ABB Installation Products 15PCJ2J1330 15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable…
UPC: 075114239653
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Universal housing accommodates cable insulation diameters from 0.980" to 1.180"
- Designed for stranded aluminum conductors up to 500 kcmil
- Meets IEEE Standard 404 for 15kV voltage class with 110kV BIL impulse withstand
- Fully shielded, fully submersible, and rated for direct burial or vault installations
- Withstands pulls up to 500 lbs and short-time current ratings up to 35kA
Specifications
Application | For Direct Burial, Vault, Submersible and Other Severe Service Applications |
Color | Black |
Conductor Range | 500 kcmil |
Connection | Compression |
Insulation | Yes |
Material | EPDM Rubber |
Number Of Conductors | 2 |
Size | 16-3/8 inch long |
Special Features | Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable |
Standard | IEEE Standard 404 |
Type | Power Cable Joint |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

15PCJ1J2330-S
15kV, Power Cable Joint Splice with Sealing Kit, Single Piece Housing, Cable Insulation Diameter J - .980 -1.050 inches. Copper Conductor, Conductor Size - 500 Stranded/Compressed. Includes Cold Shrinkable Jacket Seal.
15PCJ2F1200
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #4/Solid #3.
69TCJS45147P55MDANB
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 5, Connector type Aluminum. Connector Code 47P - Conductor Diameter Range - 1.378-1.425 inch (35.00-36.19mm), Heatsink Size 55 - Outside Diameter 3.000 inch, Heatsink Bore - M - 1.468 inch. Type Shield - D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit - A - 4/0 Bonding Cable 6 foot quantity 1 with Split Bolts quantity 4, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink standard package
69TCJS1R246PNBHNN
69kV, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size R - Bore Diameter 1.930 inch, Insulation Range 2.200-2.580 inch, Connector Type - Copper, Conductor Code 46P - 1.328-1.377 inch Diameter, Heatsink Size and Bore not Required, Type Shield B - Copper 1/3 Neutral Wire, Metallic Screen Continuity Kit H - 4/0 Bonding Cable 4 foot long Quantity 2 without Split Bolts, Armour Kit Not Required, Outer Jacket Restoration Kit Not Required.
15PCJ2F1220
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.
15PCJ2F1250
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.
15PCJ2G1220
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.
15PCJ1G2210
15kV, Power Cable Joint, Single Piece Housing, Cable Insulation .760-.950 inches, Copper Compression Lug, Conductor Size #2 Compact/Solid.Frequently Asked Questions
Can copper connectors be used with aluminum conductors?
No, copper compression connectors are suitable for splicing copper-to-copper conductors only and should not be used on aluminum conductors.
What is the short-time current rating for PCJ joints?
The short-time current rating for PCJ power cable joints is equal to that of the cable rating, up to 35 kA.
What is the continuous current rating of PCJ joints?
The continuous current rating of PCJ power cable joints is equal to that of the cable rating.
What safety standards do PCJ power cable joints meet?
The shield design meets IEEE 592 standard, and the connectors meet ANSI 119.4 Class A and Class 3 ratings.
What are the two styles of PCJ power cable joints?
Style 1 is for straight splicing of two similar cables. Style 2 includes separate cable adapters for transition splicing between two different cable sizes.
What conductor materials and sizes are compatible with PCJ joints?
PCJ power cable joints are compatible with copper or aluminum conductors, supporting a wide range of sizes up to 1250 kcmil.
What voltage classes are PCJ power cable joints available in?
Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.
Where can Elastimold PCJ power cable joints be installed?
They can be installed in direct-burial, underground vault, and overhead applications, providing a permanent, fully shielded, and fully submersible splice.
What types of cable splicing do PCJ joints support?
PCJ power cable joints support straight splicing of two similar cables or transition splicing of different cable sizes up to 1250 kcmil.
Where can Elastimold PCJ power cable joints be installed?
They can be installed in direct-burial, underground vault, and overhead applications, providing a permanent, fully shielded, and fully submersible splice.
How to Install the 15PCJ2J1330 Straight Joint
This guide provides step-by-step instructions for the safe and proper installation of the 15PCJ2J1330 permanent, fully shielded, fully submersible straight joint for aluminum and/or copper conductor cables.
