Panduit E48D23LTAA - TAA EL2P MI PDU, 20/16 AMP, (24)C13/C15, (24)C13/C15/C19/C21, IEC 60309 3P+N+E 6h 20A/16A (IP44)-3M, BLACK
Panduit

E48D23LTAA

UPC: 613056916166


Documents & Media
BrochureTechnical BulletinTechnical DrawingFull Engineering DrawingInstallation InstructionsSpecification SheetUser ManualOwners Manual

Contact for Pricing

Overview

The Panduit E48D23LTAA is a TAA-compliant, Enterprise Level 2 (EL2P) Metered Input (MI) Power Distribution Unit (PDU). This unit is designed for robust power management in data centers and enterprise environments. It supports a dual current rating of 20 Amps and 16 Amps, accommodating varying power needs. The PDU features a comprehensive outlet configuration: 24 outlets are standard C13/C15 type, while an additional 24 outlets offer expanded compatibility with C13/C15/C19/C21 types. This mixed outlet configuration allows for a diverse range of IT equipment to be connected, from standard servers to higher-power network devices and storage arrays. Power input is via an IEC 60309 3 Phase + Neutral + Earth connector, rated for 6 hours at 20A/16A, with an IP44 rating for protection against solid objects greater than 1mm and water splashes. The PDU is finished in black and includes a 3-meter power cord. SKU: E48D23LTAA. UNSPSC Code: 39121031.
  • TAA Compliant Enterprise Level 2 (EL2P) Metered Input (MI) PDU
  • Dual current rating: 20 Amp / 16 Amp
  • 24 x C13/C15 outlets
  • 24 x C13/C15/C19/C21 outlets for diverse equipment compatibility
  • IEC 60309 3P+N+E 6h 20A/16A (IP44) input connector with 3-meter cord

Specifications

Frequency Rating, Maximum
240 V
Frequency Rating, Minimum
240 V
Material
Metal
Mounting
Vertical
Phase
3
Standard
UL 62368-1, CAN CSA-C22.2 No. 62368-1 EMC: FCC 47 CFR Part 15, Class A, Subpart B. ICES-003 Issue 7
Type
PDU
Width
2 in
Width
50.8 mm
Package Dimensions (L x W x H)
70.08 IN x 3 IN x 3 IN
Package Dimensions (L x W x H)
178.0032 cm x 7.62 cm x 7.62 cm
Package Weight (Imperial)
25.5700 L
Package Weight (Metric)
11.5986 kg
Ethernet SHDSL Extender

DDW-120

Ethernet SHDSL Extender
Fiber cable ODC to SC duplex - 670mm

Fiber cable ODC SC Duplex 670mm

Fiber cable ODC to SC duplex - 670mm
Power supply for DIN-rail

PS-60

Power supply for DIN-rail
DIN Rail ? DIN 35

ARH 1656

DIN Rail ? DIN 35
24U 21.34W 31.5D CABINET BLK

REFK1904231BK1

24U 21.34W 31.5D CABINET BLK
Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .

ST4803PDGM

Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .
Cable Manager, fits 19-inch open rack, Black, Steel

ECK19H

Cable Manager, fits 19-inch open rack, Black, Steel
ON OFF SPST Nickel Pull Chain with Cord

75102CW

ON OFF SPST Nickel Pull Chain with Cord
6U PERF PANEL

PPFS19010BK

6U PERF PANEL
This TX6A 10Gig Cat 6A STP Patch Cord is a 12-Meter, Int'l Grey cord constructed of 26 AWG, shielded, twisted pair, stranded, CM/LSZH cable and with high-performance modular plugs. Its tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. The slender strain relief boot provides easy access in high-density applications. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.

STP6X12MIG

This TX6A 10Gig Cat 6A STP Patch Cord is a 12-Meter, Int'l Grey cord constructed of 26 AWG, shielded, twisted pair, stranded, CM/LSZH cable and with high-performance modular plugs. Its tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. The slender strain relief boot provides easy access in high-density applications. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.
OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std IL

F62ERLNSNSNM002

OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std IL
Membrane plate cable entry system offers a good strain relief while maintaining IP/NEMA ingress sealing rating. The CESUM3-C15 is a Rectangular Un-Terminated Cable Entry System, 4.1" (103 mm) Long, with 8 Openings 0.12" (3.0 mm) to 0.31" (8 mm), 3 Openings 0.20" (5.1 mm) to 0.35" (9.0 mm), 4 Openings 0.3" (7.5 mm) to 0.47" (12.0 mm). Color is Black. Standard Package Quantity is 1 PC.

