Authorized Panduit Distributor
Panduit E42G03LTAA - TAA EL2P MSPO PDU, 30/32 AMP, (21)C13/C15, (21)C13/C15/C19/C21, IEC 60309 2P+E 6h 30A/32A (IP44)-3M, BLACK
Panduit

E42G03LTAA

UPC: 613056915961


Documents & Media
BrochureTechnical BulletinTechnical DrawingFull Engineering DrawingInstallation InstructionsSpecification SheetUser ManualOwners Manual

Contact for Pricing

Overview

The Panduit E42G03LTAA is a TAA-compliant, 30/32 Amp, 2-pole + Earth (2P+E) 6h IEC 60309 power distribution unit (PDU) designed for reliable power delivery in data centers and industrial environments. This MSPO (Modular Smart Power Outlet) model features a total of 42 outlets, configured as 21 outlets supporting C13/C15 connectors and an additional 21 outlets supporting C13/C15/C19/C21 connectors. This extensive outlet configuration provides flexibility for a wide range of IT equipment, including servers, network switches, and storage devices. The unit is equipped with a 3-meter power cord featuring an IEC 60309 2P+E 6h 30A/32A plug, ensuring compatibility with standard industrial power sources. The IP44 rating indicates protection against solid objects larger than 1mm and splashing water, suitable for controlled environments. The black color finish is standard for industrial equipment. This PDU is manufactured by Panduit, a recognized leader in network infrastructure solutions. SKU: E42G03LTAA. UNSPSC Code: 39121031.
  • TAA Compliant for government and regulated environments
  • 42 Outlets: 21x C13/C15, 21x C13/C15/C19/C21 for diverse equipment connectivity
  • 30/32 Ampere rating for substantial power delivery
  • IEC 60309 2P+E 6h 30A/32A plug with a 3-meter cord
  • IP44 rated for protection against splashing water and solid objects

Specifications

Frequency Rating, Maximum
230 V
Frequency Rating, Minimum
230 V
Material
Metal
Mounting
Vertical
Phase
1
Standard
UL 62368-1, CAN CSA-C22.2 No. 62368-1 EMC: FCC 47 CFR Part 15, Class A, Subpart B. ICES-003 Issue 7
Type
PDU
Width
2 in
Width
50.8 mm
Package Dimensions (L x W x H)
70.08 IN x 3 IN x 3 IN
Package Dimensions (L x W x H)
178.0032 cm x 7.62 cm x 7.62 cm
Package Weight (Imperial)
22.0500 L
Package Weight (Metric)
10.0019 kg
Power supply for DIN-rail

PS-60

Power supply for DIN-rail
The TX6A™ 10Gig Cat 6A UTP Patch Cord is a 1-Meter, Blue cord constructed of 24 AWG, unshielded, twisted pair stranded, LSZH (60332-1) cable with high-performance modular plugs. Its MaTriX Tape Technology limits alien crosstalk, ensuring 10 Gb/s transmission. The tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.

UTP6AL1MBU

The TX6A™ 10Gig Cat 6A UTP Patch Cord is a 1-Meter, Blue cord constructed of 24 AWG, unshielded, twisted pair stranded, LSZH (60332-1) cable with high-performance modular plugs. Its MaTriX Tape Technology limits alien crosstalk, ensuring 10 Gb/s transmission. The tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.
5-port Ethernet Switch

SDI-550

5-port Ethernet Switch
The Mini-Com Flush Mount Modular Patch Panel accepts up to 24 Mini-Com Modules for unshielded applications in 1 RU, and mounts to 19 inch and 23 inch racks and cabinets. The panel mounts flush with the rack and can be identified with adhesive labels and is black.

CPP24FMWBLY

The Mini-Com Flush Mount Modular Patch Panel accepts up to 24 Mini-Com Modules for unshielded applications in 1 RU, and mounts to 19 inch and 23 inch racks and cabinets. The panel mounts flush with the rack and can be identified with adhesive labels and is black.
Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .

