ABB Installation Products R2T35J4-N0290 Ranger2 Termination for 35KV outdoor application, cable insulation diameter 1.30 - 2.10…
UPC: 783786668878
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Designed for 35 kV concentric neutral and jacketed concentric neutral cables
- Accommodates insulation diameters from 1.30 to 2.10 inches
- Includes aluminum 2-hole spade connector for #2 to 1250 kcmil conductors
- Supports stranded, compressed, compact, or solid conductor types
- Field-proven for outdoor utility and industrial applications
Specifications
Application | Cable Termination, Outdoor Application, 35kV |
Cable Type | Concentric Neutral Wire |
Color | Gray |
Conductor Size | 300 to 350 kcmil |
Connection Type | 2-Hole Spade |
Connection Type | 2-Hole Spade connector |
Earthing | Products Includes Their Own Grounding System |
Material | Aluminum |
Mounting | Product Need to have Cable Holder (not included) |
Mounting Type | Cable Mounting |
Number Of Terminals | (1) Single Phase |
Series | Ranger2 |
Size | 1.30-2.10 inches (insulation diameter) |
Size | 1.30 inch - 2.10 inch |
Special Features | Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction |
Standard | IEEE 48 |
Type | Cable Termination - Outdoor - Ranger2 |
Voltage Rating | 35 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

R2IT15M2-N0290
Ranger2 Termination for 15KV indoor application, cable insulation diameter .84 - 1.38 for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2 to 1250 kcmil. 300 kcmil stranded or 350 kcmil Solid
R2T28M2-N2310
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 310 -Stranded or Compressed 400 Compact or Solid 500.
R2T28J4-N0410-B4
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 410 -Stranded or Compressed 1000 Compact or Solid N/A. Cable Mounting Bracket - B4 - Stainless Steel - Size 1.80 inch - 2.40inch.
R2T28M4N0300
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 300 -Stranded or Compressed 350 Compact or Solid 400.
R2T15J1-T0240-B1
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Universal Aluminum Barrel for AL or CU Condutor with Copper Wire Lead #2-4/0, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0. Cable Mounting Bracket - B1 - Stainless Steel - Size .80 inch - 1.25 inch.
R2T15M2-N2300
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 300 -Stranded or Compressed 350 Compact or Solid 400.
R2T15M2-N0330
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 0.84 - 1.38 inches for Cable Type - Tape Shield/Wire Shield/ UniShield. Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 500 /Compact or Solid 600
R2T15M2-N0330-B2
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 0.84 - 1.38 inches for Cable Type - Tape Shield/Wire Shield/ UniShield. Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 500 /Compact or Solid 600, Stainless Steel Mounting Bracket 1.10 inch - 1.50 inchFrequently Asked Questions
What is the voltage rating of the R2T35 cable termination?
The R2T35 cable termination has a voltage rating of 35 kV.
What cable sizes are compatible with the R2T35 termination?
The R2T35 termination accommodates cables from #2 AWG through 1250 kcmil, with insulation diameters from 0.84 in to 2.10 in.
What is the maximum design voltage to ground for the R2T35?
The maximum design voltage to ground for the R2T35 termination is 22 kV.
What is the acceptable ambient temperature range for the R2T35?
The R2T35 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).
What type of cable insulation does the R2T35 termination accommodate?
The R2T35 termination accommodates popular XLP and EPR cable types and various shield constructions.
What is the lightning impulse withstand voltage for the R2T35?
The lightning impulse (BIL Dry 110 Withstand) voltage for the R2T35 is 200 kV Crest.
What is the minimum strike distance for the R2T35 termination?
The minimum strike distance for the R2T35 termination is 16.8 inches (427 mm).
What is the creepage distance for the R2T35 termination?
The creepage distance for the R2T35 termination is 30.0 inches (762 mm).
What is the IEEE classification for the R2T35 outdoor termination?
The IEEE classification for the R2T35 outdoor termination is Class 1A.
What power system frequency does the R2T35 support?
The R2T35 termination supports a power system frequency range of 48 to 62 Hz.
