- Frequency range: 154-166 MHz
- Gain: 11 dBi with vertical polarization
- VSWR: <1.5 for minimal signal reflection
- IP67-rated UV-resistant ABS/FG PU radome
- Mounting: 35-60 mm diameter pole with aluminum bracket
- Wind load: 228 N for outdoor stability
- DC short-circuited feed point for lightning protection
- Operating temperature: -40°C to +80°C
Specifications
Connector | N-/TNC-female |
Frequency | 154-166 MHz |
Gain | 11 dBi |
Length | 6530 mm |
Material | ABS/FG PU foam, copper |
Mounting Diameter | Ø 35-60 |
Mounting Type | 35-60 mm diameter pole |
Polarization | vertical |
Radiator Material | copper |
Radome | FG, PU foam |
Series | CA160C4 |
VSWR | <1.5 |
Weight | 4610 g |
Wind Load | 228 N @ 150 km/h |

CA930C4
offset pattern collinear - Frequency range: 880-960 MHz - Gain: 11 dBi - Polarization: vertical - Connector: N-female - VSWR: <1.5 - Radome: ABS/FG PU foam - Radiator material: copper - Mounting: 35-60 mm diameter pole - Wind load: 100 NHow to Install the CA160C4 Controller
This guide provides step-by-step instructions for installing and configuring the CA160C4 Controller, ensuring proper wiring and initial setup.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Wire connectors, Self-amalgamating tape
- Mount the controller
Secure the CA160C4 controller to the designated mounting surface using the provided mounting screws. Ensure it is level and firmly attached.
- Connect the wiring
Use wire connectors to connect the power and signal wires to the appropriate terminals on the CA160C4 controller. Refer to the wiring diagram for correct terminal assignments.
- Seal the connections
Cover all connectors and cable junctions with self-amalgamating tape to ensure proper weather protection and prevent moisture ingress.
- Verify connections
Use a multimeter to check the voltage at the controller terminals to ensure proper power supply. Confirm that all connections are secure.
- Initial configuration
Power on the CA160C4 controller and follow the on-screen prompts to complete the initial setup and configuration.