ABB Installation Products 252LR-B2050 12/20 24kV, 250 Amp, Deadbreak, Elbow Connector with Test Point, No Sealing Kit, Cable…
UPC: 075114373579
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 24 kV rated, 250 amp deadbreak elbow connector for medium-voltage applications
- Copper compression lug for 50 mm² conductors; cable insulation diameter range: 16.13–22.90 mm
- Capacitive test point for safe diagnostic testing without de-energizing the system
- Stainless-steel pulling eye and dual grounding eye positions for enhanced safety
- Meets IEC 60502-4 and CEN 629.1 S2 standards; includes probe, wrench, lubricant, and installation accessories
Specifications
Amperage Rating | 250 A |
Application | 12/20 (24) kV |
Color | Black |
Conductor Range | 50 mm |
Connection | Compression |
Environmental Conditions | Harsh Conditions |
Insulation | True |
Material | Housing - EPDM-Rubber |
Special Features | Robust Stainless Steel Pulling Eye. Dual Grounding Eye Positions. Designed to Remain Fully Operational in Harsh Conditions |
Standard | IEC 60502-4, CEN 629.1 S2 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Elbow Connector with Test Point |
Voltage Rating | 15 to 25 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

252LRJS-B2050
12/20 24kV, 250 Amp, Deadbreak, Elbow Connector with Test Point, with Jacket Seal, Cable Insulation Diameter - .16.13 mm - 22.90 mm, Copper Compression Lug, Conductor Size 50mm. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.
M465LR-P2330
35kV, 630 Amp, Deadbreak Elbow, No Test Point, IEC-IEEE, No Sealing Kit. Cable Insulation Diameter 1.725 to 1.935 inch, Copper Lug, Wire Range 500 kcmil Stranded/Compressed or 600 kcmil Solid Compact or 250/300 mm2. 10.36 inch (264.1mm) x 13 inch (330.2mm) from Bottom to Center of Bushing. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Lubricant, Cable Adapter, Installation Instructions and Crimp Chart.
M465LR-N-2290
35kV, 630 Amp, Deadbreak Elbow, No Test Point, IEC-IEEE, No Sealing Kit. Cable Insulation Diameter 1.515 to 1.780 inch, Copper Lug, Wire Range 300 kcmil Stranded/Compressed or 350 kcmil Solid Compact or 150 mm2. 10.36 inch (264.1mm) x 13 inch (330.2mm) from Bottom to Center of Bushing. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Lubricant, Cable Adapter, Installation Instructions and Crimp Chart.
M465LR-L-2230
35kV, 630 Amp, Deadbreak Elbow, No Test Point, IEC-IEEE, No Sealing Kit. Cable Insulation Diameter 1.180 to 1.465 inch, Copper Lug, Wire Range 1 Stranded/Compressed or 1/0 Solid Compact or 50 mm2. 10.36 inch (264.1mm) x 13 inch (330.2mm) from Bottom to Center of Bushing. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Lubricant, Cable Adapter, Installation Instructions and Crimp Chart.
M465LR-G2250
35kV, 630 Amp, Deadbreak Elbow, with Test Point, IEC-IEEE, No Sealing Kit. Cable Insulation Diameter 0.760 to 0.95 inch, Copper Lug, Wire Range 2/0 Stranded/Compressed or 3/0 Solid Compact or 70 mm2. 10.36 inch (264.1mm) x 13 inch (330.2mm) from Bottom to Center of Bushing. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Lubricant, Cable Adapter, Installation Instructions and Crimp Chart.
K676ELR-L5330-S
25 kV, 900 Amp, Extended Elbow, Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. Cold-Shrinkable Jacket Seal Included.
K656SELR
600 Amp, 15/25kV, 600 Series Spiking Elbow with spiking contact, insulated plug, cap, stud, lug and cable adapter.Frequently Asked Questions
What optional features are available for the connector?
Optional features include sealing and grounding (-S) and a bonding/grounding wire (-G).
What items are included in the connector kit?
Each kit includes the elbow connector housing, copper lug, probe, probe wrench, standard bail assembly, lubricant, installation instructions, crimp chart, and a V.D. cap.
What insulation diameter ranges do cable adapters support?
Cable adapters support insulation diameters from 12.57 mm to 17.40 mm, depending on the specific W code.
What if my cable insulation diameter is below 14.61 mm?
If the insulation outside diameter is lower than 14.61 mm, use the cable adapter 160CA-W.
What type of conductors are compatible with copper lugs?
