Panduit FLEX1U12 - The HD Flex Fiber Enclosure is 1 RU and is configured with sliding front-access drawers to accept up to six 12-port HD Flex cassettes or Fiber Adapter Panels for a maximum density of 144 fibers.
Panduit

FLEX1U12

UPC: 613056142978


Documents & Media
BrochureTechnical DrawingFull Engineering DrawingInstallation InstructionsSpecification SheetVideo Clip

Contact for Pricing

Overview

The Panduit HD Flex Fiber Enclosure (SKU: FLEX1U12) is a 1 RU solution engineered for high-density fiber optic applications. This enclosure is designed to accommodate up to six 12-port HD Flex cassettes or Fiber Adapter Panels, providing a maximum density of 144 fibers. Its key feature is the sliding front-access drawers, which facilitate easy installation, management, and maintenance of fiber connections. The enclosure supports various modular cassettes, including MTP/MPO-LC pre-terminated cassettes that offer 24 fibers each. These cassettes are available for OS2, OM3, OM4, and OM5 fiber types and support MTP-24, MTP-12, and MTP-8 configurations. The HD Flex enclosure is purpose-built for demanding environments such as data centers, SANs, medical healthcare facilities, and central offices where high performance, density, and rapid deployment are critical. It is designed to support migration to 10G/40G/100G/200G/400G systems. An integrated front cable management tray within the enclosure ensures organized patch cord management, with a dedicated tray for each cassette to maintain separation and prevent tangles. The spring cotter mechanism allows for simple insertion and secure locking of cassettes. Manufactured in the US, this enclosure is built for reliability and efficiency in modern network infrastructure.
  • 1 RU high-density fiber enclosure
  • Accommodates up to six 12-port HD Flex cassettes or Fiber Adapter Panels
  • Maximum fiber capacity of 144 fibers
  • Sliding front-access drawers for easy management
  • Supports MTP/MPO-LC cassettes for OS2, OM3, OM4, OM5 fiber

Specifications

Application
Fiber Optic Cable Management
Color
Black
Depth
15.11 in
Depth
383.794 mm
Mounting
1RU
Rack Spaces*
1
Standard
RoHS Compliant
Type
Fiber Enclosure
Width
19.69 in
Width
500.126 mm
Package Dimensions (L x W x H)
23.75 IN x 20 IN x 3.875 IN
Package Weight (Imperial)
14.5 lbs
Power supply for DIN-rail

PS-60

Power supply for DIN-rail
Super-Safeway® Multiple Outlet Box, Extended Depth, 2-Sided, F2 (1/2") Cord Grip Body, with Flip Lids for (2) Duplex Not Included

3085

Super-Safeway® Multiple Outlet Box, Extended Depth, 2-Sided, F2 (1/2") Cord Grip Body, with Flip Lids for (2) Duplex Not Included
Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .

ST4803PDGM

Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .
Ethernet SHDSL Extender

DDW-120

Ethernet SHDSL Extender
6U PERF PANEL

PPFS19010BK

6U PERF PANEL
Fiber cable ODC to SC duplex - 670mm

Fiber cable ODC SC Duplex 670mm

Fiber cable ODC to SC duplex - 670mm
DIN Rail ? DIN 35

ARH 1656

DIN Rail ? DIN 35
Cable Manager, fits 19-inch open rack, Black, Steel

ECK19H

Cable Manager, fits 19-inch open rack, Black, Steel
DataCom Enclosure Pkg, Bulletin DPVD (PROLINE® Voice and Data Package - PROLINE Voice and Data Package), Size/Dims: 2000x700x800mm, Material: Steel, Finish: Lt Gray

PDCP2078

DataCom Enclosure Pkg, Bulletin DPVD (PROLINE® Voice and Data Package - PROLINE Voice and Data Package), Size/Dims: 2000x700x800mm, Material: Steel, Finish: Lt Gray
This TX6A 10Gig Cat 6A STP Patch Cord is a 12-Meter, Int'l Grey cord constructed of 26 AWG, shielded, twisted pair, stranded, CM/LSZH cable and with high-performance modular plugs. Its tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. The slender strain relief boot provides easy access in high-density applications. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.

