ABB Installation Products 162LR-B5270 15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable…
UPC: 075114187916
Documents & Media
Contact for Pricing
Minimum Qty: 15
Multiplier: 15
*Contact for lower quantities*
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15kV voltage rating with 200 Amp current capacity
- Integrated test point for safe circuit diagnostics without load disconnection
- Accommodates cable insulation diameters from 0.635" to 0.905"
- Specified for 4/0 stranded wire with bi-metal compression lug
- Loadbreak elbow design enables hot-stick operation for live-line maintenance
Specifications
Amperage Rating | 200 A |
Application | 15kV, 200 Amp |
Color | Black |
Conductor Range | 4/0 STR/COMPR AWG , 250 kcmil |
Connection | Push-In |
Connection Type | Compression Lug |
Current Rating | 200 A |
Environmental Conditions | All Weather Conditions |
Insulation | True |
Material | Bi-Metal Compression Lug |
Material | Housing - EPDM-Rubber |
Series | 162LR |
Size | 0.635 inch to 0.905 inch (Cable Insulation Diameter) |
Size | 7.76 inch (197.1 mm) X 9.03 inch (229.4 mm), 2.92 inch (74.2 mm) Diameter |
Special Features | 15kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard. Non-corrosive capacitive test point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector with Test Point |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 2.0200 L |
Package Weight (Metric) | 0.9160 kg |

162LR-C5270-S
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.
162LR-C5210
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #3 Stranded Wire Size, Bi-Metal Compression Lug
162LR-C-5220-S
15kV, 200 Amp, Loadbreak Elbow with Sealing Kit with Test Point. Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1. 200ECS Jacket Seal Included.
162LR-C2270
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
162LR-B5250
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, 2/0 Stranded Wire Size, Bi-Metal Compression Lug
162LR-C2250
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, 2/0 Stranded Wire Size, Copper Compression Lug
162LR-B5260
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, 3/0 Stranded Wire Size, Bi-Metal Compression Lug
162LR-B5250-S
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS Jacket Seal Included.Frequently Asked Questions
What does RUS acceptance mean for this product?
Rural Utilities Service (RUS) acceptance from the USDA authorizes its use in rural infrastructure construction and improvements.
What is the benefit of the stainless-steel pulling eye?
The robust stainless-steel pulling eye promotes durable hotstick control.
What is the purpose of the rigid probe support?
The internal rigid probe support ensures proper switching and easy probe installation.
What certifications does the loadbreak elbow have?
The product is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance from the USDA.
What safety features does the enhanced elbow offer?
It includes improved insulation for 15 kV elbows, rigid probe support, a no-stick interface with Elastimold bushings, a robust stainless-steel pulling eye, and dual grounding eye positions.
What are the voltage ratings for this elbow?
The Elastimold 200 amp loadbreak elbow is available for 15 kV and 25 kV applications.
What is the Elastimold 200 amp loadbreak elbow?
It is an enhanced 200 amp loadbreak elbow available for 15 kV and 25 kV series, designed for switching operations.
What certifications does the loadbreak elbow have?
The product is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance from the USDA.
What is the benefit of the stainless-steel pulling eye?
The robust stainless-steel pulling eye promotes durable hotstick control.
What is the purpose of the rigid probe support?
The internal rigid probe support ensures proper switching and easy probe installation.
How to Install 161LR and 162LR Loadbreak Elbow Connectors
This guide provides step-by-step instructions for the safe installation and initial setup of 161LR and 162LR Loadbreak Elbow Connectors, designed for terminating UD cables and connecting to 15kV class loadbreak bushings.
Estimated time: 1h 30m
Tools needed:
Probe Wrench, Wire brush, Crimp tool, Cable cutter, Cable stripping tool, Hotstick tool
Supplies needed:
161LR or 162LR Elbow Connector Housing, Compression Lug, Probe, Lubricant (supplied with kit), No. 14 AWG (2.5mm) copper wire or equivalent, Appropriate neutral wire connector, Conductive copper tape (if required), Vinyl tape (if required), Cold shrink tube (if required), HV insulated caps or connectors (if replacing shipping covers)
- Perform Pre-Installation Checks and Safety Procedures
Before starting, ensure all apparatus is de-energized. This product must be installed by competent personnel trained in high voltage safety practices. Inspect all package contents for completeness and damage. Verify all components fit properly with the cable and mating products. Check the probe threads by hand-threading it into the compression lug; replace if resistance is encountered. If the product has shipping covers, remove them and replace with appropriate HV insulated caps or connectors before energizing.
- Prepare the Cable for Initial Termination
Train the cable to ensure adequate slack for operation. Based on your cable type (non-jacketed concentric neutral, jacketed concentric neutral, jacketed with drain wires, or jacketed copper tape shield), follow the specific instructions in the product manual for initial jacket removal, neutral wire management, and application of any sealing kits. Ensure extra length of neutral or grounding braid wire is available for connection to tank ground.
- Prepare the Conductor and Insulation
Remove 2-1/8 inches (55mm) of the shield and insulation from the cable end, cutting squarely without nicking the conductor. Wire brush bare aluminum conductors thoroughly and immediately install the compression lug. Ensure the lug's threaded hole aligns with the bushing bore. Crimp the lug according to the manufacturer's chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe off any excess inhibitor. Remove the insulation shield 6-7/8 inches (175mm) from the cable end, ensuring a straight, smooth, and squared cut. Bevel the insulation end a maximum of 1/8 inch (5mm). Thoroughly clean the insulation to remove all dirt or excess inhibitor.
- Assemble the Elbow Connector
Lubricate the cable insulation and the inside of the elbow housing using only the supplied lubricant; do not substitute. Slide the elbow connector onto the cable with a back-and-forth twisting motion, then wipe off any excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends, indicating proper torque.
- Connect Grounding and Neutral Wires
Insert one end of a separate No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the elbow and twist tightly, being careful not to damage the eye. If the elbow is pre-ordered with a ground wire, skip this. Twist all concentric neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack for elbow operation. If using a cold shrink grounding kit, refer to its specific instructions.
- Connect the Elbow to the Bushing
CONFIRM THAT BOTH THE TRANSFORMER AND THE ELBOW ARE DE-ENERGIZED before proceeding. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a hotstick to the loadbreak connector pulling eye. Insert the probe tip approximately 2 inches (50mm) into the bushing, then immediately push the elbow home with a fast, firm, straight motion to engage the internal lock. Do not operate by hand.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.