Authorized ABB Distributor (Installation Products)
ABB - Installation Products 15PCJ2F1240 - 15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

ABB Installation Products 15PCJ2F1240 15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable…

UPC: 075114238861


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This ABB 15kV Power Cable Joint, SKU 15PCJ2F1240, is engineered for reliable electrical connections in medium-voltage applications. It features a Style 2 joint design with a universal housing, simplifying installation across various cable configurations. The kit includes separate cable adapters, ensuring a precise fit for aluminum conductors. Designed for stranded AWG 1/0 or solid AWG 2/0 conductors, this joint accommodates cable insulation diameters ranging from 0.640 inches to 0.820 inches. The universal housing provides a secure and insulated termination point, critical for maintaining system integrity and preventing electrical faults. Its construction is optimized for straightforward field application, reducing installation time and potential for error. This product is suitable for power distribution networks, industrial facilities, and other infrastructure requiring robust and dependable cable jointing solutions. The separate adapters allow for flexibility in accommodating specific cable dimensions within the specified range, ensuring a tight seal and optimal electrical performance. ABB's commitment to quality in their Installation Products ensures that this joint meets the functional requirements for safe and efficient power transmission. UNSPSC Code: 39121452.
  • 15kV Power Cable Joint, Style 2
  • Universal Housing for versatile application
  • Separate Cable Adapters included
  • Accommodates 0.640" to 0.820" Cable Insulation Diameter
  • Suitable for AWG 1/0 Stranded / 2/0 Solid Aluminum Conductors

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
1/0 STR AWG , 2/0 SOL AWG
Connection
Compression
Insulation
Yes
Material
EPDM Rubber
Number Of Conductors
2
Size
16-3/8 inch long
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

15PCJ1F2240

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size Stranded 500.

15PCJ2J1330

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size Stranded 500.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #4/Solid #3.

15PCJ2F1200

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #4/Solid #3.
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 5, Connector type Aluminum. Connector Code 47P - Conductor Diameter Range - 1.378-1.425 inch (35.00-36.19mm), Heatsink Size 55 - Outside Diameter 3.000 inch, Heatsink Bore - M - 1.468 inch. Type Shield - D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit - A - 4/0 Bonding Cable 6 foot quantity 1 with Split Bolts quantity 4, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink standard package

69TCJS45147P55MDANB

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 5, Connector type Aluminum. Connector Code 47P - Conductor Diameter Range - 1.378-1.425 inch (35.00-36.19mm), Heatsink Size 55 - Outside Diameter 3.000 inch, Heatsink Bore - M - 1.468 inch. Type Shield - D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit - A - 4/0 Bonding Cable 6 foot quantity 1 with Split Bolts quantity 4, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink standard package
69kV, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size R - Bore Diameter 1.930 inch, Insulation Range 2.200-2.580 inch, Connector Type - Copper, Conductor Code 46P - 1.328-1.377 inch Diameter, Heatsink Size and Bore not Required, Type Shield B - Copper 1/3 Neutral Wire, Metallic Screen Continuity Kit H - 4/0 Bonding Cable 4 foot long Quantity 2 without Split Bolts, Armour Kit Not Required, Outer Jacket Restoration Kit Not Required.

69TCJS1R246PNBHNN

69kV, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size R - Bore Diameter 1.930 inch, Insulation Range 2.200-2.580 inch, Connector Type - Copper, Conductor Code 46P - 1.328-1.377 inch Diameter, Heatsink Size and Bore not Required, Type Shield B - Copper 1/3 Neutral Wire, Metallic Screen Continuity Kit H - 4/0 Bonding Cable 4 foot long Quantity 2 without Split Bolts, Armour Kit Not Required, Outer Jacket Restoration Kit Not Required.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.

15PCJ2F1220

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.

15PCJ2F1250

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.

15PCJ2G1220

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.

Frequently Asked Questions

What type of connector is included for aluminum conductors?

Kits for aluminum conductors include an aluminum compression connector suitable for splicing aluminum to aluminum or aluminum to copper conductors.

What are Elastimold PCJ power cable joints used for?

They are used for straight splicing of two similar cables or transition splicing of different cable sizes, up to 1250 kcmil, in new or existing installations.

Where can PCJ power cable joints be installed?

These joints provide a permanent, fully shielded, fully submersible splice suitable for direct-burial, underground vault, and overhead applications.

What are the two styles of PCJ power cable joints?

Style 1 has a single-piece housing for straight splicing of similar cables. Style 2 uses separate cable adapters for transition splicing between different cable sizes.

What voltage classes are available for PCJ joints?

Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

What types of conductors are compatible with PCJ joints?

PCJ power cable joints can be used with copper or aluminum conductors, supporting a wide range of sizes up to 1250 kcmil.

What cable types are compatible with PCJ power cable joints?

