Authorized ABB Distributor (Installation Products)
ABB - Installation Products STX150-471PVC - Star Teck XP hazardous location PVC coated jacketed cable fitting hub size 1-1/2 inches Range over jacket 1.600-1.875 inches.

ABB Installation Products STX150-471PVC Star Teck XP hazardous location PVC coated jacketed cable fitting hub size 1-1/2 inches…

UPC: 786210843148


Documents & Media
Installation InstructionsSpecification SheetVideo ClipManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB STX150-471PVC Star Teck XP fitting is engineered for hazardous location installations, specifically designed for use with jacketed cables. Developed in collaboration with engineers from the petrochemical, oil and gas industries, this fitting sets a benchmark for ease of installation in challenging environments. Its integral sealing chamber is designed for straightforward filling, and the disconnectable nature of the fitting minimizes the need for extensive cable preparation. This approach significantly streamlines the installation process. Key specifications for the STX150-471PVC include a hub size of 1-1/2 inches. The fitting accommodates a range over jacket diameter from 1.600 to 1.875 inches, ensuring compatibility with a defined range of cable sizes. The PVC coated jacket provides a protective layer suitable for specific hazardous area classifications. This product is part of the ABB Installation Products portfolio, known for its reliable electrical solutions. The development of this fitting was concurrent with a line of specialized liquid and putty sealants, which replaced older cement-based sealing methods, further enhancing safety and efficiency in hazardous area applications. SKU: STX150-471PVC. UNSPSC Code: 39121311.
  • Working with engineers from the petrochemical, oil and gas industries, Thomas & Betts then introduced the STAR TECK XP fitting.
  • With an easy-to-fill, integral sealing chamber and a disconnectable design requiring minimal cable preparation, this fitting became the benchmark for ease of installation in hazardous environments.
  • A line of liquid and putty sealants was also developed at the same time, eliminating the need for the cement sealants used up to this point.
  • PVC coated jacket for protection
  • Integral sealing chamber for easy filling

Specifications

Application
For Hazardous Locations
Color
Black
Finish
PVC
Material
Aluminum
Size
1-1/2 Inches
Standard
CSA 23086
Type
Teck Cable Fittings
Package Dimensions (L x W x H)
5 IN x 8 IN x 4 IN
Package Dimensions (L x W x H)
12.7 cm x 20.32 cm x 10.16 cm
Package Weight (Imperial)
1.6500 L
Package Weight (Metric)
0.7480 kg
Star Teck jacketed cable fitting PVC coated. Hub size of 2-1/2 inches. Range over jacket from 2.380 - 2.640 inches.

ST250-477PVC

Star Teck jacketed cable fitting PVC coated. Hub size of 2-1/2 inches. Range over jacket from 2.380 - 2.640 inches.
Entrance Cap, Threaded, Aluminum, Size 2-1/2 Inch

1207

Entrance Cap, Threaded, Aluminum, Size 2-1/2 Inch
Star Teck XP hazardous location PVC coated jacketed cable fitting hub size 1-1/2 inches Range over jacket 1.500-1.625 inches.

STX150-550PVC

Star Teck XP hazardous location PVC coated jacketed cable fitting hub size 1-1/2 inches Range over jacket 1.500-1.625 inches.
Star Teck XP hazardous location PVC coated jacketed cable fitting hub size 1 inch Range over jacket 1.025-1.205 inches.

STX100-468PVC

Star Teck XP hazardous location PVC coated jacketed cable fitting hub size 1 inch Range over jacket 1.025-1.205 inches.
Star Teck XP hazardous location PVC coated jacketed cable fitting hub size 2 inches Range over jacket 1.900-2.187 inches.

STX200-473PVC

Star Teck XP hazardous location PVC coated jacketed cable fitting hub size 2 inches Range over jacket 1.900-2.187 inches.
Star Teck XP hazardous location PVC coated jacketed cable fitting hub size 2 inches Range over jacket 2.100-2.375 inches.

STX200-474PVC

Star Teck XP hazardous location PVC coated jacketed cable fitting hub size 2 inches Range over jacket 2.100-2.375 inches.
Aluminum PVC coated fitting with a hub size of 3 inches and the outer jacket diameters from 2.79 to 3.06 inches.

STX300-479PVC

Aluminum PVC coated fitting with a hub size of 3 inches and the outer jacket diameters from 2.79 to 3.06 inches.
Star Teck XP hazardous location PVC coated jacketed cable fitting hub size 3 inches Range over jacket 2.580-2.840 inches.

STX300-478PVC

Star Teck XP hazardous location PVC coated jacketed cable fitting hub size 3 inches Range over jacket 2.580-2.840 inches.

Frequently Asked Questions

What sealing compounds are required for installation?

The STX150-471PVC must be installed with either SC4-KIT-1 liquid compound or SC65 putty sealing compound, which are sold separately.

Is the product suitable for wet and dry locations?

Yes, the product conforms to UL514B and CSA C22.2-18.3 for use in both wet and dry locations.

What is the cable armor diameter range for STX150-471PVC?

The range over the cable armor for STX150-471PVC is 37.47 mm (1.475 in) minimum to 45.59 mm (1.795 in) maximum.

What is the cable jacket diameter range for STX150-471PVC?

The range over the cable jacket for STX150-471PVC is 40.64 mm (1.600 in) minimum to 47.63 mm (1.875 in) maximum.

What is the NPT thread size for the STX150-471PVC?

The STX150-471PVC has a 1-1/2 NPT thread size.

