ABB - Installation Products 162LR-B-5220 (CTN) - 200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
ABB - Installation Products

162LR-B-5220 (CTN)

UPC: 075114186421


Documents & Media
BrochureInstallation InstructionsManufacturer Product Website

Contact for Pricing

Overview

The ABB 162LR-B-5220 (CTN) is a 200 Amp, 15kV loadbreak elbow connector designed for medium-voltage electrical distribution systems. It includes a built-in test point for safe circuit verification without de-energizing the system, enhancing maintenance and troubleshooting efficiency. The connector supports cable insulation diameters from 0.635 to 0.905 inches, accommodating common utility and industrial cable sizes. It features a bi-metal compression lug compatible with compressed stranded AWG #2 or solid AWG #1 conductors, with a cross-sectional area of 33.62 mm². The lug is catalog-rated 220 for the specified conductor size range, ensuring reliable electrical continuity and mechanical integrity across different conductor materials. Part of ABB’s 162LR series, this connector is optimized for 15 kV systems with a 200 Amp continuous current rating. Its loadbreak interface enables hot-swapping of cables under load, a critical safety and operational feature in power distribution networks. The design meets medium-voltage application demands for reliability, safety, and ease of maintenance. Typical applications include utility substations, industrial power distribution, commercial electrical systems, and renewable energy installations. The 162LR-B-5220 is ideal for environments requiring frequent testing and maintenance access, such as switchgear compartments, pad-mounted transformers, and underground distribution systems. Its robust construction ensures long-term performance in harsh conditions, including moisture, contaminants, and mechanical stress. For proper selection, verify cable insulation diameter and conductor size against ABB catalog tables. The 162LR-B-5220 follows ABB’s catalog number structure, where 'B' denotes the 0.635-0.905 inch insulation diameter range and '5' indicates the standard bi-metal compression lug code. This product is a dependable solution for critical power circuits requiring loadbreak capabilities and testing access.
  • 200 Amp, 15kV rated loadbreak elbow connector for medium-voltage applications
  • Built-in test point enables safe circuit verification without de-energization
  • Accommodates cable insulation diameters from 0.635 to 0.905 inches
  • Bi-metal compression lug for compressed stranded AWG #2 or solid AWG #1 conductors (33.62 mm²)
  • Loadbreak interface allows hot-swapping of cables under load

Specifications

Amperage Rating
200 A
Application
The 162LR is designed for Connecting to and Operating 15kV Class, 200 Amp Distribution apparatus. It Provides a Convenient Method to Connect/Disconnect Cable and Equipment on Power Distribution Systems
Color
Black
Conductor Range
#2 STR/COMPR AWG , #1 SOL/COMPT AWG
Connection Type
Compression Lug
Current Rating
200 A
Environmental Conditions
Products are designed and constructed for all applications including Padmount, Subsurface, Vault, Indoor, Outdoor, Direct Sunlight, Direct Buried and Continuously Submerged in Water
Insulation
True
Material
Bi-Metal Compression Lug
Material
Housing - EPDM-Rubber
Series
162LR-B
Size
Cable Insulation Diameter 0.635 inch to 0.905 inch
Special Features
Fully Shielded, Fully Submersible Molded Rubber Housing, 100 Percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Materials. Provision for Hot Stick Operation. Provision for Ground Wire Connection. Non-Corrosive Capacitive Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector with Test Point
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, #2 Stranded Wire Size. Bi-Metal Compression Lug

162LR-B-5220

15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, #2 Stranded Wire Size. Bi-Metal Compression Lug
6MM2 BLACK CABLE FOR DISTRIBUTION BLOCK ROW TYPE LENGTH 320MM

54211116

6MM2 BLACK CABLE FOR DISTRIBUTION BLOCK ROW TYPE LENGTH 320MM
200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67. 200ECS Jacket Seal Included.

162LR-B-5210-S

200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67. 200ECS Jacket Seal Included.
200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62. 200ECS Jacket Seal Included.

162LR-B-5220-S

200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62. 200ECS Jacket Seal Included.
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, #1 Stranded Wire Size, Bi-Metal Compression Lug

162LR-B-5230

15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, #1 Stranded Wire Size, Bi-Metal Compression Lug
200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62. 200ECS-G3 Jacket Seal and Grounding Kit Included.

