Contact for Pricing
Overview
- Frequency range: 440-475 MHz for UHF applications
- Gain: 8 dBi with vertical polarization for directional signal transmission
- Connector: N-/TNC-female for versatile RF system compatibility
- Radome: ABS/FG PU foam for environmental durability and UV resistance
- Mounting: 35-60 mm pole diameter support with 128 N wind load rating
Specifications
Connector | N-/TNC-female |
Frequency | 440-475 MHz |
Gain | 8 dBi |
Length | 2295 mm |
Mounting Diameter | Ø 35-60 |
Polarization | vertical |
Radiator Material | copper |
Radome | ABS/FG, PU foam |
VSWR | <1.5 |
Weight | 3430 g |
Wind Load | 128 N @ 150 km/h |

CA420N4
cardioid pattern notch - Frequency range: 405-440 MHz - Gain: 8 dBi - Polarization: vertical - Connector: N-/TNC-female - VSWR: <1.5 - Radome: ABS/FG PU foam - Radiator material: copper - Mounting: 35-60 mm diameter pole - Wind load: 132 N
CA350N4
cardioid pattern notch - Frequency range: 336-364 MHz - Gain: 8 dBi - Polarization: vertical - Connector: N-/TNC-female - VSWR: <1.5 - Radome: ABS/FG PU foam - Radiator material: copper - Mounting: 35-60 mm diameter pole - Wind load: 144 N
CA400N4
cardioid pattern notch - Frequency range: 380-410 MHz - Gain: 8 dBi - Polarization: vertical - Connector: N-/TNC-female - VSWR: <1.5 - Radome: ABS/FG PU foam - Radiator material: copper - Mounting: 35-60 mm diameter pole - Wind load: 136 N
CA380N4
cardioid pattern notch - Frequency range: 365-395 MHz - Gain: 8 dBi - Polarization: vertical - Connector: N-/TNC-female - VSWR: <1.5 - Radome: ABS/FG PU foam - Radiator material: copper - Mounting: 35-60 mm diameter pole - Wind load: 140 N
CA340N4
cardioid pattern notch - Frequency range: 326-353 MHz - Gain: 8 dBi - Polarization: vertical - Connector: N-/TNC-female - VSWR: <1.5 - Radome: ABS/FG PU foam - Radiator material: copper - Mounting: 35-60 mm diameter pole - Wind load: 144 N
CA930C2
offset pattern collinear - Frequency range: 880-960 MHz - Gain: 8 dBi - Polarization: vertical - Connector: N-female - VSWR: <1.5 - Radome: ABS/FG PU foam - Radiator material: copper - Mounting: 35-60 mm diameter pole - Wind load: 50 N
CA860C2
offset pattern collinear - Frequency range: 830-890 MHz - Gain: 8 dBi - Polarization: vertical - Connector: N-female - VSWR: <1.5 - Radome: ABS/FG PU foam - Radiator material: copper - Mounting: 35-60 mm diameter pole - Wind load: 50 N
CA450C2
offset pattern collinear - Frequency range: 440-475 MHz - Gain: 8 dBi - Polarization: vertical - Connector: N-/TNC-female - VSWR: <1.5 - Radome: ABS/FG PU foam - Radiator material: copper - Mounting: 35-60 mm diameter pole - Wind load: 64 N
CA150C2
offset pattern collinear - Frequency range: 144-156 MHz - Gain: 8 dBi - Polarization: vertical - Connector: N-/TNC-female - VSWR: <1.5 - Radome: ABS/FG PU foam - Radiator material: copper - Mounting: 35-60 mm diameter pole - Wind load: 120 N
CA420C2
offset pattern collinear - Frequency range: 405-440 MHz - Gain: 8 dBi - Polarization: vertical - Connector: N-/TNC-female - VSWR: <1.5 - Radome: ABS/FG PU foam - Radiator material: copper - Mounting: 35-60 mm diameter pole - Wind load: 66 N
CA230C2
offset pattern collinear - Frequency range: 221-239 MHz - Gain: 8 dBi - Polarization: vertical - Connector: N-/TNC-female - VSWR: <1.5 - Radome: ABS/FG PU foam - Radiator material: copper - Mounting: 35-60 mm diameter pole - Wind load: 90 N
CA140C2
offset pattern collinear - Frequency range: 135-145 MHz - Gain: 8 dBi - Polarization: vertical - Connector: N-/TNC-female - VSWR: <1.5 - Radome: ABS/FG PU foam - Radiator material: copper - Mounting: 35-60 mm diameter pole - Wind load: 126 NHow to Install the CA450N4 Controller
Step-by-step guide for installing and configuring the CA450N4 Controller for optimal performance.
Estimated time: 1h
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Wire connectors, Self-amalgamating tape
- Mount the controller
Secure the CA450N4 controller to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.
- Connect the wiring
Use wire connectors to attach the power and signal wires to the appropriate terminals on the CA450N4 controller. Ensure all connections are tight and secure.
- Seal the connections
Cover all connectors and cable junctions with self-amalgamating tape to provide weather protection and prevent moisture ingress.
- Verify the installation
Use a multimeter to check the voltage at the controller terminals to ensure proper power supply. Confirm that all connections are functioning correctly.
- Configure the controller
Follow the manufacturer's instructions to program the CA450N4 controller settings according to your application requirements.
- Calibrate the system
Perform any necessary calibration procedures as outlined in the user manual to ensure accurate operation of the CA450N4 controller.