Authorized ABB Distributor (Installation Products)
ABB - Installation Products R2T28L4-N0410-B3 - Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Cable Type - LC Shield Tape Shield/Wire Over Tape Shield, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 1000, Cable Mounting Bracket - Stainless Steel, 1.45 inch - 1.95 inch (37-50mm)

ABB Installation Products R2T28L4-N0410-B3 Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30…

UPC: 783786584734


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 Termination (SKU: R2T28L4-N0410-B3) is engineered for 25/28KV outdoor applications, providing reliable cable termination for specific insulation diameters. This unit is designed for cables with an insulation diameter ranging from 1.30 to 2.10 inches. It is compatible with LC Shield Tape Shield and Wire Over Tape Shield cable types, ensuring a secure and effective connection. Key components included with this termination system are: * An Aluminum 2-Hole Spade connector suitable for cable sizes #2 through 1250 kcmil, accommodating both Stranded and Compressed conductors up to 1000 kcmil. This connector ensures robust electrical contact and mechanical integrity. * A Stainless Steel Cable Mounting Bracket with an adjustable range of 1.45 to 1.95 inches (37-50mm). This bracket provides secure mounting for the cable assembly in outdoor installations, resisting environmental factors. This Ranger2 termination system from ABB Installation Products is built for critical infrastructure where dependable performance is paramount. Its specific design addresses the requirements of medium-voltage outdoor power distribution systems.
  • Designed for 25/28KV outdoor applications
  • Accommodates cable insulation diameter 1.30 - 2.10 inches
  • Compatible with LC Shield Tape Shield/Wire Over Tape Shield cable types
  • Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil conductors
  • Features Stainless Steel Cable Mounting Bracket (1.45"-1.95")

Specifications

Application
Cable Termination, Outdoor Application, 28kV
Cable Type
Corrugated Shielded Wire
Color
Gray
Conductor Size
1000 kcmil
Connection Type
Spade Connector
Current Rating
1250 kcmil
Earthing
Products Includes Their Own Grounding System
Material
Aluminum, Stainless Steel
Mounting
Product Need to have Cable Holder (not included)
Mounting Type
Cable Mounting Bracket
Number Of Terminals
(1) Single Phase
Series
Ranger2
Size
1.30 - 2.10 inches (cable insulation diameter), 1.45 - 1.95 inch (37-50mm, bracket)
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Outdoor - Ranger2
Voltage Rating
28 kV
Voltage Rating
25/28 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2 to 1250 kcmil. 1000 kcmil Stranded.

R2T15J4-N0410

Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2 to 1250 kcmil. 1000 kcmil Stranded.
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 310 -Stranded or Compressed 400 Compact or Solid 500.

R2T28M2-N0310

Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 310 -Stranded or Compressed 400 Compact or Solid 500.
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 330 -Stranded or Compressed 500 Compact or Solid 600.

R2T28M2-N0330

Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 330 -Stranded or Compressed 500 Compact or Solid 600.
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 270 -Stranded or Compressed 4/0 Compact or Solid 250.

R2T28M2-N0270

Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 270 -Stranded or Compressed 4/0 Compact or Solid 250.
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 350 -Stranded or Compressed 650 Compact or Solid 750.

R2T28M4-N0350

Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 350 -Stranded or Compressed 650 Compact or Solid 750.
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 250 -Stranded or Compressed 2/0 Compact or Solid 3/0.

R2T28J4-N0250

Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 250 -Stranded or Compressed 2/0 Compact or Solid 3/0.
Outdoor, 15kV, Cable type Concentric Neutral/Jacketed Concentric Neutral, Insulation Range .64 inch to 1.12 inch, Connector Type Universal Aluminum Barrel for Aluminum or Copper Conductor with Copper Wire lead #2-4/0, Conductor Code 2/0 Stranded or Compressed 3/0 for Compact or Solid

R2T15J1-T0250

Outdoor, 15kV, Cable type Concentric Neutral/Jacketed Concentric Neutral, Insulation Range .64 inch to 1.12 inch, Connector Type Universal Aluminum Barrel for Aluminum or Copper Conductor with Copper Wire lead #2-4/0, Conductor Code 2/0 Stranded or Compressed 3/0 for Compact or Solid
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed 4/0 /Compact or Solid 250

R2T28J2-T0270

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed 4/0 /Compact or Solid 250

Frequently Asked Questions

What is the IEEE classification for the R2T28 outdoor termination?

The R2T28 outdoor termination has an IEEE Classification of Outdoor = Class 1A.

What is the creepage distance for the R2T28 termination?

The creepage distance for the R2T28 outdoor termination is 22.8 inches (579 mm).

