Panduit E48E20LTAA - TAA EL2P MS PDU, 30/32 AMP, (24)C13/C15, (24)C13/C15/C19/C21, IEC 60309 3P+N+E 6h 30A/32A (IP44)-3M, BLACK
Panduit

E48E20LTAA

UPC: 613056916135


Documents & Media
BrochureTechnical BulletinTechnical DrawingFull Engineering DrawingInstallation InstructionsSpecification SheetUser ManualOwners Manual

Contact for Pricing

Overview

The Panduit E48E20LTAA is a TAA-compliant, Enterprise Level 2 (EL2P) Metered (MS) Power Distribution Unit (PDU) designed for robust power management in data centers and enterprise environments. This PDU supports a 30/32 Amp current rating and features a comprehensive outlet configuration to accommodate a variety of IT equipment. It includes (24) C13/C15 outlets and an additional (24) C13/C15/C19/C21 outlets, providing flexibility for both standard and high-power devices. Power is supplied via an IEC 60309 3-Phase + Neutral + Earth (3P+N+E) 6-hour connector, rated at 30A/32A, ensuring a secure and reliable power input. The PDU is housed in a black chassis and is rated IP44, offering protection against solid objects larger than 1mm and water splashes. It comes with a 3-meter power cord for flexible installation. Manufactured by Panduit, this PDU (SKU: E48E20LTAA) is suitable for applications requiring TAA compliance. Its extensive outlet count and robust input connector make it ideal for densely populated racks where efficient power distribution and monitoring are essential. The meter functionality allows for real-time power consumption tracking, aiding in capacity planning and energy efficiency initiatives. This unit is built to support critical IT infrastructure, ensuring reliable power delivery to servers, network switches, and storage devices.
  • TAA Compliant Enterprise Level 2 (EL2P) Metered PDU
  • 30/32 Amp current rating
  • Total of 48 outlets: (24) C13/C15 and (24) C13/C15/C19/C21
  • IEC 60309 3P+N+E 6h 30A/32A input connector
  • IP44 rated for splash protection, 3-meter cord

Specifications

Color
Black
Current Rating
30/32 A
Frequency Rating, Maximum
240 V
Frequency Rating, Minimum
240 V
Ip Rating
IP44
Material
Metal
Mounting
Vertical
Phase
3
Poles
3P+N+E
Series
TAA EL2P MS PDU
Standard
UL 62368-1, CAN CSA-C22.2 No. 62368-1 EMC: FCC 47 CFR Part 15, Class A, Subpart B. ICES-003 Issue 7
Type
PDU
Width
2 in
Width
50.8 mm
Package Dimensions (L x W x H)
70.08 IN x 3 IN x 3 IN
Package Dimensions (L x W x H)
178.0032 cm x 7.62 cm x 7.62 cm
Package Weight (Imperial)
22.4900 L
Package Weight (Metric)
10.2015 kg
Power supply for DIN-rail

PS-60

Power supply for DIN-rail
The TX6A™ 10Gig Cat 6A UTP Patch Cord is a 1-Meter, Blue cord constructed of 24 AWG, unshielded, twisted pair stranded, LSZH (60332-1) cable with high-performance modular plugs. Its MaTriX Tape Technology limits alien crosstalk, ensuring 10 Gb/s transmission. The tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.

UTP6AL1MBU

The TX6A™ 10Gig Cat 6A UTP Patch Cord is a 1-Meter, Blue cord constructed of 24 AWG, unshielded, twisted pair stranded, LSZH (60332-1) cable with high-performance modular plugs. Its MaTriX Tape Technology limits alien crosstalk, ensuring 10 Gb/s transmission. The tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.
The Mini-Com Flush Mount Modular Patch Panel accepts up to 24 Mini-Com Modules for unshielded applications in 1 RU, and mounts to 19 inch and 23 inch racks and cabinets. The panel mounts flush with the rack and can be identified with adhesive labels and is black.

CPP24FMWBLY

The Mini-Com Flush Mount Modular Patch Panel accepts up to 24 Mini-Com Modules for unshielded applications in 1 RU, and mounts to 19 inch and 23 inch racks and cabinets. The panel mounts flush with the rack and can be identified with adhesive labels and is black.
Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .

