ABB Installation Products 162LR-B5220-SG3 200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter…
UPC: 075114186483
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 200 Amp, 15kV loadbreak elbow connector
- Features a test point for voltage testing
- Accommodates cable insulation diameter from 0.635 to 0.905 inches (Insulation Letter Code B)
- Bi-metal compression lug for AWG #2 stranded or AWG #1 solid conductors (33.62 mm²)
- Includes 200ECS-G3 jacket seal and grounding kit
Specifications
Amperage Rating | 200 A |
Application | The 162LR is designed for Connecting to and Operating 15kV Class, 200 Amp Distribution apparatus. It Provides a Convenient Method to Connect/Disconnect Cable and Equipment on Power Distribution Systems |
Color | Black |
Conductor Range | #2 STR/COMPR AWG , #1 SOL/COMPT AWG |
Connection Type | LoadBreak Elbow Connector |
Current Rating | 200 A |
Environmental Conditions | Products are designed and constructed for all applications including Padmount, Subsurface, Vault, Indoor, Outdoor, Direct Sunlight, Direct Buried and Continuously Submerged in Water |
Insulation | True |
Material | Bi-Metal Compression Lug |
Material | Housing - EPDM-Rubber |
Series | 162LR |
Size | 0.635 inch to 0.905 inch |
Special Features | Fully Shielded, Fully Submersible Molded Rubber Housing, 100 Percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Materials. Provision for Hot Stick Operation. Provision for Ground Wire Connection. Non-Corrosive Capacitive Test Point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector with Test Point |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

K655LR-F5220
25kV, 600 Amp, Deadbreak Elbow, No Sealing Kit, without Test Point, Cable Insulation .640-.820 inches, Bi-Metal Lug, Conductor Size AWG Compressed/Stranded #2 or Compacted/Solid #1 or mm2 Compact 35.
162LR-B-5230A
200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
162LRJS-A5210
15kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .575 inch - .740 Inch Cable Insulation Diameter, #3 Stranded Wire Size, Bi-Metal Compression Lug
162LR-B-5230-S
200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. 200ECS Jacket Seal Included.
376LR-K5230-SG3
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. 200ECS-G3 Jacket Seal and Grounding Kit Included.
261LRJS-B5240
25/28kV, 200 Amp, Loadbreak Jacket Seal Elbow Connector, .635 inch - .905 inch Cable Insulation Diameter, 1/0 Stranded Wire Size, Bi-Metal Compression Lug.
167ELR-7495-5230S
15kV, 200 Amp, LoadBreak, Repair Elbow Connector/Extended Elbow, Cable Insulation .740-.950 inches, Bi-Metal Compression Lug, Conductor Size #1 Stranded/Compressed or 1/0 Compact/Solid. 200ECS Jacket Seal Included.
167ELR-7495-5230
15kV, 200 Amp, LoadBreak, Repair Elbow Connector/Extended Elbow, Cable Insulation .740-.950 inches, Bi-Metal Compression Lug, Conductor Size #1 Stranded/Compressed or 1/0 Compact/Solid.Frequently Asked Questions
What is the maximum operating voltage for this elbow connector?
The ABB 162LR-B5220-SG3 is rated for 15kV, indicating its maximum operating voltage.
What conductor sizes can be used with this connector?
This connector is designed for compressed stranded AWG #2 or solid AWG #1 conductors, with a mm² size of 33.62.
What is the purpose of the test point on the connector?
The test point allows for safe and convenient voltage testing of the connected circuit.
What is the cable insulation diameter range for this connector?
The connector is designed to fit cable insulation diameters ranging from 0.635 inches to 0.905 inches.
Does this product include a grounding kit?
Yes, the 162LR-B5220-SG3 includes the 200ECS-G3 jacket seal and grounding kit.
How to Install the 162LR Loadbreak Elbow Connector
This guide provides step-by-step instructions for the safe installation and initial setup of the 162LR Loadbreak Elbow Connector, including cable preparation, assembly, grounding, and connection to a bushing.
Estimated time: 1h 30m
Tools needed:
Wire strippers/cutters, Wire brush, Crimp tool, Probe wrench, Hotstick, Vinyl tape
Supplies needed:
162LR Elbow Connector Housing, Compression lug, Probe, Lubricant (supplied, do not substitute), Copper wire (No. 14 AWG / 2.5mm or equivalent), Appropriate connector (for neutral wires), Cold shrink tube (if using sealing kit), Conductive copper tape (if using specific sealing kits)
- Cable Training and Outer Jacket Preparation
Ensure all apparatus is de-energized before starting. Train the cable to ensure adequate slack (24” to 36” or 610-914mm) beyond the bushing centerline for ease of operation. Cut the cable squarely at the centerline of the bushing. Remove the outer jacket to the length specified for your cable type (e.g., 9-5/8” (240mm) for jacketed cables). For concentric neutral cables, unwrap and bind the neutral wires 7-3/4” to 8” (195 to 203mm) back from the bushing center, or prepare to connect them to the tank ground. For copper tape shield cables, remove 7-1/8” (180mm) of the copper tape shield and wrap conductive copper tape over the end to hold it in place. If using a cold shrink sealing kit, slide the cold shrink tube onto the cable, loose end first.
- Conductor and Insulation Preparation
Remove the insulation shield and insulation 2-1/8” (55mm) from the cable end, cutting squarely without nicking the conductor. Wire brush bare aluminum conductors thoroughly and immediately install the compression lug. Rotate the lug to spread the inhibitor and ensure the contact threaded hole aligns with the bushing bore. Crimp the lug according to the manufacturer's chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe off any excess inhibitor. Remove the insulation shield 6-7/8” (175mm) from the cable end, ensuring a straight, smooth, and squared cut. Bevel the insulation end a maximum of 1/8” (5mm). Thoroughly clean the insulation to remove all traces of dirt or excess inhibitor.
- Elbow Assembly
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant. Do not substitute lubricants, as others may be harmful. Maintain cleanliness throughout this process. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off any excess lubricant. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends.
- Grounding
Insert one end of a separate copper wire (No. 14 AWG / 2.5mm or equivalent) through the grounding eye on the elbow. Twist it tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Provide adequate slack in the wires for elbow operation. Note: If using a cold shrink grounding kit, refer to its specific instructions for completion.
- Connect Elbow to Bushing
CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED before proceeding. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Using a full insulated "hotstick" type tool, remove any insulated cap from the bushing. Securely fasten the hotstick to the loadbreak connector pulling eye. Insert the probe tip approximately 2” (50mm) into the bushing. Immediately push the elbow home with a fast, firm, straight motion, applying sufficient force to engage the internal lock on the elbow connector and bushing interface. DO NOT OPERATE BY HAND.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.