What is the minimum strike distance for the R2T28 termination?

The minimum strike distance for the R2T28 outdoor termination is 14.5 inches (368 mm).

Where can I find installation instructions for the R2T28?

Installation instructions are provided with the kit, specifically IS-1134 for R2T28J, IS-1135 for R2T28M, and IS-1136 for R2T28L.

What is the maximum altitude for R2T28 termination installation?

The R2T28 termination can be installed at an altitude range of up to 3300 feet (1005 m) maximum.

What power system frequencies are compatible with the R2T28?

The R2T28 termination is compatible with power system frequencies ranging from 48 to 62 Hz.

What is the operating temperature range for the R2T28?

The R2T28 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).

What is the voltage rating for the R2T28 outdoor termination?

The R2T28 outdoor termination has a voltage rating of 25/28 kV. The maximum design voltage to ground is 16 kV.

What cable insulation diameters does the R2T28 termination cover?

The R2T28 termination covers cable insulation diameters from 0.84 inches (21.3 mm) to 2.10 inches (53 mm). This accommodates #2 AWG through 1250 kcmil cables.

What is the IEEE classification for the R2T28 outdoor termination?

The R2T28 outdoor termination has an IEEE Classification of Outdoor = Class 1A.

How to Install the R2T28L4 Ranger 2 Shrink Fit Silicone Rubber Termination

This guide provides step-by-step instructions for the installation of the R2T28L4 Ranger 2 Shrink Fit Silicone Rubber Termination, including cable preparation, ground braid installation, and final sealing.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Crimping tool, Solvent saturated pads, Aluminum oxide abrasive (optional)

Supplies needed:

R2T28L4 Silicone Rubber Termination kit, Preformed Ground Braid, Constant Force Spring, Grey Silicone Rubber Tape, Sealing mastic, Lubricant, Gloves, Connector (optional), Cable Support Bracket (optional), Vinyl tape

  1. Prepare the Cable

    DANGER: All apparatus must be de-energized during installation. Train the cable into position and cut it to the required length. Prepare the cable by removing the jacket, insulation, and semi-con layers according to the dimensions specified in Table 1, allowing for terminal lug depth and additional exposed conductor distance for crimping growth.

  2. Install the Ground Braid

    Carefully wrap one band of sealing mastic around the cable jacket 1/4 inch (6mm) from the jacket end. Position the preformed high-amp ground braid with the 'U' section over the metallic shield, adjacent to the jacket edge, and secure one tail over the jacket with vinyl tape, pressing the solder block into the mastic. Wrap the ground braid around the metallic shield, secure it with the constant force spring, and cinch the spring. Wrap two half-lapped layers of vinyl tape around the spring and exposed metallic shield, leaving 1 inch (25mm) of semi-con insulation exposed. Apply a second mastic strip over the solder block and previous mastic, then wrap two half-lapped layers of vinyl tape over this mastic seal and the previously applied tape to secure the ground braids.

  3. Install the Lug or Connector

    Ensure the termination assembly fits over the selected lug. If the lug will not fit through the termination core, clean the insulation and slide the termination onto the cable before installing the lug (do not remove the core at this time). Position the connector or lug and crimp it according to the manufacturer's directions, leaving the last 3/8 inch to 1/2 inch uncrimped. Remove any excess oxide inhibitor and sharp crimp flashings after crimping.

  4. Clean Cable Insulation and Lug

    Wipe the cable insulation with solvent-saturated pads, ensuring solvent does not touch the semi-con insulation shield. If abrasive must be used, apply only aluminum oxide abrasive (grit 120 or finer) on the insulation, being careful not to reduce the cable insulation diameter below that allowed by the kit.

  5. Install the Termination Body

    Create a track-resistant moisture seal by wrapping gray silicone rubber electrical tape around the base of the terminal lug, adjusting layers based on barrel diameter. Cover the edge of the semi-con insulation shield with a liberal coating of silicone grease to fill the step. For lower terminations with a fold-down skirt, pull the loose end of the removable core through the top until it is flush with the bottom of the termination. Slide the termination body onto the cable, align it with the forward edge of the mastic seal, and carefully remove the core by unwinding it counter-clockwise. Do not push or pull the termination assembly during core removal.

  6. Complete Sealing and Grounding

    Apply a thin film of silicone lubricant to the skirt and mastic seal area (avoiding skirt tabs), then carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal using the remaining gray silicone rubber electrical tape, overlapping the termination insulator by approximately 1 inch and extending over a non-crimped region of the lug/connector barrel with a half-lap configuration. Connect both ground braids to the system ground. Confirm that the High-K step does not exceed 1.5 inches.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.