Authorized ABB Distributor (Installation Products)
ABB - Installation Products R2T28M2-N0310 - Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 310 -Stranded or Compressed 400 Compact or Solid 500.

ABB Installation Products R2T28M2-N0310 Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/…

UPC: 075114104999


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 Termination (SKU: R2T28M2-N0310) is a 25/28 kV outdoor cable termination designed for medium-voltage power distribution systems. This termination leverages shrink-fit technology and Elastimold’s pull-down jacket seal to deliver reliable performance across a wide range of applications with minimal model variation. It accommodates cable insulation diameters from 0.84 inch (21.3 mm) to 1.38 inch (35 mm) and supports conductor types including stranded or compressed 400 kcmil, compact 500 kcmil, or solid 500 kcmil. The termination features an aluminum 2-hole spade connector (#2-1250 kcmil) for secure, low-resistance connections in outdoor environments. Key electrical ratings include a maximum design voltage to ground of 16 kV, a coronal extinction voltage of 22 kV (≤3pC), and a lightning impulse withstand (BIL Dry) of 150 kV crest. The termination withstands 10-second wet 60Hz voltage of 60 kV, 1-minute dry 60Hz voltage of 65 kV, 5-hour dry 60Hz voltage of 55 kV, and 15-minute dry DC withstand of 105 kV. The outdoor housing includes six sheds for enhanced creepage and strike distances, with a minimum strike distance of 14.5 inches (368 mm) and superior weathering characteristics from its non-tracking silicone construction. Designed for utility, industrial, and commercial power distribution systems, the Ranger2 Termination is ideal for applications in substations, switchgear, transformers, and renewable energy projects. Its compact footprint and compatibility with multiple conductor configurations make it suitable for new installations or retrofits in existing infrastructure. The field-removable center core simplifies installation, while optional insulating silicone sleeves provide additional creepage or wildlife protection when required. The termination supports popular XLP and EPR cable types and accommodates shield constructions including tape shield, wire shield, or unshielded cables.
  • 25/28 kV outdoor termination with shrink-fit housing and pull-down jacket seal
  • Accommodates insulation diameters from 0.84 inch to 1.38 inch
  • Supports stranded/compressed 400 kcmil, compact 500 kcmil, or solid 500 kcmil conductors
  • Aluminum 2-hole spade connector (#2-1250 kcmil) for secure, low-resistance connections
  • Six sheds for superior creepage and strike distances; non-tracking silicone housing
  • Field-removable center core for simplified installation
  • Optional insulating silicone sleeves for enhanced creepage or wildlife protection
  • Electrical ratings: BIL Dry 150 kV crest, 10s wet 60 kV, 1m dry 65 kV, 5h dry 55 kV, 15m DC 105 kV

Specifications

Application
Cable Termination, Outdoor Application, 28kV
Cable Type
Copper Tape Shielded Wire
Color
Gray
Conductor Size
400 to 500 kcmil
Connection Type
Aluminum 2-Hole Spade #2-1250 kcmil
Earthing
Products Includes Their Own Grounding System
Mounting
Product Need to have Cable Holder (not included)
Mounting Type
Outdoor
Number Of Terminals
(1) Single Phase
Series
Ranger2
Size
0.84 inch - 1.38 inch
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Outdoor - Ranger2
Voltage Rating
28 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Conductor 400 Stranded/Compressed or 500 Compact/Solid

R2T28J4-N0310

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Conductor 400 Stranded/Compressed or 500 Compact/Solid
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 330 -Stranded or Compressed 500 Compact or Solid 600.

R2T28M2-N0330

Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 330 -Stranded or Compressed 500 Compact or Solid 600.
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 270 -Stranded or Compressed 4/0 Compact or Solid 250.

R2T28M2-N0270

Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 270 -Stranded or Compressed 4/0 Compact or Solid 250.
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 350 -Stranded or Compressed 650 Compact or Solid 750.

R2T28M4-N0350

Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 350 -Stranded or Compressed 650 Compact or Solid 750.
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 250 -Stranded or Compressed 2/0 Compact or Solid 3/0.

R2T28J4-N0250

Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 250 -Stranded or Compressed 2/0 Compact or Solid 3/0.
Outdoor, 15kV, Cable type Concentric Neutral/Jacketed Concentric Neutral, Insulation Range .64 inch to 1.12 inch, Connector Type Universal Aluminum Barrel for Aluminum or Copper Conductor with Copper Wire lead #2-4/0, Conductor Code 2/0 Stranded or Compressed 3/0 for Compact or Solid

R2T15J1-T0250

Outdoor, 15kV, Cable type Concentric Neutral/Jacketed Concentric Neutral, Insulation Range .64 inch to 1.12 inch, Connector Type Universal Aluminum Barrel for Aluminum or Copper Conductor with Copper Wire lead #2-4/0, Conductor Code 2/0 Stranded or Compressed 3/0 for Compact or Solid
15kV Single-Piece Cable Terminator (housing only), Insulation Diameter Range .640-1.070 inches

PCT1-4

15kV Single-Piece Cable Terminator (housing only), Insulation Diameter Range .640-1.070 inches
25kV Single-Piece Cable Terminator (housing only), Insulation Diameter Range .830-1.180 inches

PCT2-4

25kV Single-Piece Cable Terminator (housing only), Insulation Diameter Range .830-1.180 inches

Frequently Asked Questions

Is this termination suitable for outdoor use?

