ABB Installation Products R2T35J2-N0230 Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38…
UPC: 783786668854
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Designed for 35KV outdoor applications
- Compatible with Concentric Neutral (CN) and Jacketed Concentric Neutral (JCN) cables
- Accommodates cable insulation diameters from 0.84 to 1.38 inches
- Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil conductors
- Supports stranded/compressed #1 AWG and solid/compact 1/0 AWG conductors
Specifications
Application | Cable Termination, Outdoor Application, 35kV |
Cable Type | Concentric Neutral Wire |
Color | Gray |
Conductor Size | #1 STR AWG , #1 COMPR AWG , 1/0 SOL AWG , 1/0 COMPT AWG |
Earthing | Products Includes Their Own Grounding System |
Mounting | Product Need to have Cable Holder (not included) |
Number Of Terminals | (1) Single Phase |
Special Features | Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction |
Standard | IEEE 48 |
Type | Cable Termination - Outdoor - Ranger2 |
Voltage Rating | 35 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

R2T35J4N0230
Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 230 -Stranded or Compressed #1 Compact or Solid 1/0.
R2T28M2-N0300
Outdoor Ranger2 Cable Termination. 25/28kV, Cable Type - Tape Shield/Wire Shield/UniShield. Insulation Range - .84 inch - 1.38 inch. Aluminum 2-Hole Spade #2-1250 kcmil, Conductor 350 Stranded/Compressed or 400 Compact/Solid
R2T35J4-N0240-B3
Ranger2 Termination. Type - Outdoor, 35kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0. Cable Mounting Bracket - B3 - Stainless Steel - Size 1.45 inch - 1.95 inch.
R2T35J4-N0290
Ranger2 Termination for 35KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 300 /Compact or Solid 350
R2T28M2-N2310
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 310 -Stranded or Compressed 400 Compact or Solid 500.
R2T28J4-N0410-B4
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 410 -Stranded or Compressed 1000 Compact or Solid N/A. Cable Mounting Bracket - B4 - Stainless Steel - Size 1.80 inch - 2.40inch.
R2T28M4N0300
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 300 -Stranded or Compressed 350 Compact or Solid 400.
R2T15J1-T0240-B1
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Universal Aluminum Barrel for AL or CU Condutor with Copper Wire Lead #2-4/0, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0. Cable Mounting Bracket - B1 - Stainless Steel - Size .80 inch - 1.25 inch.Frequently Asked Questions
What cable sizes are compatible with the R2T35 termination?
The R2T35 termination accommodates cable insulation diameters from 0.84 in to 2.10 in, covering #2 AWG through 1250 kcmil.
What is the minimum strike distance for the R2T35?
The minimum strike distance for the R2T35 termination is 16.8 in (427 mm).
What is the Coronal Extinction Voltage for the R2T35?
The Coronal Extinction Voltage (Partial Discharge) for the R2T35 is 30 kV (≤ 3pC).
What is the maximum design voltage to ground for R2T35?
The maximum design voltage to ground for the R2T35 termination is 22 kV.
What is the power system frequency range for R2T35?
The R2T35 termination is designed for a power system frequency range of 48 to 62 Hz.
What is the creepage distance for the R2T35 termination?
The R2T35 termination has a creepage distance of 30.0 in (762 mm).
What is the maximum altitude for R2T35 installation?
The R2T35 termination can be installed at an altitude range of up to 3300 feet max (1005 m).
What is the operating temperature range for the R2T35?
The R2T35 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).
What is the voltage rating of the R2T35 cable termination?
The R2T35 cable termination has a voltage rating of 35 kV.
What is the Lightning Impulse Withstand Voltage (BIL)?
The Lightning Impulse Withstand Voltage (BIL Dry 110 Withstand) is 200 kV Crest.
How to Install the R2T35J 35kV Ranger 2 Cable Terminator
This guide provides detailed instructions for preparing the cable, installing the lug or connector, cleaning the cable insulation, and installing the R2T35J 35kV Ranger 2 Cable Terminator for high-voltage indoor/outdoor applications on concentric and jacketed concentric neutral cables.
Estimated time: 1h 30m
Tools needed:
Wire strippers, Crimping tool, Knife or cutting tool, Vinyl tape, Gloves, Approved solvent, Aluminum oxide abrasive (grit 120 or finer, if required)
Supplies needed:
R2T35J 35kV Ranger 2 Cable Terminator Kit (includes Silicone Rubber Termination Halves, Lubricant, Grey Silicone Rubber Tape, Sealing Mastic), Compatible connector or lugs (Elastimold copper or aluminum recommended), High-voltage cable (concentric or jacketed concentric neutral), Silicone grease, Binding wire (optional, alternative to vinyl tape), Cable Support Bracket (optional)
- Perform Safety Checks and Gather Materials
DANGER: Ensure all apparatus is de-energized before beginning installation. This product must be installed by competent personnel trained in high-voltage safety practices. Check the kit contents for completeness and damage. Verify all components fit the cable and mating products. Read all instructions thoroughly and have all required tools and supplies ready, maintaining cleanliness throughout the procedure.
- Prepare the Cable for Termination
Confirm the cable size is within the kit's specified range. Train the cable into position and cut to the required length, ensuring sufficient neutral wire length for grounding. Prepare the cable according to the provided dimensions, allowing for terminal lug depth and additional conductor length for crimping. Apply the first band of mastic 1/4 inch (6mm) from the jacket end, stretching 50% and cutting flush. Bend neutral wires back, press into the mastic, and secure them 4-6 inches (100-150mm) from the cut edge with vinyl tape or binding wire. Apply a second mastic band over the neutral wires and previous mastic, then wrap two half-lapped layers of vinyl tape over the mastic seal.
- Install the Terminal Lug or Connector
If using lugs that do not fit through the termination core, clean the cable insulation and slide the termination onto the cable *before* installing the lug. Position the connector or lug and crimp it according to the manufacturer's directions, avoiding crimping the last 1/4 to 3/8 inch of the connector. After crimping, remove any excess oxide inhibitor and sharp crimp flashings.
- Clean Cable Insulation and Lug Barrel
Wipe the cable insulation with an approved solvent, taking care not to let the solvent touch the semi-con insulation shield. If using an abrasive, apply only aluminum oxide abrasive (grit 120 or finer) to the insulation, avoiding the semi-con shield. Ensure the cable insulation diameter is not reduced below the kit's allowed specifications.
- Install the First Termination Half
Create a track-resistant moisture seal by wrapping a band of gray silicone rubber tape around the base of the terminal lug. The tape band should not exceed two layers if the barrel diameter is equal to or greater than the primary insulation; otherwise, build it up to the insulation diameter. Liberally coat the edge of the semi-con insulation shield with silicone grease to fill the step. Pull the loose end of the removable core of the lower termination through the top until it is flush with the bottom. Slide the termination body onto the cable, aligning it with the forward edge of the mastic seal. Carefully remove the core by unwinding it counter-clockwise, ensuring the termination body is butted against the mastic seal without pushing or pulling the assembly.
- Install the Second Termination Half and Complete Sealing
For the second housing, pull the core down within one coil of the bottom. Slide the terminator over the cable and carefully pull the core counter-clockwise, overlapping the first terminator by 1-1/2 inches (40mm). Apply a thin film of silicone lubricant to the skirt and mastic seal area, but not to the skirt tabs. Carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal using the remaining gray silicone rubber tape, overlapping the termination insulator by approximately 1 inch and extending it over a non-crimped region of the lug/connector barrel with a half-lap configuration. Twist the concentric neutral wires together and connect them to the system ground. Finally, confirm that the High-K step does not exceed 1.5 inches.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.