ST4803PDGM

Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .
24U 21.34W 31.5D CABINET BLK

REFK1904231BK1

24U 21.34W 31.5D CABINET BLK
6U PERF PANEL

PPFS19010BK

6U PERF PANEL
DIN rail is a universal mounting option for electrical and industrial control products such as circuit breakers electrical supplies terminal blocks and more. The rail system is used to stabilize a wide variety of devices and products. Ordering pre-cut DIN rail helps increase productivity and decrease jobsite clutter. On-site Flexibility Streamline custom cuts DIN rail to any length so it is ready to use when it arrives on the jobsite. Additionally DIN rail can be easily removed if relocation is necessary. Features of Custom DIN Rail from Streamline - All cut DIN rail from Streamline is galvanized steel made to eliminate rusting. Streamline ensures that all custom DIN rail orders are: De-burred Custom Length Any quantity 1-1000+ Quick turnaround (typically 2 weeks or less from receipt of order) This mechanical support structure is a must for all electrical parts solutions big or small. DIN rail allows for mounting hardware easily and quickly. These durable and versatile rails make the perfect solution for all mounting applications. Save space time and money with these cost-effective mounting solutions. Order your custom cut DIN rail today!

CUSTOMDIN

DIN rail is a universal mounting option for electrical and industrial control products such as circuit breakers electrical supplies terminal blocks and more. The rail system is used to stabilize a wide variety of devices and products. Ordering pre-cut DIN rail helps increase productivity and decrease jobsite clutter. On-site Flexibility Streamline custom cuts DIN rail to any length so it is ready to use when it arrives on the jobsite. Additionally DIN rail can be easily removed if relocation is necessary. Features of Custom DIN Rail from Streamline - All cut DIN rail from Streamline is galvanized steel made to eliminate rusting. Streamline ensures that all custom DIN rail orders are: De-burred Custom Length Any quantity 1-1000+ Quick turnaround (typically 2 weeks or less from receipt of order) This mechanical support structure is a must for all electrical parts solutions big or small. DIN rail allows for mounting hardware easily and quickly. These durable and versatile rails make the perfect solution for all mounting applications. Save space time and money with these cost-effective mounting solutions. Order your custom cut DIN rail today!
Fiber cable ODC to SC duplex - 670mm

Fiber cable ODC SC Duplex 670mm

Fiber cable ODC to SC duplex - 670mm
Cable Manager, fits 19-inch open rack, Black, Steel

ECK19H

Cable Manager, fits 19-inch open rack, Black, Steel
OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std IL

F62ERLNSNSNM002

OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std IL
Membrane plate cable entry system offers a good strain relief while maintaining IP/NEMA ingress sealing rating. The CESUM3-C15 is a Rectangular Un-Terminated Cable Entry System, 4.1" (103 mm) Long, with 8 Openings 0.12" (3.0 mm) to 0.31" (8 mm), 3 Openings 0.20" (5.1 mm) to 0.35" (9.0 mm), 4 Openings 0.3" (7.5 mm) to 0.47" (12.0 mm). Color is Black. Standard Package Quantity is 1 PC.

CESUM3-C15

Membrane plate cable entry system offers a good strain relief while maintaining IP/NEMA ingress sealing rating. The CESUM3-C15 is a Rectangular Un-Terminated Cable Entry System, 4.1" (103 mm) Long, with 8 Openings 0.12" (3.0 mm) to 0.31" (8 mm), 3 Openings 0.20" (5.1 mm) to 0.35" (9.0 mm), 4 Openings 0.3" (7.5 mm) to 0.47" (12.0 mm). Color is Black. Standard Package Quantity is 1 PC.

Frequently Asked Questions

What is the metering accuracy of Panduit PDUs?

Panduit PDUs offer metering accuracy of ± 2% for ES2P and G6 models, and ± 0.5% for EL2P models.

Can Panduit PDUs be used globally with different power requirements?