Is the product RoHS compliant?

Yes, the product conforms to the RoHS (Restriction of Hazardous Substances Directive) 2011/65/EU, incorporating the 2015/863 amendment.

What hazardous location classifications does this product meet?

The product conforms to Class I Div1 ABCD, Class II Div1 EFG, and Class III Div1 under CSA 22.2 and UL2225 standards.

What is the ingress protection rating?

The product has an ingress protection rating of Type 4 / 4X.

What is the operating temperature range for this product?

The normal working temperature range for the product is -40 to +90°C (-40 to +194°F).

When should I use SC4-KIT-1 or SC65 sealing compound?

Use SC4-KIT-1 for shielded cables or cables with 5 or more conductors. SC65 is suitable for cables with a maximum of 4 conductors and is not recommended for shielded cables.

How to Install the STX150-471PVC Star Teck Cable Fitting

This guide provides detailed instructions for preparing, installing, and sealing the STX150-471PVC Star Teck PVC cable fitting for power or shielded data cables, ensuring a secure and compliant connection in hazardous locations.

Estimated time: 1h 30m

Tools needed:

Hacksaw, Strap wrenches, Wooden dowel (for putty sealant), Multimeter

Supplies needed:

SC4-KIT-1 LIQUID SEALANT or SC65 PUTTY SEALANT, Fiber damming material (for liquid sealant), Lubricant, Gloves, Personal Protective Equipment (PPE)

  1. De-energize Circuits and Review Safety

    Before beginning installation or performing maintenance, verify that all circuits are de-energized to prevent the risk of electrical shock. Ensure the installation is performed by a qualified electrician in accordance with national and local electrical codes. Wear appropriate Personal Protective Equipment (PPE).

  2. Prepare Cable Armor

    Determine the required working length of conductors inside the enclosure or device. Carefully remove a portion of the cable's outer jacket to expose the armor. Using a hacksaw, cut the armor to the desired length, taking extreme caution not to nick or cut the conductor insulation. For the STX150-471PVC, trim the outer jacket to expose an armor strip length of 1-3/4 inches.

  3. Prepare the Cable Boot

    Choose one of the following methods to prepare the cable boot: Method 1: Unscrew the gland nut from the body, force the square-cut cable into the boot, and then cut the boot in front of the cable. Method 2: Strip the cable jacket off the armor, then progressively cut slices off the boot until the opening can snugly slide onto the armor. Note: For PVC coated fittings, use strap wrenches only for installation. Apply lubricant where indicated prior to screwing the gland nut.

  4. Feed Cable and Tighten Gland Nut

    Feed the prepared cable through the gland nut opening and push it until the cable armor firmly hits the internal end stop. Tighten the gland nut until an appropriate seal is obtained or to the maximum torque of 1200 IN-LBS for the STX150-471PVC. Ensure the bushing seals evenly around the cable’s outer jacket and the cable remains centered for an optimal seal.

  5. Disassemble Fitting for Sealing and Prepare Power Cable Conductors

    Disassemble the hub from the body sub-assembly by loosening the union. Then, unscrew the sealing chamber from the body sub-assembly. For power cables, trim the inner jacket to a length of 1/8 to 3/8 inches to expose the conductor bundle. If installing shielded data cables, proceed to the next step.

  6. Prepare Inner Cable for Shielded Data Cables (If Applicable)

    If working with shielded data cables, trim the inner jacket to a length of 1/8 to 3/8 inches to expose the shielded conductor bundle. Carefully remove the outer (overall) shield from the conductor bundle, ensuring not to nick or damage any inner shields. Remove any filler materials without disturbing or damaging the inner shields.

  7. Apply Sealing Compound (Choose One Method)

    Select the appropriate sealing compound based on your cable type and application. Option A: Using Liquid-Type Sealing Compound SC4-KIT-1 (Suitable for all power and shielded data cables): Pack fiber damming material tightly into all voids between conductors and the body, spreading uninsulated grounding conductor strands if applicable. Screw the sealing chamber back onto the body subassembly until it completely seats. Position the cable/fitting vertically. Mix the SC4-KIT-1 compound according to its package instructions and dispense it into the sealing chamber until the level stabilizes and fills to the top. Remove any excess compound from the outside of the sealing chamber with a damp cloth. Option B: Using Putty-Type Sealing Compound SC65 (DO NOT use for shielded cables or cables with 5 or more conductors including ground): Spread insulated conductors slightly and uninsulated grounding conductor strands if applicable. Thoroughly mix the two parts of the SC65 compound until a uniform blue color is achieved (usable life is 30 minutes at 70°F/21°C or above). Apply a small portion of compound between insulated conductors and grounding conductor strands, then bring conductors back together and apply compound all around them, forming a plug approximately equal to the sealing chamber's small inside diameter and length. Slide the sealing chamber onto the cable and compound, then screw it to the body sub-assembly until it seats completely, removing any excess compound. Fill the throat area of the sealing chamber with compound, using a suitable wooden dowel to pack it tightly around conductors. Remove any excess compound from the outside of the sealing chamber with a damp cloth.

  8. Mount Hub and Secure Assembly

    Mount the hub in the desired location. After the sealing compound has solidified (allow approximately one hour for both types), place the encapsulated assembly into the hub. Secure it in position by tightening the union until it bottoms out, ensuring metal-to-metal contact. If using putty, repack compound tightly around conductors if required and allow it to set for approximately one hour before disturbing conductors.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.