ABB Installation Products 162LR-B-5210-S 200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter…
UPC: 075114186391
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 200 Amp, 15kV loadbreak elbow connector for medium-voltage systems
- Bi-metal compression lug for copper-to-aluminum transitions (26.67 mm² / #3 AWG compressed stranded, #2 AWG solid)
- Cable insulation diameter range: 0.635in to 0.905in (code B selection)
- Integrated test point for safe circuit verification without de-energization
- Supplied with 200ECS jacket seal for environmental protection
Specifications
Amperage Rating | 200 A |
Application | The 162LR is designed for Connecting to and Operating 15kV Class, 200 Amp Distribution apparatus. It Provides a Convenient Method to Connect/Disconnect Cable and Equipment on Power Distribution Systems |
Color | Black |
Conductor Range | #3 STR/COMPR AWG , #2 SOL/COMPT AWG |
Environmental Conditions | Products are designed and constructed for all applications including Padmount, Subsurface, Vault, Indoor, Outdoor, Direct Sunlight, Direct Buried and Continuously Submerged in Water |
Insulation | True |
Material | Housing - EPDM-Rubber |
Special Features | Fully Shielded, Fully Submersible Molded Rubber Housing, 100 Percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Materials. Provision for Hot Stick Operation. Provision for Ground Wire Connection. Non-Corrosive Capacitive Test Point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector with Test Point |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

162LR-B-5210
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, #3 Stranded Wire Size, Bi-Metal Compression Lug
162LR-B-5220-S
200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62. 200ECS Jacket Seal Included.
162LR-B-5230
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, #1 Stranded Wire Size, Bi-Metal Compression Lug
162LR-B5220-SG3
200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62. 200ECS-G3 Jacket Seal and Grounding Kit Included.
162LR-B-5230A
200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
162LRJS-A5210
15kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .575 inch - .740 Inch Cable Insulation Diameter, #3 Stranded Wire Size, Bi-Metal Compression Lug
162LR-B-5230-S
200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. 200ECS Jacket Seal Included.
376LR-K5230-SG3
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. 200ECS-G3 Jacket Seal and Grounding Kit Included.Frequently Asked Questions
What material is the pulling eye made of?
The pulling eye is made of robust stainless-steel, promoting durable hotstick control.
What is the purpose of the rigid probe support?
The internal rigid probe support ensures proper switching and easy probe installation.
Does the elbow have an integral jacket seal?
Yes, the enhanced design offers an optional integral jacket seal.
Does the loadbreak elbow have RUS acceptance?
Yes, the enhanced Elastimold 200 amp loadbreak elbow has Rural Utilities Service (RUS) acceptance from the U.S. Department of Agriculture (USDA).
What certifications does the loadbreak elbow have?
The product is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance from the U.S. Department of Agriculture (USDA).
Is the elbow compatible with Elastimold bushings?
Yes, it features a no-stick interface and lifetime ease of operation when used with Elastimold bushings.
What are the voltage ratings for this loadbreak elbow?
The enhanced Elastimold 200 amp loadbreak elbow is designed for 15 kV and 25 kV series applications.
What is the Elastimold 200 amp loadbreak elbow?
It is an enhanced 200 amp loadbreak elbow designed for 15 kV and 25 kV systems, incorporating innovative design and manufacturing experience.
What is the purpose of the rigid probe support?
The internal rigid probe support ensures proper switching and easy probe installation.
What are the voltage ratings for this loadbreak elbow?
The enhanced Elastimold 200 amp loadbreak elbow is designed for 15 kV and 25 kV series applications.
How to Install 161LR and 162LR Loadbreak Elbow Connectors
This guide provides step-by-step instructions for the safe installation and initial setup of 161LR and 162LR Loadbreak Elbow Connectors, designed for terminating UD cables to 15kV class loadbreak bushings.
Estimated time: 1h
Tools needed:
Probe Wrench, Wire brush, Crimp tool, Hotstick, Wire strippers, Voltage sensing device (for capacitive test points)
Supplies needed:
Lubricant (supplied with kit), Copper wire (No. 14 AWG / 2.5mm or equivalent), Appropriate neutral connector
- Verify Components and De-energize Apparatus
DANGER: All apparatus must be de-energized during installation. Inspect all package contents for completeness and damage. Verify all components fit properly with the cable and mating products. Check the probe threads by hand-threading it into the compression lug; if resistance is met, replace damaged components. Have all required tools ready and maintain cleanliness throughout the procedure.
- Train and Prepare Jacketed Concentric Neutral Cable
Train the cable to ensure 24 to 36 inches (610-914mm) of slack beyond the bushing centerline. Place a tape mark at the bushing centerline. Remove 9-5/8 inches (240mm) of the outer jacket from the tape mark. Unwrap the neutral wire back past the bushing centerline. Cut the excess cable squarely at the bushing centerline. If using a 200ECS sealing kit, slide the cold shrink tube onto the cable loose end first.
- Prepare Conductor and Insulation
Remove 2-1/8 inches (55mm) of the shield and insulation from the cable end, ensuring a square cut without nicking the conductor. Wire brush bare aluminum conductors immediately and install the compression lug, rotating it to spread inhibitor. Align the compression lug's threaded hole with the bushing bore. Crimp the lug starting at the crimp line mark, rotating 180 degrees for each successive crimp. Carefully wipe off any excess inhibitor. Remove 6-7/8 inches (175mm) of the insulation shield, ensuring a straight, smooth, and squared cut. Bevel the insulation end by a maximum of 1/8 inch (5mm). Thoroughly clean the insulation to remove all traces of dirt or excess inhibitor.
- Assemble the Elbow Connector
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; do not substitute. Slide the elbow connector onto the cable using a back-and-forth twisting motion, then wipe off all excess lubricant. Align the elbow with the compression lug's threaded hole. Hand-thread the probe into the lug, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends, indicating proper torque.
- Connect Grounding and Neutrals
Insert one end of a separate No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the elbow and twist tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack for elbow operation. If using a cold shrink grounding kit, refer to its specific instructions.
- Connect Elbow to Bushing Plug
DANGER: Confirm that both the transformer and the elbow are de-energized before proceeding. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a hotstick to the loadbreak connector pulling eye. Insert the probe tip approximately 2 inches (50mm) into the bushing, then immediately push the elbow home with a fast, firm, straight motion to engage the internal lock. Do not operate by hand.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.