ABB Installation Products 162LR-C2250 15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable…
UPC: 075114187930
Documents & Media
Contact for Pricing
Call (262) 252-1600 or email [email protected] for pricing and availability.
Overview
- 15kV Voltage Rating
- 200 Amp Current Rating
- Integrated Test Point for Safe Testing
- Accommodates 0.805" - 1.060" Cable Insulation Diameter
- Designed for 2/0 Stranded Wire with Copper Compression Lug
Specifications
Amperage Rating | 200 A |
Application | 15kV, 200 Amp |
Color | Black |
Conductor Range | 2/0 STR/COMPR AWG , 3/0 SOL/COMPT AWG |
Connection | Push-In |
Environmental Conditions | All Weather Conditions |
Insulation | True |
Material | Housing - EPDM-Rubber |
Size | 7.76 inch (197.1 mm) X 9.03 inch (229.4 mm), 2.92 inch (74.2 mm) Diameter |
Special Features | 15kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard. Non-corrosive capacitive test point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector with Test Point |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

162LR-B5250-SG3
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS-G3 Jacket Seal and Grounding Kit Included.
162LR-B5260
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, 3/0 Stranded Wire Size, Bi-Metal Compression Lug
162LR-B5250-S
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS Jacket Seal Included.
162LR-B5240-SG3
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS-G3 Jacket Seal and Grounding Kit Included.
162LR-B5240(CTN)
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
162LR-B-5240
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, 1/0 Stranded Wire Size, Bi-Metal Compression Lug
162LR-B-5240-S
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS Jacket Seal Included.Frequently Asked Questions
Is an optional integral jacket seal available?
Yes, the enhanced design includes an optional integral jacket seal.
What is the Elastimold 200 amp loadbreak elbow?
It is an enhanced 200 amp loadbreak elbow for 15 kV and 25 kV series, designed for switching operations. It incorporates innovative design and manufacturing experience.
What are the voltage ratings for this loadbreak elbow?
The Elastimold 200 amp loadbreak elbow is designed for 15 kV and 25 kV series applications.
What safety features are included in the enhanced elbow?
It features improved insulation for 15 kV elbows, rigid probe support, a no-stick interface with Elastimold bushings, a robust stainless-steel pulling eye, and dual grounding eye positions.
Is the elbow compatible with Elastimold bushings?
Yes, it features a no-stick interface when used with Elastimold bushings, which has been NEETRAC tested.
What certifications and standards does the product meet?
The product is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance from the USDA.
Does the Elastimold elbow have RUS acceptance?
Yes, the enhanced Elastimold 200 amp loadbreak elbow has Rural Utilities Service (RUS) acceptance from the U.S. Department of Agriculture (USDA).
What flexibility improvements does the enhanced design offer?
The enhanced design offers additional sizes, improved wider cable ranges, an easy order system, and an optional integral jacket seal.
How does the enhanced elbow reduce life cycle costs?
It is optimized for switching operations, offers lifetime ease of operation, is non-stick with Elastimold bushings, and has an improved seal system.
What material is the pulling eye made from?
The pulling eye is made from robust stainless steel, promoting durable hotstick control.
How to Install 161LR and 162LR Loadbreak Elbow Connectors
This guide provides detailed instructions for the installation and initial setup of 161LR and 162LR Loadbreak Elbow Connectors, including cable preparation, elbow assembly, and grounding.
Estimated time: 1h 30m
Tools needed:
Probe Wrench, Wire brush, Crimp tool, Hotstick
Supplies needed:
Lubricant (Do Not Substitute), Copper wire (No. 14 AWG / 2.5mm or equivalent), Appropriate connector for neutral wires, Cable sealing kit components (if applicable)
- Perform initial checks and train cable
DANGER: All apparatus must be de-energized during installation. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Inspect the package contents to ensure all parts are complete and undamaged. Verify all components fit properly with the cable and/or mating products. Thread the probe into the compression lug to check for resistance; replace damaged components if resistance is encountered. Train the cable to ensure adequate slack for future operation. Based on cable type, prepare the cable by pulling extra length for neutral wires/grounding braid, removing the outer jacket, and binding/folding back ground wires as specified. If using a cold shrink sealing kit, slide the cold shrink tube onto the cable. Cut the excess cable squarely at the centerline of the bushing.
- Prepare cable for lug installation
Remove the shield and insulation 2-1/8 inches (55mm) from the cable end, ensuring a square cut without nicking the conductor. Wire brush bare aluminum conductors immediately and install the compression lug. Rotate the lug to spread the inhibitor. Align the compression lug's contact threaded hole with the bushing bore. Crimp the lug starting at the crimp line mark, rotating 180 degrees for each successive crimp (refer to crimp chart for tool information). Carefully wipe excess inhibitor from the outside of the lug and cable. Remove the insulation shield as shown in the diagram, and bevel the insulation end a maximum of 1/8 inch (5mm). Thoroughly clean the insulation to remove all traces of dirt or excess inhibitor.
- Assemble the elbow connector
Lubricate the cable insulation and the inside of the elbow housing using ONLY the supplied lubricant. DO NOT SUBSTITUTE, as other lubricants may be harmful to this product or its mating product(s). Keep insulation clean of dirt and grime. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off all excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten with the supplied wrench until the wrench bends.
- Connect grounding and neutral wires
Insert one end of a separate copper wire (No. 14 AWG / 2.5mm or equivalent) through the grounding eye on the elbow. Twist tightly, taking care not to damage the eye. If the elbow is preordered with ground wire, continue to the concentric neutral connection section. Twist all neutral wires together and connect them to ground using an appropriate connector. Ensure adequate slack in the wires for elbow operation. If using a cold shrink grounding kit, refer to the instructions supplied with the grounding kit to complete the installation.
- Connect the elbow to the bushing plug
WARNING: CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED before proceeding with this step. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a hotstick to the loadbreak connector pulling eye. Insert the probe tip approximately 2 inches (50mm) into the bushing (at this point the contacts are approximately 4 inches apart). Immediately push the elbow home with a fast, firm, straight motion to engage the internal lock on the elbow connector and bushing interface. DO NOT HOLD IN THE PARTIALLY INSERTED POSITION. Do not operate by hand; use a full insulated 'hotstick' type tool.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.