Copper lugs are suitable for all copper conductors only.
What conductor sizes are compatible with copper lugs?
Copper lugs are compatible with conductor sizes ranging from 25 mm2 to 120 mm2.
What cable insulation diameter ranges are supported?
The connector supports cable insulation diameters ranging from 14.61 mm to 33.27 mm, depending on the W code.
What is the amp rating of the elbow connector?
The elbow connector has a 250 amp deadbreak rating.
What is the voltage rating of this connector?
The Elastimold IEC 250 amp deadbreak elbow connector has a voltage rating of 12/20 (24) kV.
What industry standards does the connector meet?
The connector meets the requirements of IEC 60502-4 and CEN 629.1 S2 standards.
How to Install 252LR Deadbreak Elbow Connectors
This guide provides detailed instructions for the safe and proper installation of 252LR Deadbreak Elbow Connectors on UD jacketed and non-jacketed cables, including cable preparation, assembly, and connection to a deadbreak bushing or accessory device.
Estimated time: 1h 30m
Tools needed:
Wrench, Hot stick, Crimp tool, Wire brush, Cable cutting tool, Wire strippers, Suitable sensing device (for voltage test)
Supplies needed:
252LR Elbow Connector Housing, Compression Lug, Probe, Probe Contact, Lubricant (supplied), Hold-down Bail, No. 14 AWG (2.5mm) Copper Wire, Appropriate connector for neutral wires, Cold shrink tube (if using sealing kit), Conductive copper tape (if using 200ECS-G2 kit), Vinyl tape (if applicable), HV insulated cap(s) or connector(s)
- Perform Initial Checks and Ensure Safety
Read the entire installation instruction before starting. Check package contents for completeness and damage. Verify elbow housing cable entrance and compression lug size for proper cable fit. Check probe threads by hand-threading into the lug. Ensure all apparatus is de-energized during installation or removal. Do not touch or move energized products. This product must be installed only by competent personnel trained in high voltage electrical equipment safety practices.
- Prepare the Cable for Termination
Train the cable to ensure adequate slack. Depending on cable type (non-jacketed, jacketed concentric neutral, jacketed with drain wires, or jacketed copper tape shield), prepare the neutral wires or shield as specified in the documentation, ensuring proper length for grounding. Cut the cable squarely at the centerline of the bushing. If using a sealing kit, slide the cold shrink tube onto the cable.
- Prepare Cable End and Crimp Lug
Remove 2-1/8 inches (55mm) of shield and insulation from the cable end, taking care not to nick the conductor. Wire brush bare aluminum conductors immediately. Place the compression lug over the conductor, rotate to spread inhibitor, and align the contact threaded hole with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe off excess inhibitor. Remove insulation shield 6-7/8 inches (175mm) from the lug, beveling the insulation end 1/8 inch (5mm) max. Thoroughly clean the insulation.
- Assemble the Elbow Housing
Clean the cable insulation and the inside of the elbow housing, then lubricate with the supplied lubricant; do not substitute. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off all excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring not to cross-thread. Tighten the probe with a wrench until the wrench bends.
- Connect Concentric Neutral Wires
Place the hold-down bail in the hold-down bracket. Using a separate No. 14 AWG (2.5mm) copper wire or equivalent, insert one end through the grounding eye on the elbow and twist tightly. Twist all neutral wires together and connect them to ground using an appropriate connector. Ensure adequate slack in the wires for elbow operation.
- Connect Elbow to Bushing Plug
Clean the receptacle portion of the elbow connector and the mating bushing, then lubricate with the supplied lubricant. Lubricate only if the transformer and elbow are known to be de-energized. Use a fully insulated hot stick to place the elbow onto the bushing. Do not operate by hand. Do not separate if energized.
- Secure the Elbow with the Bail
Pull the hold-down bail up over the crown or top of the elbow so that the eyebolt on the bail is directly over the operating eye. Tighten down on the elbow locator by turning the eyebolt in a clockwise direction. Adjust the nut on the eyebolt until it allows the eyebolt to seat securely in the locator. The nut should act as a stop to prevent excessive force on the elbow.
- Perform Voltage Test (Optional Verification)
If equipped with a capacitance test point, remove the test point cap with a hotstick, peeling it off at an angle. Use a suitable sensing device, made for use with capacitive test points, to determine if the cable is energized. Do not use conventional voltage measuring equipment. Treat the elbow as energized until the 'no voltage' indication is confirmed by other means. After testing, clean the cap, lubricate, and replace it on the test point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.