Estimated time: 2h
Tools needed:
Wire strippers, Circular cutting tool, Glass scraper, Hex wrench, Wirebrush, Crimping tool
Supplies needed:
Joint Housing, Splice (Conductor Contact), Cable Adapters, Lubricant, Retaining Collars, Hose Clamp, Tape, User-supplied connector (for grounding), #14 AWG copper wire (if shield wires are smaller), Heat/cold shrink tubing (for jacket reconstruction), Bonding cable(s) (if needed), Insulating and sealing tapes (if needed), Solder (if needed), CNW’s connectors (if needed)
- De-energize Apparatus and Ensure Safety
DANGER: De-energize all apparatus during installation or removal of parts. Ensure all work is performed by competent personnel trained in good safety practices involving high voltage electrical equipment. Do not touch or move energized products in the work area. Failure to follow these instructions will result in damage to the product and serious or fatal injury.
- Prepare Cable 1 Jacket
Using the stripping guide, carefully remove 11-1/4 inches (285.7mm) of the cable jacket from Cable 1. Fold back the shield wires and tape their ends to the jacket, allowing enough extra length to rejoin over the joint later.
- Clean Cable 1 and Slide Housing
Clean the surface of the insulation shield, shield wires, and jacket of Cable 1 for a distance of 30 inches (760mm). Slide the joint housing onto Cable 1 to a distance of 30 inches (760mm).
- Remove Insulation Shield and Cable Insulation
Using the stripping guide, carefully remove the insulation shield and cable insulation from both Cable 1 and Cable 2. DO NOT CUT OR NICK THE INSULATION, as this could result in failure of the assembly.
- Mark Insulation
Wrap two turns of tape 1 inch (25mm) from the edge of the insulation shield on both cables to serve as a marker.
- Lubricate Cable Insulation
Clean the cable insulation on both cables. Then, lubricate the insulation to provide a build-up or ramp of lubricant at the edge of the insulation shield.
- Lubricate Cable Adapters
Take one cable adapter and thoroughly lubricate the inside of both ends.
- Install Cable Adapter on Cable 1
Install the lubricated cable adapter onto Cable 1 until it meets the tape marker as shown in the documentation.
- Install Cable Adapter on Cable 2
Repeat the lubrication and installation process for the second cable adapter on Cable 2, ensuring it also meets its respective tape marker.
- Prepare Retaining Collars
Select the appropriate retaining collar for Cable 1 and partially thread the correct size setscrews into it (refer to instructions packaged with the collars).
- Install Retaining Collar on Cable 1
Position the retaining collar over the insulation of Cable 1, flush against the cable adapter. Using the supplied hex wrench, tighten each set screw only one or two turns at a time to keep the collar centered over the insulation. Continue tightening the setscrews until they are below the surface of the collar.
- Install Retaining Collar on Cable 2
Repeat the process for Cable 2, installing the second retaining collar in the same manner.
- Clean and Secure Cable Adapters
Thoroughly clean the ends of both cable adapters and the adjacent cable areas. Install a hose clamp around the adapter on the side opposite the splice from where the housing is stored, as shown in the documentation, to hold the adapter in place. Tape over the hose clamp to create a smooth surface.
- Insert Conductors into Splice
Wirebrush the exposed conductors of both cables. Immediately insert the prepared conductors into the splice. Verify that the 'Check' dimension (distance between cable adapters) does not exceed 8-1/2 inches (215mm); if it does, redo the assembly.
- Crimp Splice
Crimp the splice following the recommendations provided with the splice component.
- Verify Splice and Lubricate
Wipe off all excess inhibitor. Check the distance between the cable adapters again; if it exceeds 8-3/4 inches (222mm), redo the assembly. Clean and lubricate the outside surface of both cable adapters.
- Position Housing
Slide the joint housing into its final position, ensuring it is centered over the cable adapters.
- Remove Tape and Verify Coverage
Remove all temporary tape. Confirm that no cable or adapter insulation is exposed after the joint housing is positioned.
- Secure Shield Wires
Reshape the shield wires and secure them to the ends of the joint as shown in the documentation.
- Ground Joint
Insert one of the shield wires from Cable 1 (if #14 AWG or larger) through the joint grounding eye. Repeat this for Cable 2. If shield wires are smaller than #14 AWG, use a separate #14 AWG copper wire or equivalent for grounding.
- Connect Grounding Wires
Connect the joint grounding wires and any remaining shield wires using an appropriate user-supplied connector.
- Reconstruct Cable Jacket
Reconstruct the cable jacket (where applicable) over both cables and also over the joint housing. Note that heat/cold shrink materials for this step are not included in the kit.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.