CESUM3-C15

Membrane plate cable entry system offers a good strain relief while maintaining IP/NEMA ingress sealing rating. The CESUM3-C15 is a Rectangular Un-Terminated Cable Entry System, 4.1" (103 mm) Long, with 8 Openings 0.12" (3.0 mm) to 0.31" (8 mm), 3 Openings 0.20" (5.1 mm) to 0.35" (9.0 mm), 4 Openings 0.3" (7.5 mm) to 0.47" (12.0 mm). Color is Black. Standard Package Quantity is 1 PC.

Frequently Asked Questions

What is the maximum operating temperature for Panduit PDUs?

Panduit PDUs are built with premium components to withstand 140°F (60°C) at full load, ensuring reliable operation in high-temperature environments.

What warranty is offered for Panduit EL2P PDUs?

EL2P PDUs come with a 5-year standard warranty plus a 1-year extended warranty.

Are Panduit intelligent PDUs compatible with Cisco Nexus Dashboard?

Yes, Panduit's intelligent PDUs seamlessly integrate with Cisco Nexus Dashboard software to enhance energy savings and sustainability insights.

What network connectivity does the EL2P PDU offer?

The EL2P PDU offers dual 1Gb Ethernet and serial connectivity. It also supports Wi-Fi and Bluetooth via the CNT06 accessory.

What is the metering accuracy of EL2P series PDUs?

EL2P series PDUs provide a metering accuracy of ± 0.5%.

Does the EL2P PDU have a hot-swappable controller?

Yes, the EL2P PDU features an auto-rotatable, hot-swappable controller that can be removed without affecting outlet status.

What security features are included with EL2P PDUs?

EL2P PDUs include SNMPv3, TLS, encrypted protocols, UL-2900-1, IEEE 802.1X, IEC 62443-4-2, USGv6, and Secure Code Signing.

What are the input power specifications for the E48D23L PDU?

The E48D23L PDU has a 3-phase input, with apparent power of 11.5 kVA (NA) or 11.0 kVA (EMEA), and input current of 20A (NA) or 16A (EMEA) per phase.

What types of outlets does the E48D23L PDU provide?

The E48D23L PDU provides 48 outlets: 24 are C13/C15, and 24 are combination C13/C15/C19/C21.

What is the form factor of the E48D23L PDU?

The E48D23L PDU has a 0U WIDE form factor.

How to Install a Panduit EL2P PDU

This guide provides detailed instructions for qualified personnel to install a Panduit EL2P Rack Power Distribution Unit (PDU) into a datacenter rack or cabinet, covering mounting, grounding, and power connection.

Estimated time: 1h

Tools needed:

#2 Phillips screwdriver, T10 Torx screwdriver, 2.5mm hex key Allen wrench

Supplies needed:

Mounting hardware (e.g., screws, cage nuts), Ground bonding cable

  1. Mount the PDU

    Mount the PDU securely within the datacenter rack or cabinet. For vertical PDUs, insert mounting buttons into keyhole slots on the rack's mounting bracket and secure with a #2 Phillips screwdriver to 3.0Nm. For horizontal PDUs, install cage nuts at the desired U location and attach mounting bracket ears to the RETMA rails, using a 2.5mm hex key Allen wrench for high-power units. Ensure proper clearance (2-3 inches) for airflow and seal unused rack spaces with blanking panels.

  2. Ground the PDU

    Connect a ground bonding cable from the external ground bonding point on the PDU chassis to a known earthed reference terminal in the building or a grounding strip/bus bar in the rack. Ensure conductor sizes meet national or local electrical codes. This step is crucial for safety and to reduce the risk of electric shock due to high leakage currents. Bond the PDU to the rack metalwork using the external earthing screw and star washer.

  3. Rotate the Network Controller (Optional)

    If a specific orientation of the physical ports is desired, manually rotate the network controller. Use a T10 Torx screwdriver to remove the two retaining screws. Disconnect the ribbon cable, rotate the controller, then carefully reconnect the ribbon cable, avoiding pinching. Reinstall and torque the screws to 2.2–3.1 lbf-in [0.25–0.35 N-M]. DANGER: This PDU contains LETHAL VOLTAGES. Only qualified personnel should perform this task.

  4. Connect the PDU to a Power Source

    Before connecting, ensure the feed circuit breaker is OFF and all circuit breakers on the PDU are set to ON. Connect the PDU's input power cord to an appropriately rated, grounded branch circuit, adhering to all local and national electrical codes. Turn the feed circuit breaker ON and wait for the operating system to load. Verify the connected devices are compatible with the PDU's line voltage to prevent equipment damage. Do not overload the PDU; total input current must not exceed the PDU's output rating.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.