Contact for Pricing
Overview
- 4 RU height for high-density fiber deployments
- Modular design accepts up to 24 HD Flex Fiber Cassettes or Fiber Adapter Panels
- Maximum density of 576 fibers
- Supports 10G/40G/100G/200G/400G system migration
- Inbuilt front cable management tray for organized patching
Specifications
Application | Fiber Optic Cable Management |
Color | Black |
Depth | 15.11 in |
Depth | 383.794 mm |
Material | Plastic;Steel |
Mounting | 4RU |
Mounting Type | Rack-Mount |
Rack Spaces* | 4 |
Series | HD Flex |
Size | 4 RU |
Standard | RoHS Compliant |
Type | Fiber Enclosure |
Width | 19.69 in |
Width | 500.126 mm |
Package Dimensions (L x W x H) | 23.75 IN x 20 IN x 10 IN |
Package Weight (Imperial) | 35.8 lbs |

ST4803PDGM
Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .
3085
Super-Safeway® Multiple Outlet Box, Extended Depth, 2-Sided, F2 (1/2") Cord Grip Body, with Flip Lids for (2) Duplex Not Included
PDCP2078
DataCom Enclosure Pkg, Bulletin DPVD (PROLINE® Voice and Data Package - PROLINE Voice and Data Package), Size/Dims: 2000x700x800mm, Material: Steel, Finish: Lt Gray
STP6X12MIG
This TX6A 10Gig Cat 6A STP Patch Cord is a 12-Meter, Int'l Grey cord constructed of 26 AWG, shielded, twisted pair, stranded, CM/LSZH cable and with high-performance modular plugs. Its tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. The slender strain relief boot provides easy access in high-density applications. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.
F62ERLNSNSNM002
OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std IL
CESUM3-C15
Membrane plate cable entry system offers a good strain relief while maintaining IP/NEMA ingress sealing rating. The CESUM3-C15 is a Rectangular Un-Terminated Cable Entry System, 4.1" (103 mm) Long, with 8 Openings 0.12" (3.0 mm) to 0.31" (8 mm), 3 Openings 0.20" (5.1 mm) to 0.35" (9.0 mm), 4 Openings 0.3" (7.5 mm) to 0.47" (12.0 mm). Color is Black. Standard Package Quantity is 1 PC.Frequently Asked Questions
What is the maximum fiber capacity per rack unit?
The HD Flex™ Fiber Cabling System supports up to 144 fibers per rack unit.
How does the split-tray design benefit serviceability?
The split-tray design allows servicing of cassettes without disturbing adjacent connections, minimizing circuit disruptions.
What types of fiber trunks are available?
Pre-terminated PanMPO™ Trunk Cable Assemblies are available in multimode or singlemode, with 12-fiber, 24-fiber, and 48-fiber options.
What is the installation requirement for the HD Flex™ system?
The HD Flex™ Fiber Cabling System can be installed by a single technician, simplifying deployment.
What is the purpose of the MPO parking feature?
The MPO parking feature reduces installation time for fiber trunks during cable plant migrations.
What is the maximum fiber capacity of the HD Fusion Fiber Splicing Enclosure?
The HD Fusion Fiber Splicing Enclosure can accommodate up to 576 single fibers and up to 864 ribbon fibers.
How many ports do the cassettes support?
Cassettes are available in either 6-port or 12-port configurations.
What is the design feature for cable management?
The system features side trunk cable management for easy access to cables and connectors.
What types of patch cords are available?
Patch cords are available with Push-Pull LC Duplex or PanMPO Interconnects in various configurations.
What configurations can the enclosures support?
Enclosures can be reconfigured to accept either 6-port or 12-port cassettes and adapter panels.
How to Install the FLEX4U12 Fiber Cassette Enclosure
This guide provides step-by-step instructions for installing and configuring the FLEX4U12 Fiber Cassette Enclosure on a DIN rail.
Estimated time: 1h
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors, Tak-Tys, Fiber caution label, Laser warning label
- Mount the enclosure
Position the FLEX4U12 enclosure onto the rack. Pre-install two screws in the top hole location of the bottom most RU in the desired rack position. Secure the enclosure with a minimum of four screws.
- Install the trunk slack plate
Engage the pins on the trunk slack plate into the slots on the enclosure and tilt down into place. Tighten the captive screws to secure the plate.
- Connect trunk cabling
Attach the trunk cabling to the rear port of the cassette. Ensure the polarity label on the cassette is oriented correctly. Insert the cassette into the slot and push forward until it clicks into place.
- Install patch cords
Open the enclosure door and pull the tray out to the service position. Install patch cords into the front of the cassettes from left to right, starting with the bottom most row.
- Calibrate and test
Verify that all trays move freely after routing cables. Adjust if necessary. Use a multimeter to check connections and ensure proper functionality.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.