They are designed for UD cable with concentric neutral and extruded insulation shielding. They also work with fabric-tape shielded or lead-jacketed cables using proper adapters.

What is the pull force rating for PCJ joints?

The pin-and-socket interlock design of the PCJ power cable joints can withstand a pull force of up to 500 lb.

What safety standards do PCJ joints meet?

The shield design meets IEEE 592 standard, and the connectors meet ANSI 119.4 Class A and Class 3 ratings.

How is grounding achieved with PCJ power cable joints?

A grounding eye provides a convenient point to connect a ground wire to the molded conductive shield, placing it at ground potential.

How to Install a 15/25/35PCJ2WXXXX-RC Straight Joint

This guide provides step-by-step instructions for installing the 15/25/35PCJ2WXXXX-RC straight joint, covering cable preparation, adapter installation, splicing, and final assembly for shielded cables.

Estimated time: 2h

Tools needed:

Stripping guide, Circular cutting tool or glass scraper, Hex wrench, Wirebrush, Crimping tool

Supplies needed:

Joint Housing, Splice (Conductor Contact), Cable Adapters, Lubricant, Retaining Collars (2), Hose Clamp, Electrical tape, Appropriate connector (for grounding/shield wires), #14 AWG copper wire or equivalent (if needed), Heat/cold shrink (for cable jacket reconstruction)

  1. Perform Pre-Installation Safety and Inspection

    DANGER: Ensure all apparatus is de-energized before starting. Inspect all parts for damage, proper rating, and compatibility with mating parts. Read the entire installation instructions. Have all required tools at hand and maintain cleanliness. Examine mating cable ends to ensure they are free from moisture and contaminants. Remove graphite coatings 12 inches (30.5cm) beyond the cable jacket cut using a circular cutting tool or by scraping with glass; avoid sanding. If strand-filled or water-blocking material is present in conductors, contact the cable manufacturer for welding/crimping procedures.

  2. Prepare Cable 1 and Install Housing

    Use the stripping guide to carefully remove the cable jacket of both cables for a distance of 11-1/4 inches (285.7mm). Fold back shield wires and tape the end of the wires on Cable 1 to the jacket, allowing enough extra length to rejoin later. Clean the surface of the insulation shield, shield wires, and jacket for a distance of 30 inches (760mm). Slide the joint housing onto Cable 1 to a distance of 30 inches (760mm).

  3. Prepare Both Cables for Splicing

    Using the stripping guide, carefully remove the insulation shield and cable insulation. DO NOT CUT OR NICK THE INSULATION, as this could result in assembly failure. Wrap two turns of tape 1 inch (25mm) from the edge of the insulation shield as a marker on both cables. Clean the cable insulation, then lubricate it to provide a build-up or ramp of lubricant at the edge of the insulation shield.

  4. Install Cable Adapters

    Take one cable adapter and lubricate the inside of both ends. Install the cable adapter onto the cable until it meets the tape marker as shown in the diagram. Repeat this process for the other cable adapter on the second cable.

  5. Install Retaining Collars

    Select a retaining collar and partially thread the proper size setscrews (refer to instructions packaged with the collars). Position the retaining collar over the insulation and flush against the cable adapter. Using the supplied hex wrench, tighten each set screw only one or two turns at a time to keep the collar centered over the insulation. Continue to tighten the set screws until they are below the surface of the collar. Repeat this process for Cable 2.

  6. Prepare for Splice and Install Hose Clamp

    Thoroughly clean the end of the cable adapters and the cable where indicated. Install a hose clamp around the adapter on the opposite side of the splice from where the housing is stored, to hold the adapter in place during final assembly. Tape over the hose clamp to form a smooth surface.

  7. Splice Conductors

    Wirebrush the exposed conductors of both cables and immediately insert them into the splice. Ensure the 'Check' dimension does not exceed 8-1/2 inches (215mm); if it does, redo the assembly. Crimp the splice following the recommendations provided with it. Wipe off all excess inhibitor, then check the distance between the cable adapters. If it exceeds 8-3/4 inches (222mm), redo the assembly.

  8. Final Housing Positioning and Shield Wire Connection

    Clean and lubricate the outside surface of the cable adapters before sliding the housing into its final position. Slide the housing into its final position, centering it over the cable adapters. Remove all tape; cable and adapter insulation must not be exposed after positioning the joint. Reshape the shield wires and secure them to the ends of the joint. Insert one of the shield wires from Cable 1 (if #14 AWG or larger) through the joint grounding eye; repeat for Cable 2. If shield wires are smaller than #14 AWG, use separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and remaining shield wires using an appropriate connector.

  9. Reconstruct Cable Jacket

    Reconstruct the cable jacket (where applicable) over both cables and also over the joint housing. This typically involves using heat or cold shrink materials, which are not included in the kit.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.