STP6X12MIG

This TX6A 10Gig Cat 6A STP Patch Cord is a 12-Meter, Int'l Grey cord constructed of 26 AWG, shielded, twisted pair, stranded, CM/LSZH cable and with high-performance modular plugs. Its tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. The slender strain relief boot provides easy access in high-density applications. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.
OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std IL

F62ERLNSNSNM002

OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std IL
Membrane plate cable entry system offers a good strain relief while maintaining IP/NEMA ingress sealing rating. The CESUM3-C15 is a Rectangular Un-Terminated Cable Entry System, 4.1" (103 mm) Long, with 8 Openings 0.12" (3.0 mm) to 0.31" (8 mm), 3 Openings 0.20" (5.1 mm) to 0.35" (9.0 mm), 4 Openings 0.3" (7.5 mm) to 0.47" (12.0 mm). Color is Black. Standard Package Quantity is 1 PC.

CESUM3-C15

Membrane plate cable entry system offers a good strain relief while maintaining IP/NEMA ingress sealing rating. The CESUM3-C15 is a Rectangular Un-Terminated Cable Entry System, 4.1" (103 mm) Long, with 8 Openings 0.12" (3.0 mm) to 0.31" (8 mm), 3 Openings 0.20" (5.1 mm) to 0.35" (9.0 mm), 4 Openings 0.3" (7.5 mm) to 0.47" (12.0 mm). Color is Black. Standard Package Quantity is 1 PC.

Frequently Asked Questions

What is the maximum fiber capacity per rack unit?

The HD Flex™ Fiber Cabling System supports up to 144 fibers per rack unit.

How does the split-tray design benefit serviceability?

The split-tray design allows servicing of cassettes without disturbing adjacent connections, minimizing circuit disruptions.

What types of fiber trunks are available?

Pre-terminated PanMPO™ Trunk Cable Assemblies are available in multimode or singlemode, with 12-fiber, 24-fiber, and 48-fiber options.

What is the installation requirement for the HD Flex™ system?

The HD Flex™ Fiber Cabling System can be installed by a single technician, simplifying deployment.

What is the purpose of the MPO parking feature?

The MPO parking feature reduces installation time for fiber trunks during cable plant migrations.

What is the maximum fiber capacity of the HD Fusion Fiber Splicing Enclosure?

The HD Fusion Fiber Splicing Enclosure can accommodate up to 576 single fibers and up to 864 ribbon fibers.

How many ports do the cassettes support?

Cassettes are available in either 6-port or 12-port configurations.

What is the design feature for cable management?

The system features side trunk cable management for easy access to cables and connectors.

What types of patch cords are available?

Patch cords are available with Push-Pull LC Duplex or PanMPO Interconnects in various configurations.

What configurations can the enclosures support?

Enclosures can be reconfigured to accept either 6-port or 12-port cassettes and adapter panels.

How to Install the FLEX1U12 Fiber Cassette Enclosure

This guide provides step-by-step instructions for installing the FLEX1U12 Fiber Cassette Enclosure onto a rack, including mounting, wiring, and initial setup.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Tak-Tys, Fiber caution label, Laser warning label

  1. Mount the enclosure

    Secure the FLEX1U12 enclosure to the rack by pre-installing two screws in the bottom hole location of the desired rack unit. Then, place the enclosure onto the screws and install a minimum of four additional screws to secure it firmly.

  2. Install the trunk slack plate

    Attach the trunk slack plate to the rear of the enclosure by engaging the pins into the slots and tilting it down into place. Tighten the captive screws to secure the plate.

  3. Connect the trunk cables

    Route the trunk cables to the rear of the installed cassettes. Ensure to create a slack loop for all incoming cables, allowing for movement of the trays. Use Tak-Tys to secure the cables to the slack plate.

  4. Install the cassettes

    Insert the cassettes into the enclosure starting from the bottom-most slot on the right. Push each cassette forward until it clicks into place, populating from right to left.

  5. Label the enclosure

    Apply the fiber caution and laser warning labels to the enclosure as per the provided instructions to ensure safety compliance.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.