ST4803PDGM

Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .
Ethernet SHDSL Extender

DDW-120

Ethernet SHDSL Extender
24U 21.34W 31.5D CABINET BLK

REFK1904231BK1

24U 21.34W 31.5D CABINET BLK
6U PERF PANEL

PPFS19010BK

6U PERF PANEL
DIN rail is a universal mounting option for electrical and industrial control products such as circuit breakers electrical supplies terminal blocks and more. The rail system is used to stabilize a wide variety of devices and products. Ordering pre-cut DIN rail helps increase productivity and decrease jobsite clutter. On-site Flexibility Streamline custom cuts DIN rail to any length so it is ready to use when it arrives on the jobsite. Additionally DIN rail can be easily removed if relocation is necessary. Features of Custom DIN Rail from Streamline - All cut DIN rail from Streamline is galvanized steel made to eliminate rusting. Streamline ensures that all custom DIN rail orders are: De-burred Custom Length Any quantity 1-1000+ Quick turnaround (typically 2 weeks or less from receipt of order) This mechanical support structure is a must for all electrical parts solutions big or small. DIN rail allows for mounting hardware easily and quickly. These durable and versatile rails make the perfect solution for all mounting applications. Save space time and money with these cost-effective mounting solutions. Order your custom cut DIN rail today!

CUSTOMDIN

DIN rail is a universal mounting option for electrical and industrial control products such as circuit breakers electrical supplies terminal blocks and more. The rail system is used to stabilize a wide variety of devices and products. Ordering pre-cut DIN rail helps increase productivity and decrease jobsite clutter. On-site Flexibility Streamline custom cuts DIN rail to any length so it is ready to use when it arrives on the jobsite. Additionally DIN rail can be easily removed if relocation is necessary. Features of Custom DIN Rail from Streamline - All cut DIN rail from Streamline is galvanized steel made to eliminate rusting. Streamline ensures that all custom DIN rail orders are: De-burred Custom Length Any quantity 1-1000+ Quick turnaround (typically 2 weeks or less from receipt of order) This mechanical support structure is a must for all electrical parts solutions big or small. DIN rail allows for mounting hardware easily and quickly. These durable and versatile rails make the perfect solution for all mounting applications. Save space time and money with these cost-effective mounting solutions. Order your custom cut DIN rail today!
Fiber cable ODC to SC duplex - 670mm

Fiber cable ODC SC Duplex 670mm

Fiber cable ODC to SC duplex - 670mm
Cable Manager, fits 19-inch open rack, Black, Steel

ECK19H

Cable Manager, fits 19-inch open rack, Black, Steel
OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std IL

F62ERLNSNSNM002

OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std IL
Membrane plate cable entry system offers a good strain relief while maintaining IP/NEMA ingress sealing rating. The CESUM3-C15 is a Rectangular Un-Terminated Cable Entry System, 4.1" (103 mm) Long, with 8 Openings 0.12" (3.0 mm) to 0.31" (8 mm), 3 Openings 0.20" (5.1 mm) to 0.35" (9.0 mm), 4 Openings 0.3" (7.5 mm) to 0.47" (12.0 mm). Color is Black. Standard Package Quantity is 1 PC.

CESUM3-C15

Membrane plate cable entry system offers a good strain relief while maintaining IP/NEMA ingress sealing rating. The CESUM3-C15 is a Rectangular Un-Terminated Cable Entry System, 4.1" (103 mm) Long, with 8 Openings 0.12" (3.0 mm) to 0.31" (8 mm), 3 Openings 0.20" (5.1 mm) to 0.35" (9.0 mm), 4 Openings 0.3" (7.5 mm) to 0.47" (12.0 mm). Color is Black. Standard Package Quantity is 1 PC.

Frequently Asked Questions

What is the total number of outlets on this Panduit PDU?

The Panduit E48E20LTAA PDU features a total of 48 outlets, comprising (24) C13/C15 outlets and (24) C13/C15/C19/C21 outlets.

What type of power input connector does the E48E20LTAA use?

This Panduit PDU utilizes an IEC 60309 3-Phase + Neutral + Earth (3P+N+E) 6-hour connector, rated for 30A/32A.

