ABB Installation Products R2T28M2-N0330 Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/…
UPC: 075114105033
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 25/28 kV outdoor termination for utility, industrial, and commercial power distribution
- Accommodates cable insulation diameters from 0.84" to 1.38" (#2 AWG to 1250 kcmil)
- Supports stranded/compressed 500 kcmil, solid 600 kcmil, tape/wire/unshielded cables
- Aluminum 2-hole spade connector (#2-1250 kcmil) for high-current terminations
- Six sheds, 14.5" minimum strike distance, non-tracking silicone housing for weather resistance
Specifications
Application | Cable Termination, Outdoor Application, 28kV |
Cable Type | Copper Tape Shielded Wire |
Color | Gray |
Conductor Size | 500 to 600 kcmil |
Connection Type | Aluminum 2-Hole Spade #2-1250 kcmil |
Earthing | Products Includes Their Own Grounding System |
Mounting | Product Need to have Cable Holder (not included) |
Mounting Type | Outdoor |
Number Of Terminals | (1) Single Phase |
Series | Ranger2 |
Size | 0.84 inch - 1.38 inch |
Special Features | Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction |
Standard | IEEE 48 |
Type | Cable Termination - Outdoor - Ranger2 |
Voltage Rating | 28 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

R2T28M2-N0330-B3
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Tape Shield, Wire Shield, and Unshielded Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 500 /Compact or Solid 600, Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch
R2T28M2-N0270
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 270 -Stranded or Compressed 4/0 Compact or Solid 250.
R2T28M4-N0350
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 350 -Stranded or Compressed 650 Compact or Solid 750.
R2T28J4-N0250
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 250 -Stranded or Compressed 2/0 Compact or Solid 3/0.
R2T15J1-T0250
Outdoor, 15kV, Cable type Concentric Neutral/Jacketed Concentric Neutral, Insulation Range .64 inch to 1.12 inch, Connector Type Universal Aluminum Barrel for Aluminum or Copper Conductor with Copper Wire lead #2-4/0, Conductor Code 2/0 Stranded or Compressed 3/0 for Compact or Solid
PCT1-4
15kV Single-Piece Cable Terminator (housing only), Insulation Diameter Range .640-1.070 inches
PCT2-4
25kV Single-Piece Cable Terminator (housing only), Insulation Diameter Range .830-1.180 inches
R2T28J2-T0270
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed 4/0 /Compact or Solid 250Frequently Asked Questions
What is the maximum operating voltage for this ABB Ranger2 termination?
The ABB Ranger2 Termination is rated for 28kV operation.
What insulation diameter range does the Ranger2 termination support?
This termination supports an insulation range from 0.84 inches to 1.38 inches.
What types of cables can be terminated with the R2T28M2-N0330?
The R2T28M2-N0330 is designed for tape shield, wire shield, and unshielded cable types.
What conductor sizes are compatible with the aluminum spade connector?
The aluminum 2-hole spade connector is compatible with conductors from #2 AWG to 1250 kcmil.
What specific conductor codes does this termination support?
It supports stranded or compressed 500 kcmil, or solid 600 kcmil conductors.
How to Install the R2T28M2 Shrink Fit Silicone Rubber Termination for Wire Shielded Cables
This guide provides step-by-step instructions for the safe and proper installation of the R2T28M2 shrink-fit silicone rubber termination on wire-shielded cables, including cable preparation, ground braid installation, and termination placement. Ensure all apparatus are de-energized before starting.
Estimated time: 1h 30m
Tools needed:
Cable cutter, Wire strippers, Crimping tool, Approved solvent, Aluminum oxide abrasive (grit 120 or finer), Scissors or utility knife
Supplies needed:
R2T28M2 Shrink Fit Silicone Rubber Termination kit, Silicone Lubricant, Gray Silicone Rubber Electrical Tape, Sealing Mastic, Preformed Ground Braid, Constant Force Spring, Vinyl Tape, Terminal Lug or Connector, Gloves, Oxide inhibitor (if not supplied with lug)
- Prepare the Cable
DANGER: All apparatus must be de-energized during installation. Verify the cable size fits within the insulation range specified in the Termination Selection Chart. Train the cable into position and cut it to the required length. Prepare the cable according to the specified dimensions, allowing for terminal lug depth and additional conductor distance for aluminum lug growth. Bend the leading 1-1/2 inches (38mm) of exposed shield wires back to the jacket edge.
- Install the Ground Braid
Carefully wrap one band of mastic around the cable jacket, 1/4 inch (6mm) from the jacket end, using 50% stretch. Position the preformed ground braid with the short tail over the drain wires and the solder block centered over the mastic strip. Secure the ground braid to the cable jacket with vinyl tape and press the solder block into the mastic. Apply a second mastic band over the solder block and previous mastic, maintaining the 1/4 inch (6mm) dimension. Wrap two half-lapped layers of vinyl tape around the mastic seal. Wrap the ground braid around the cable shield wires one complete wrap, trim any excess, and secure it with the constant force spring, wrapping in the same direction. Cinch the spring after the final winding and secure it with two wraps of vinyl tape.
- Install the Terminal Lug or Connector
Ensure the termination assembly fits over the selected lug. If not, clean the insulation and slide the termination onto the cable before installing the lug (do not remove the core yet). Position the connector/lug and crimp it according to the manufacturer’s directions, avoiding crimping the last 3/8 to 1/2 inch of the connector. Remove any excess oxide inhibitor and all sharp crimp flashings and edges after crimping.
- Clean Cable Insulation and Lug Barrel
Wipe the cable insulation with solvent-saturated pads, ensuring no solvent touches the semi-conductive insulation shield. If abrasive cleaning is necessary, use only aluminum oxide abrasive (grit 120 or finer) on the insulation, not the semi-conductive shield. Be careful not to reduce the cable insulation diameter below the kit's allowed range.
- Install the Termination Body
Create a track-resistant moisture seal between the termination insulator and lug/connector using gray silicone rubber electrical tape. Wrap a band of silicone tape around the base of the terminal lug, ensuring it does not exceed 2 layers if the barrel diameter is equal to or greater than the cable primary insulation, or forming a band equal to the insulation diameter if smaller. Cover the edge of the semi-conductive insulation shield with a liberal coating of silicone grease to fill the step at the semi-con cut-off. For lower terminations with a fold-down skirt, pull the loose end of the removable core through the top until it's flush with the bottom. Slide the termination body onto the cable, aligning it with the forward edge of the mastic seal. Carefully remove the core by unwinding it counter-clockwise, ensuring the termination body, not the core, is butted against the leading edge of the mastic seal. Do not push or pull the termination assembly during core removal.
- Complete Moisture Seal and Ground Connection
Apply a thin film of silicone lubricant to the skirt and mastic seal area, avoiding the skirt tabs. Carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal using the remaining gray silicone rubber electrical tape, overlapping the termination insulator by approximately 1 inch and extending the tape over a non-crimped region of the lug/connector barrel with a half-lap configuration. Connect the ground braid to the system ground. Finally, confirm that the High-K step does not exceed 1.5 inches.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.