Yes, Universal Inlet PDUs can be deployed globally by swapping the input cord, allowing power scaling from 5kW to 27.6kW.

How are Panduit PDUs mounted in a rack?

Panduit PDUs feature tool-less mounting, allowing effortless installation into a rack using a convenient button slot.

What types of outlets do combination outlets support?

Combination outlets provide ultimate flexibility, allowing each outlet to be used as a C21, C19, C15, or C13.

What type of circuit protection do Basic PDUs have?

Basic PDUs are equipped with built-in magnetic hydraulic circuit breakers, providing robust defense against short circuits and overloads.

Which PDU series are compatible with SiteCommand Utility software?

SiteCommand Utility software is compatible with Panduit's ES2P and EL2P series PDUs.

What are the warranty options for Panduit PDU series?

ES2P and G6 series have a 3-year standard plus 2-year extended warranty. The EL2P series offers a 5-year standard plus 1-year extended warranty.

What is the maximum operating temperature for Panduit PDUs?

Panduit PDUs are built with premium components to withstand 140°F (60°C) at full load.

Do Panduit PDUs feature hot-swappable controllers?

Yes, Panduit PDUs feature hot-swappable controllers, some with large OLED displays, allowing removal without affecting outlet status.

What can Panduit PDUs monitor in real-time?

Panduit PDUs offer real-time monitoring of power, environmental conditions, and cabinet security.

How to Install the Panduit EL2P Power Distribution Unit (PDU)

This guide provides step-by-step instructions for qualified personnel to install a Panduit EL2P PDU into a datacenter rack or cabinet, covering mounting, grounding, and connecting to a power source.

Estimated time: 45m

Tools needed:

#2 Phillips screwdriver, T10 Torx screwdriver, T20 Torx screwdriver, 2.5mm hex key Allen wrench

Supplies needed:

Ground bonding cable, Cage nuts, Blanking panels

  1. Install Mounting Hardware for Horizontal PDUs

    For horizontal PDUs, install cage nuts at the desired U location on both front and rear equipment rails. Screw the mounting bracket ears into the front and rear RETMA rail surfaces where the cage nuts were installed. For high-power 1U/2U PDUs, screw the mounting brackets on the front into the PDU chassis using a 2.5mm hex key Allen wrench. Note: For vertical PDUs, mounting buttons are typically pre-installed at the factory.

  2. Mount the PDU in the Rack

    For Vertical PDUs: Insert the PDU's pre-installed mounting buttons into the keyhole slots on the rack's PDU mounting bracket. Secure them using a #2 Phillips screwdriver to a recommended torque of 3.0Nm. Ensure outlets face the center of the rack. For Horizontal PDUs: Install the PDU by aligning its mounting ears with the previously installed cage nuts and mounting brackets, then secure it. Safety Warning: When installing 100A/125A PDUs, maintain 2-3 inches clearance from cabinet frame/side panels to avoid blocking exhaust airflow. Seal unused rack spaces with blanking panels.

  3. Ground the PDU

    Connect a ground bonding cable from the external ground bonding point on the PDU chassis (typically near the outlets) to a known earthed reference terminal in the building or a grounding strip/bus bar in the rack. Use the external earthing screw with a star washer for supplementary Earth bonding to the rack metalwork. Ensure conductor sizes meet national or local electrical codes. Safety Warning: HIGH LEAKAGE CURRENT. Ensure a reliable grounded (earthed) connection before connecting power distribution products to AC power.

  4. Connect the PDU to a Power Source

    Before connecting: Turn the feed circuit breaker OFF and ensure all PDU circuit breakers are ON. Connect the PDU's input power cord to an appropriately rated branch circuit, following all local and national electrical codes. Refer to the PDU's compliance label for input ratings. After connecting: Turn the feed circuit breaker ON. Wait for the operating system to load until the Main Menu displays. Safety Warning: Connect only to a circuit with appropriate overcurrent protection and a grounded, accessible outlet. Do not overload the PDU.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.