How to Install the 35kV Ranger 2 Cable Terminator (R2T35J)
This guide provides step-by-step instructions for the safe and proper installation of the 35kV Ranger 2 Cable Terminator on concentric and jacketed concentric neutral cables for indoor/outdoor applications. Ensure all safety precautions are followed.
Estimated time: 2h
Tools needed:
Approved solvent, Aluminum oxide abrasive (grit 120 or finer, if needed), Vinyl tape or binding wire, Crimping tool, Wire strippers, Measuring tape or ruler
Supplies needed:
35kV Ranger 2 Cable Terminator Kit (including Silicone Rubber Termination Halves, Lubricant, Grey Silicone Rubber Tape, Sealing Mastic, Gloves), Elastimold copper or aluminum lug/connector (or compatible), Cable (concentric or jacketed concentric neutral), System ground connection, Cable Support Bracket (optional)
- Perform Safety Checks and Prepare Workspace
DANGER: Ensure all apparatus is de-energized during installation. This product must be installed only by competent personnel trained in high voltage electrical equipment safety practices. Inspect all kit contents for completeness and damage, and verify component compatibility with the cable and mating products. Have all required tools at hand and maintain cleanliness throughout the procedure.
- Prepare the Cable
Verify the cable size fits within the kit's specified range. Train the cable into its final position and cut it to the required length, allowing sufficient neutral wire length for grounding. Prepare the cable using the specified dimensions (e.g., 13-1/2" or 13-3/4" overall, 2" or 2-1/4" semi-con, plus 'X' dimension for lug growth), accounting for the terminal lug depth. Wrap one band of sealing mastic around the cable jacket 1/4" (6mm) from the jacket end, stretching it to 50% and cutting flush without overlap. Bend the neutral wires back over the mastic, press them in, and secure them to the cable jacket 4-6" (100-150mm) from the cut edge using vinyl tape or binding wire. Apply a second mastic band over the neutral wires and previous mastic, stretching to 50% and cutting flush. Finally, wrap two half-lapped layers of vinyl tape around the mastic seal, maintaining the 1/4" (6mm) dimension.
- Install the Lug or Connector
If using a lug that will not fit through the termination core, slide the termination onto the cable before installing the lug (do not remove the core yet). Position the connector or lug and crimp it according to its directions, ensuring not to crimp the last 1/4" to 3/8" of the connector. After crimping, remove any excess oxide inhibitor and sharp crimp flashings.
- Clean Cable Insulation and Lug Barrel
Wipe the cable insulation with an approved solvent, taking care not to allow the solvent to touch the semi-con insulation shield. If abrasive cleaning is necessary, use only aluminum oxide abrasive (grit 120 or finer) on the insulation only, and do not reduce the cable insulation diameter below the kit's allowed range. Do not use abrasive on the semi-con insulation shield.
- Install the Termination Halves
Create a track-resistant moisture seal by wrapping a band of gray silicone rubber tape around the base of the terminal lug. If the barrel diameter is equal to or greater than the cable primary insulation, use no more than 2 layers. If smaller, build up the tape band to equal the insulation diameter. Apply a liberal coating of silicone grease to the edge of the semi-con insulation shield to fill the step. For the lower termination, pull the loose end of the removable core through the top until it is flush with the bottom of the termination. Slide the termination body onto the cable, aligning it with the forward edge of the mastic seal. Carefully remove the core by unwinding it counter-clockwise, starting with the loose end. Ensure the termination body, not the core, is butted up to the leading edge of the mastic seal. Do not push or pull on the termination assembly during core removal. Using the second housing, pull its core down to within one coil of the bottom. Slide this terminator over the cable and carefully pull its core counter-clockwise, overlapping the first terminator by 1-1/2" (40mm).
- Complete Sealing and Grounding
Apply a thin film of silicone lubricant to the skirt and mastic seal area, but do not lubricate the skirt tabs. Carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal using the remaining gray silicone rubber tape, overlapping the termination insulator by approximately 1" and extending the tape wrapping over a non-crimped region of the lug/connector barrel with a half-lap configuration. Twist the concentric neutral wires together and connect them securely to the system ground. Finally, confirm that the High-K step does not exceed 1.5".
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.