Yes, the Ranger2 Termination is designed for outdoor applications.

What voltage rating does this termination have?

The termination is rated for 28kV systems.

What cable insulation diameters does this termination support?

The Ranger2 Termination supports insulation diameters from 0.84 inch to 1.38 inch.

What conductor types are compatible with this termination?

It supports stranded or compressed 400 kcmil, compact 500 kcmil, or solid 500 kcmil conductors.

What connector type is used in this termination?

The termination uses an aluminum 2-hole spade connector rated #2-1250 kcmil.

Can this termination be used with shielded cables?

Yes, it supports tape shield, wire shield, and unshielded cables.

How to Install the R2T28M2 Shrink Fit Silicone Rubber Termination for Tape Shielded Cables

This guide provides step-by-step instructions for the safe and correct installation of the R2T28M2 28kV Ranger 2 Shrink Fit Silicone Rubber Termination on tape shielded cables, including cable preparation, ground braid installation, lug connection, and termination placement. Ensure all apparatus is de-energized before starting.

Estimated time: 1h 30m

Tools needed:

Cable preparation tools (knife, wire strippers), Crimping tool, Measuring tape/ruler, Approved solvent, Aluminum oxide abrasive (grit 120 or finer)

Supplies needed:

R2T28M2 Silicone Rubber Termination kit (includes termination, lubricant, gray silicone rubber tape, constant force spring, preformed ground braid, sealing mastic, copper foil tape, gloves), Terminal lug/connector (appropriate for cable), Vinyl electrical tape

  1. Prepare the Cable

    DANGER: All apparatus must be de-energized during installation. First, check that the cable size fits within the insulation range specified in the Termination Selection Chart. Train the cable into position and cut it to the required length. Prepare the cable by removing the jacket and semi-conductive layer according to the dimensions provided in Table 1 and allowing for terminal lug depth plus growth allowance. Secure the edge of the tape shield with a single wrap of the supplied copper foil tape to prevent unrolling.

  2. Install the Ground Braid

    Carefully wrap one band of mastic around the cable jacket 1/4 inch (6mm) from the jacket end, using 50% stretch and cutting flush without overlap. Position the preformed ground braid with its short tail over the tape shield and the solder block centered over the mastic strip. Secure the ground braid to the cable jacket using vinyl tape and press the solder block firmly into the mastic. Apply a second mastic band over the solder block and previous mastic, maintaining the 1/4 inch (6mm) dimension. Wrap two half-lapped layers of vinyl tape around the mastic seal. Finally, wrap the ground braid around the cable tape shield one complete wrap, trim any excess to prevent overlap, and secure it in place with the constant force spring, wrapping the spring in the same direction as the braid. Cinch the spring after the final winding and secure it with two wraps of vinyl tape.

  3. Install the Lug or Connector

    Before proceeding, check to ensure the termination assembly will fit over the selected lug. If it does not, clean the insulation and slide the termination onto the cable before installing the lug (do not remove the core at this stage). Position the connector or lug and crimp it according to the manufacturer’s directions, ensuring not to crimp the last 3/8 to 1/2 inch of the connector. After crimping, remove any excess oxide inhibitor and all sharp crimp flashings and edges.

  4. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation thoroughly with an approved solvent, being careful not to allow the solvent to touch the semi-conductive insulation shield. If abrasive cleaning is necessary, use only aluminum oxide abrasive (grit 120 or finer) on the insulation, never on the semi-conductive shield. Exercise caution to avoid reducing the cable insulation diameter below the kit's allowed specifications.

  5. Install the Termination Body

    Create a track-resistant moisture seal between the termination insulator and the lug/connector by wrapping a band of the supplied gray silicone rubber electrical tape around the base of the terminal lug. The number of layers depends on the barrel diameter relative to the cable primary insulation. Liberally coat the edge of the semi-conductive insulation shield with silicone grease to fill the step. For terminations with a fold-down skirt, pull the loose end of the removable core through the top until it is flush with the bottom of the termination. Slide the termination body onto the cable, aligning it with the forward edge of the mastic seal. Carefully remove the core by unwinding it counter-clockwise, starting with the loose end. Ensure the termination body, not the core, is butted against the leading edge of the mastic seal. Continue removing the core without pushing or pulling on the termination assembly.

  6. Complete Sealing and Grounding

    Apply a thin film of silicone lubricant to the skirt and mastic seal area, but avoid lubricating the skirt tabs. Carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal using the remaining gray silicone rubber electrical tape, overlapping the termination insulator by approximately 1 inch and extending the tape wrapping over a non-crimped region of the lug/connector barrel with a half-lap configuration. Connect the ground braid securely to the system ground. Finally, confirm that the High-K step does not exceed 1.5 inches.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.