162LR-B5220-SG3

200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62. 200ECS-G3 Jacket Seal and Grounding Kit Included.
200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

162LR-B-5230A

200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
15kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .575 inch - .740 Inch Cable Insulation Diameter, #3 Stranded Wire Size, Bi-Metal Compression Lug

162LRJS-A5210

15kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .575 inch - .740 Inch Cable Insulation Diameter, #3 Stranded Wire Size, Bi-Metal Compression Lug

Frequently Asked Questions

What is the maximum operating voltage for this elbow connector?

The ABB 162LR-B-5220 loadbreak elbow connector is rated for 15kV operation.

What conductor sizes can this connector accommodate?

This connector is designed for compressed stranded AWG #2 or solid AWG #1 conductors, with a mm² equivalent of 33.62.

What is the cable insulation diameter range for this connector?

The connector is suitable for cable insulation diameters ranging from 0.635 inches to 0.905 inches.

Does this connector have a test point?

Yes, the ABB 162LR-B-5220 features a built-in test point for circuit testing.

What type of lug is used for conductor connection?

This loadbreak elbow connector utilizes a bi-metal compression lug for secure conductor connection.

How to Install 161LR/162LR Loadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe installation and wiring of 161LR and 162LR Loadbreak Elbow Connectors on various underground distribution cables, ensuring proper connection to a 15kV class loadbreak bushing.

Estimated time: 1h 30m

Tools needed:

Wire strippers/cutters, Wire brush, Crimp tool (refer to lug instructions), Probe wrench, Hotstick, Suitable voltage sensing device (for test point)

Supplies needed:

161LR or 162LR Elbow Connector Housing, Compression Lug, Probe, Lubricant (supplied, do not substitute), Copper wire (No. 14 AWG / 2.5mm or equivalent), Appropriate connector (for neutral wires), Cold shrink tube (if using sealing kit), Conductive copper tape (if using copper tape shield kit), Vinyl tape (if using jacketed cable with drain wires)

  1. Perform Initial Safety Checks and Component Inspection

    DANGER: Ensure all apparatus is de-energized before beginning installation or removal of parts. Do not touch or move energized products. Inspect all package contents to ensure they are complete and undamaged. Verify all components fit properly with the cable and mating products. Check the probe threads by hand-threading into the compression lug; if resistance is encountered, inspect for damage and replace components as needed. Have all required tools ready and maintain cleanliness throughout the procedure.

  2. Prepare the Cable for Connector Installation

    Train the cable to ensure adequate slack for operation. Prepare neutral or drain wires according to your specific cable type (e.g., pull extra length, bind, or remove outer jacket). Cut the cable squarely at the centerline of the bushing. Remove 2-1/8 inches (55mm) of the shield and insulation from the cable end, taking care not to nick the conductor. Wire brush bare aluminum conductors immediately and install the compression lug, rotating to spread inhibitor. Position the lug so the contact threaded hole aligns with the bushing bore. Crimp the lug according to the manufacturer's chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe off excess inhibitor. Remove the insulation shield 6-7/8 inches (175mm) from the cable end, ensuring a straight, smooth, and squared cut. Bevel the insulation end a maximum of 1/8 inch (5mm). Thoroughly clean the insulation to remove all traces of dirt or excess inhibitor.

  3. Assemble the Elbow Connector

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant. DO NOT SUBSTITUTE other lubricants, as they may be harmful. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off all excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the probe wrench until the wrench bends, indicating proper torque.

  4. Ground the Elbow Connector

    Insert one end of a separate copper wire (No. 14 AWG / 2.5mm or equivalent) through the grounding eye on the elbow. Twist the wire tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Ensure adequate slack in the wires to allow for elbow operation. If using a cold shrink grounding kit, refer to its specific instructions.

  5. Connect the Elbow to the Bushing Plug

    DANGER: CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED before proceeding. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Operate the connection using a full insulated hotstick type tool. DO NOT OPERATE BY HAND. Insert the probe tip approximately 2 inches (50mm) into the bushing, then immediately push the elbow home with a fast, firm, straight motion, using sufficient force to engage the internal lock on the elbow connector and bushing interface.

  6. Perform Voltage Test (162LR only)

    If installing a 162LR connector with a test point, you can use it to determine if the circuit is energized. Remove the test point cap with a hotstick, peeling it off at an angle. WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Follow the manufacturer’s directions for your specific sensing device. Treat the elbow as energized until a 'no voltage' indication is confirmed by other means. After testing, clean the inside surface of the cap, lubricate with silicone lubricant, and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.