Contact for Pricing
Overview
- Frequency range: 440-475 MHz
- Gain: 8 dBi with vertical polarization
- Connector: N-/TNC-female for versatile compatibility
- VSWR <1.5 for minimal signal reflection
- IP67 rated, -40°C to +80°C operating range
Specifications
Connection Type | N-/TNC-female |
Connector | N-/TNC-female |
Frequency | 440-475 MHz |
Gain | 8 dBi |
Length | 985 mm |
Material | ABS/FG PU foam, copper |
Mounting Diameter | Ø 35-60 |
Mounting Type | 35-60 mm diameter pole |
Polarization | vertical |
Radiator Material | copper |
Radome | ABS/FG, PU foam |
Series | CA450C2 |
VSWR | <1.5 |
Weight | 1590 g |
Wind Load | 64 N @ 150 km/h |

CA230C2
offset pattern collinear - Frequency range: 221-239 MHz - Gain: 8 dBi - Polarization: vertical - Connector: N-/TNC-female - VSWR: <1.5 - Radome: ABS/FG PU foam - Radiator material: copper - Mounting: 35-60 mm diameter pole - Wind load: 90 N
CA170C2
offset pattern collinear - Frequency range: 163-177 MHz - Gain: 8 dBi - Polarization: vertical - Connector: N-/TNC-female - VSWR: <1.5 - Radome: ABS/FG PU foam - Radiator material: copper - Mounting: 35-60 mm diameter pole - Wind load: 110 N
CA400C2
offset pattern collinear - Frequency range: 380-410 MHz - Gain: 8 dBi - Polarization: vertical - Connector: N-/TNC-female - VSWR: <1.5 - Radome: ABS/FG PU foam - Radiator material: copper - Mounting: 35-60 mm diameter pole - Wind load: 68 N
CA350C2
offset pattern collinear - Frequency range: 336-364 MHz - Gain: 8 dBi - Polarization: vertical - Connector: N-/TNC-female - VSWR: <1.5 - Radome: ABS/FG PU foam - Radiator material: copper - Mounting: 35-60 mm diameter pole - Wind load: 72 N
CA340C2
offset pattern collinear - Frequency range: 326-353 MHz - Gain: 8 dBi - Polarization: vertical - Connector: N-/TNC-female - VSWR: <1.5 - Radome: ABS/FG PU foam - Radiator material: copper - Mounting: 35-60 mm diameter pole - Wind load: 72 N
CA380C2
offset pattern collinear - Frequency range: 365-395 MHz - Gain: 8 dBi - Polarization: vertical - Connector: N-/TNC-female - VSWR: <1.5 - Radome: ABS/FG PU foam - Radiator material: copper - Mounting: 35-60 mm diameter pole - Wind load: 70 N
CA230C3
offset pattern collinear - Frequency range: 221-239 MHz - Gain: 10 dBi - Polarization: vertical - Connector: N-/TNC-female - VSWR: <1.5 - Radome: ABS/FG PU foam - Radiator material: copper - Mounting: 35-60 mm diameter pole - Wind load: 135 N
CA150C3
offset pattern collinear - Frequency range: 144-156 MHz - Gain: 10 dBi - Polarization: vertical - Connector: N-/TNC-female - VSWR: <1.5 - Radome: ABS/FG PU foam - Radiator material: copper - Mounting: 35-60 mm diameter pole - Wind load: 180 N
CA85C3
offset pattern collinear - Frequency range: 83-88 MHz - Gain: 10 dBi - Polarization: vertical - Connector: N-/TNC-female - VSWR: <1.5 - Radome: ABS/FG PU foam - Radiator material: copper - Mounting: 35-60 mm diameter pole - Wind load: 189 N
CA450C3
offset pattern collinear - Frequency range: 440-475 MHz - Gain: 10 dBi - Polarization: vertical - Connector: N-/TNC-female - VSWR: <1.5 - Radome: ABS/FG PU foam - Radiator material: copper - Mounting: 35-60 mm diameter pole - Wind load: 96 N
CA930C4
offset pattern collinear - Frequency range: 880-960 MHz - Gain: 11 dBi - Polarization: vertical - Connector: N-female - VSWR: <1.5 - Radome: ABS/FG PU foam - Radiator material: copper - Mounting: 35-60 mm diameter pole - Wind load: 100 N
CA160C4
offset pattern collinear - Frequency range: 154-166 MHz - Gain: 11 dBi - Polarization: vertical - Connector: N-/TNC-female - VSWR: <1.5 - Radome: ABS/FG PU foam - Radiator material: copper - Mounting: 35-60 mm diameter pole - Wind load: 228 NHow to Install the CA450C2 Controller
This guide provides step-by-step instructions for installing and configuring the CA450C2 Controller, ensuring proper wiring and calibration for optimal performance.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Self-amalgamating tape, Terminal connectors
- Mount the controller
Secure the CA450C2 controller to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.
- Connect the wiring
Use terminal connectors to connect the power and signal wires to the appropriate terminals on the CA450C2 controller. Refer to the wiring diagram for correct terminal assignments.
- Seal the connections
Cover all connectors and cable junctions with self-amalgamating tape to ensure proper weather protection and prevent moisture ingress.
- Verify the connections
Use a multimeter to check the voltage at the controller terminals to ensure proper power supply before powering on the device.
- Power on the controller
Turn on the power supply to the CA450C2 controller and observe the indicator lights to confirm that the device is functioning correctly.
- Calibrate the controller
Follow the calibration procedure outlined in the user manual to ensure the controller is accurately configured for your specific application.