ABB Installation Products 162LR-C5210 15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable…
UPC: 075114187954
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15kV voltage rating
- 200 Amp current rating
- Includes test point for safe voltage verification
- Accommodates cable insulation diameters from .805 to 1.060 inches
- Bi-metal compression lug for #3 stranded wire
Specifications
Amperage Rating | 200 A |
Application | 15kV, 200 Amp |
Color | Black |
Conductor Range | #3 STR/COMPR AWG , #2 SOL/COMPT AWG |
Connection | Push-In |
Environmental Conditions | All Weather Conditions |
Insulation | True |
Material | Housing - EPDM-Rubber |
Size | 7.76 inch (197.1 mm) X 9.03 inch (229.4 mm), 2.92 inch (74.2 mm) Diameter |
Special Features | 15kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard. Non-corrosive capacitive test point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector with Test Point |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

K151SR-A0210
15/25kV 200 Amp, Deadbreak Straight Receptacle, Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size #3 Compressed or Stranded AWG, or #2 Solid or Compact AWG or 26.67 mm2. Bails are required, but not included, order separately. Length 9.54 inch. Widest point 2.74 inch.
162LR-C-5220-S
15kV, 200 Amp, Loadbreak Elbow with Sealing Kit with Test Point. Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1. 200ECS Jacket Seal Included.
162LR-C2270
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
162LR-B5250
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, 2/0 Stranded Wire Size, Bi-Metal Compression Lug
162LR-C2250
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, 2/0 Stranded Wire Size, Copper Compression Lug
162LR-B5260
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, 3/0 Stranded Wire Size, Bi-Metal Compression Lug
162LR-B5250-S
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS Jacket Seal Included.
162LR-B5250-SG3
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS-G3 Jacket Seal and Grounding Kit Included.Frequently Asked Questions
Why does the elbow have rigid probe support?
The rigid probe support ensures proper switching and easy probe installation.
Is an integral jacket seal available for the elbow?
Yes, the enhanced Elastimold 200 amp loadbreak elbow offers an optional integral jacket seal.
What material is the pulling eye made from?
The elbow features a robust stainless-steel pulling eye, which promotes durable hotstick control.
Does the elbow feature a no-stick interface?
Yes, it incorporates a no-stick interface when used with Elastimold bushings, which has been NEETRAC tested.
What standards and certifications does the elbow meet?
The product is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance.
Does the enhanced elbow have RUS acceptance?
Yes, the enhanced Elastimold 200 amp loadbreak elbow has Rural Utilities Service (RUS) acceptance from the USDA.
What safety features are included in the enhanced elbow?
It features improved insulation for 15 kV elbows, rigid probe support, a no-stick interface with Elastimold bushings, a robust stainless-steel pulling eye, and dual grounding eye positions.
What are the voltage ratings for this elbow?
The enhanced Elastimold 200 amp loadbreak elbow is designed for 15 kV and 25 kV series applications.
What is the Elastimold 200 amp loadbreak elbow?
It is an enhanced loadbreak elbow for 15 kV and 25 kV systems, designed for switching operations with improved safety, flexibility, and reduced life cycle costs.
Why does the elbow have rigid probe support?
The rigid probe support ensures proper switching and easy probe installation.
How to Install Elastimold 161LR/162LR Loadbreak Elbow Connectors
This guide provides step-by-step instructions for the safe and proper installation of Elastimold 161LR and 162LR Loadbreak Elbow Connectors, including cable preparation, elbow assembly, grounding, and connection to a bushing.
Estimated time: 1h
Tools needed:
Probe Wrench, Hotstick (live-line tool), Wire brush, Crimp tool, Wire strippers, Suitable sensing device (for 162LR capacitive test points)
Supplies needed:
161LR or 162LR Loadbreak Elbow Connector Kit (includes Elbow Housing, Compression Lug, Probe, Lubricant), Copper wire (No. 14 AWG / 2.5mm), Appropriate connector (for neutral/ground), HV insulated cap(s) or connector(s) (if replacing shipping covers), Conductive copper tape (if applicable), Cold shrink tube (if applicable), Vinyl tape (if applicable)
- Perform Initial Safety Checks and Component Verification
DANGER: Ensure all apparatus are de-energized during installation or removal of parts, except for test point caps and indicators. Do not touch or move energized products. Inspect all parts for damage, proper rating, and compatibility with mating parts. Check package contents for completeness. Verify proper fit of components with the cable and/or mating products. Test fit the probe into the compression lug by threading it in, ensuring it turns freely for approximately four turns before becoming snug. Remove any protective shipping covers and replace with appropriate HV insulated caps or connectors before submerging or energizing the circuit. Have all required tools at hand and maintain cleanliness throughout the procedure.
- Train Cable and Perform Initial Preparation
Train the cable to ensure adequate slack for ease of operation. Prepare the concentric neutral wires or grounding braid wire according to your specific cable type (non-jacketed, jacketed, drain wires, or copper tape shield), ensuring extra length for connection to the tank ground. Cut the excess cable squarely at the centerline of the bushing. Perform any specific jacket or shield removal and preparation (e.g., removing outer jacket, unwrapping drain wires, removing copper tape shield, applying conductive copper tape or cold shrink tube) as required for your cable type, referring to the detailed diagrams in the full instructions.
- Prepare Conductor and Insulation
Remove 2-1/8” (55mm) of the shield and insulation from the cable end, cutting squarely and taking care not to nick the conductor. Wire brush bare aluminum conductors and immediately install the compression lug. Rotate the lug to spread inhibitor. Position the compression lug so its contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart packaged with the compression lug, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe excess inhibitor from the outside of the lug and cable. Remove 6-7/8” (175mm) of the insulation shield. Bevel the insulation end 1/8” (5mm) maximum. Thoroughly clean the insulation to remove all traces of dirt or excess inhibitor.
- Assemble the Elbow Connector
Lubricate the cable insulation and the inside of the elbow housing with the lubricant supplied in the kit. DO NOT SUBSTITUTE, as other lubricants may be harmful. Keep insulation clean of dirt and grime. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off all excess lubricant. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, taking care not to cross-thread. The probe must turn freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends.
- Connect Grounding Wires
Insert one end of a separate copper wire (No. 14 AWG / 2.5mm or equivalent) through the grounding eye on the elbow. Twist it tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Provide adequate slack in the wires for elbow operation. If using a cold shrink grounding kit, refer to its specific instructions to complete the installation.
- Connect Elbow to Bushing (Loadmake Operation)
DANGER: CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED BEFORE PROCEEDING WITH LUBRICATION AND CONNECTION. Lubricate the receptacle portion of the elbow connector and the mating bushing with the lubricant supplied. Prepare the bushing for the elbow connector by removing its insulated cap using a hotstick tool. Securely fasten the hotstick to the loadbreak connector pulling eye. Confirm positive control of the elbow connector. Insert the probe tip approximately 2” (50mm) into the bushing. DO NOT HOLD IN THIS POSITION. Immediately push the elbow home with a fast, firm, straight motion, using sufficient force to engage the internal lock on the elbow connector and bushing interface.
- Perform Voltage Test (162LR only, Optional)
For 162LR connectors equipped with an integral capacitance test point, remove the test point cap with a hotstick, peeling it off at an angle rather than pulling directly in line. WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Follow the manufacturer’s directions for the meter used. Test with a suitable sensing device, made for use with separable connectors manufactured with capacitive test points, to determine if the cable is energized. Treat the elbow as energized until the “no voltage” test point indication is confirmed by other means. After voltage detection, clean the inside surface of the cap, lubricate it with silicone lubricant, and replace it on the test point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.