Is the Panduit E48E20LTAA PDU TAA compliant?

Yes, the Panduit E48E20LTAA is a TAA-compliant Enterprise Level 2 (EL2P) Metered PDU.

What is the IP rating of the E48E20LTAA PDU?

The Panduit E48E20LTAA PDU has an IP44 rating, providing protection against solid objects larger than 1mm and water splashes.

What is the power cord length for this PDU?

The Panduit E48E20LTAA PDU comes with a 3-meter power cord.

How to Install a Panduit EL2P Rack Power Distribution Unit (PDU)

This guide provides step-by-step instructions for qualified personnel to safely install a Panduit EL2P Rack Power Distribution Unit (PDU) into a datacenter rack or cabinet, covering mounting, grounding, and power connection.

Estimated time: 1h

Tools needed:

#2 Phillips screwdriver, T10 Torx screwdriver, T20 Torx screwdriver, 2.5mm hex key Allen wrench

Supplies needed:

Ground bonding cable (appropriate gauge per local codes), Cage nuts (for horizontal mounting)

  1. Prepare for Installation and Safety Check

    Before beginning, ensure you are qualified personnel knowledgeable about AC power products. Verify the installation environment is temperature and humidity controlled, indoors, and free of conductive contaminants. Confirm the PDU is intended only for Information Technology Equipment (ITE) loads. Ensure the feed circuit breaker for the power source is in the OFF position before connecting input power.

  2. Mount the PDU in the Rack

    Choose the appropriate mounting method for your PDU form factor (vertical 0U or horizontal 1U/2U). For vertical PDUs, insert the pre-installed mounting buttons into the keyhole slots on the rack's PDU mounting bracket and secure them using a #2 Phillips screwdriver to a torque of 3.0Nm. For horizontal PDUs, install cage nuts at the desired U-locations on both front and rear RETMA rails, then screw the mounting bracket ears into the rails. If necessary, adjust or rotate mounting ears by removing screws, reorienting, and re-fastening. Use a 2.5mm hex key Allen wrench to tighten socket head screws on high-power horizontal PDUs. Ensure a minimum clearance of 2 to 3 inches between the PDU chassis and cabinet frame for proper airflow.

  3. Ground the PDU

    Connect a ground bonding cable of appropriate gauge (meeting national and local electrical codes) to the external ground bonding point on the PDU chassis. This point is typically found on the surface with the outlets and includes an external earthing screw with a star washer. Bond the PDU to the rack metalwork, a grounding strip, or a known earthed reference terminal in the building to ensure a reliable grounded connection and reduce the risk of electric shock due to high leakage currents.

  4. Connect the PDU to a Power Source

    Ensure the feed circuit breaker for the power source is in the OFF position. Verify that all circuit breakers on the PDU itself are set to the ON position. Connect the PDU's input power cord to a grounded (earthed) electrical outlet that is located near the equipment and is easily accessible. Ensure the branch circuit provides appropriate overcurrent protection and adheres to all local and national electrical codes. Verify that devices connected to the PDU are compatible with the line voltage supplying the PDU. Do not overload the PDU; the total input current of connected equipment must not exceed the PDU's total output rating.

  5. Power On and Verify Operation

    Once the PDU is securely mounted, grounded, and connected to the power source, turn the feed circuit breaker to the ON position. Allow time for the PDU's operating system to load. The Main Menu should then display on the PDU screen. For Switched (MS) and Monitored & Switched per Outlet (MSPO) PDUs, observe the LEDs corresponding to each outlet as they power on.

  6. Rotate or Replace Network Controller (Optional)

    If you need to manually rotate the network controller for a specific physical port orientation (as the screen auto-rotates), use a T10 Torx screwdriver to remove the two retaining screws. Carefully disconnect the ribbon cable to prevent damage, then rotate the controller. Reconnect the ribbon cable, ensuring correct orientation and avoiding pinching. If replacing the controller, disconnect the existing ribbon cable, connect it to the new controller, and then mate the new controller to the PDU chassis. Finally, torque the two T10 Torx screws to 2.2–3.1 lbf-in [0.25–0.35 N-M], being careful not to overtighten.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.