, 2/0 Stranded Wire Size, Copper Compression Lug

162LR-C2250

15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, 2/0 Stranded Wire Size, Copper Compression Lug
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, 3/0 Stranded Wire Size, Bi-Metal Compression Lug

162LR-B5260

15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, 3/0 Stranded Wire Size, Bi-Metal Compression Lug
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS Jacket Seal Included.

162LR-B5250-S

200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS Jacket Seal Included.
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS-G3 Jacket Seal and Grounding Kit Included.

162LR-B5250-SG3

200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS-G3 Jacket Seal and Grounding Kit Included.
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS-G3 Jacket Seal and Grounding Kit Included.

162LR-B5240-SG3

200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS-G3 Jacket Seal and Grounding Kit Included.

Frequently Asked Questions

What standards does this product comply with?

The Elastimold 200 amp loadbreak elbow is IEEE 386 compliant and has ANSI certification, in addition to Rural Utilities Service (RUS) acceptance.

Is the Elastimold loadbreak elbow RUS accepted?

Yes, the enhanced Elastimold 200 amp loadbreak elbow has Rural Utilities Service (RUS) acceptance from the U.S. Department of Agriculture (USDA), authorizing its use in rural infrastructure construction.

What are the voltage ratings for this loadbreak elbow?

The Elastimold 200 amp loadbreak elbow is available in 15 kV and 25 kV series.

What product is described in this document?

This document describes the enhanced Elastimold 200 amp loadbreak elbow, available in 15 kV and 25 kV series.

What standards does this product comply with?

The Elastimold 200 amp loadbreak elbow is IEEE 386 compliant and has ANSI certification, in addition to Rural Utilities Service (RUS) acceptance.

Is the Elastimold loadbreak elbow RUS accepted?

Yes, the enhanced Elastimold 200 amp loadbreak elbow has Rural Utilities Service (RUS) acceptance from the U.S. Department of Agriculture (USDA), authorizing its use in rural infrastructure construction.

What are the voltage ratings for this loadbreak elbow?

The Elastimold 200 amp loadbreak elbow is available in 15 kV and 25 kV series.

What product is described in this document?

This document describes the enhanced Elastimold 200 amp loadbreak elbow, available in 15 kV and 25 kV series.

What standards does this product comply with?

The Elastimold 200 amp loadbreak elbow is IEEE 386 compliant and has ANSI certification, in addition to Rural Utilities Service (RUS) acceptance.

What product is described in this document?

This document describes the enhanced Elastimold 200 amp loadbreak elbow, available in 15 kV and 25 kV series.

How to Install 161LR/162LR Loadbreak Elbow Connectors

This guide provides step-by-step instructions for preparing cables, assembling the elbow connector, grounding, and connecting the 161LR or 162LR Loadbreak Elbow Connector to a 15kV class bushing.

Estimated time: 1h 30m

Tools needed:

Probe Wrench, Cable cutting tool, Wire strippers, Cable knife, Measuring tape, Wire brush, Crimp tool, Insulated hotstick

Supplies needed:

161LR or 162LR Elbow Connector Housing, Compression Lug, Probe, Lubricant (supplied with kit), No. 14 AWG (2.5mm) copper wire, Appropriate connector (for neutral to ground), Vinyl tape (if applicable), Conductive copper tape (if applicable), Cold shrink tube/sealing kit (if applicable)

  1. Perform Initial Checks and Ensure Safety

    DANGER: All apparatus must be de-energized during installation or removal of parts. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Before starting, confirm all apparatus are de-energized. Inspect the contents of the package to ensure all components (Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant) are complete and undamaged. Check all components for proper fit with the cable and mating products. Thread the probe into the compression lug by hand to check for resistance; if encountered, replace damaged components. Ensure all required tools are at hand and maintain cleanliness throughout the procedure.

  2. Prepare the Cable for Termination

    Train the cable to ensure adequate slack for future operation. Depending on your cable type (non-jacketed/jacketed concentric neutral, jacketed with drain wires, or jacketed copper tape shield), prepare the neutral or ground wires and cut the cable squarely at the centerline of the bushing. Refer to the specific instructions for your cable type to remove the outer jacket and prepare the neutral/ground wires (e.g., remove 9-5/8” (240mm) of outer jacket, unwrap and bind neutral/ground wires, or wrap copper tape).

  3. Prepare the Cable Conductor and Install Compression Lug

    Remove the insulation shield and insulation 2-1/8” (55mm) from the cable end, cutting squarely without nicking the conductor. Wire brush the bare aluminum conductors thoroughly and immediately install the compression lug. Rotate the lug to spread any inhibitor. Position the compression lug so its contact threaded hole aligns with the bushing bore. Crimp the lug according to the manufacturer's chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe off any excess inhibitor. Remove the insulation shield as shown in the diagrams, and bevel the insulation end by a maximum of 1/8” (5mm). Thoroughly clean the insulation to remove all traces of dirt or excess inhibitor.

  4. Assemble the Elbow Connector

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant. DO NOT SUBSTITUTE other lubricants. Slide the elbow connector onto the cable using a back-and-forth twisting motion, then wipe off all excess lubricant. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends, indicating proper torque.

  5. Ground the Elbow Connector

    Insert one end of a separate No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the elbow and twist it tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack in the wires for elbow operation. If using a cold shrink grounding kit, refer to its specific instructions.

  6. Connect the Elbow to the Bushing Plug

    CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED before proceeding. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Operate the connection using a full insulated 'hotstick' type tool. DO NOT OPERATE BY HAND. Securely fasten the hotstick to the loadbreak connector pulling eye and insert the elbow connector into the bushing with a fast, firm, straight motion, applying sufficient force to engage the internal lock. WARNING: Always confirm de-energized status before making connections. Use appropriate insulated tools for operation.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.