ABB - Installation Products R2T28M4-N0350 - Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 350 -Stranded or Compressed 650 Compact or Solid 750.

ABB Installation Products R2T28M4-N0350 Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/…

UPC: 075114105057


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 Termination, SKU R2T28M4-N0350, is an outdoor-rated termination designed for 28kV applications. This unit is compatible with tape shield, wire shield, and unshielded cable types. Its insulation range accommodates cable diameters from 1.30 inches to 2.10 inches, ensuring a secure fit for a variety of cable constructions. The integrated connector is a two-hole aluminum spade, suitable for conductors ranging from #2 AWG to 1250 kcmil. Specifically, it supports stranded or compressed conductors up to 350 kcmil, compact conductors up to 650 kcmil, and solid conductors up to 750 kcmil. This termination provides a reliable connection point for power distribution systems operating at 28kV. Its outdoor rating signifies suitability for exposed installations. The robust construction and specific conductor size compatibility make it a functional component for electrical infrastructure projects requiring dependable cable terminations. Manufacturer: ABB - Installation Products. UNSPSC Code: 26121648.
  • Outdoor-rated 28kV termination for electrical power systems.
  • Accommodates tape shield, wire shield, and unshielded cable types.
  • Insulation range: 1.30 inch - 2.10 inch.
  • Aluminum 2-hole spade connector for conductors #2 - 1250 kcmil.
  • Supports 350 kcmil (stranded/compressed), 650 kcmil (compact), 750 kcmil (solid) conductors.

Specifications

Application
Cable Termination, Outdoor Application, 28kV
Cable Type
Copper Tape Shielded Wire
Color
Gray
Conductor Size
650 to 750 kcmil
Earthing
Products Includes Their Own Grounding System
Mounting
Product Need to have Cable Holder (not included)
Number Of Terminals
(1) Single Phase
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Outdoor - Ranger2
Voltage Rating
28 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 650 /Compact or Solid 750

R2T35M4N0350

Ranger2 Termination for 35KV outdoor application, cable insulation diameter .84 - 1.38 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 650 /Compact or Solid 750
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 250 -Stranded or Compressed 2/0 Compact or Solid 3/0.

R2T28J4-N0250

Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 250 -Stranded or Compressed 2/0 Compact or Solid 3/0.
Outdoor, 15kV, Cable type Concentric Neutral/Jacketed Concentric Neutral, Insulation Range .64 inch to 1.12 inch, Connector Type Universal Aluminum Barrel for Aluminum or Copper Conductor with Copper Wire lead #2-4/0, Conductor Code 2/0 Stranded or Compressed 3/0 for Compact or Solid

R2T15J1-T0250

Outdoor, 15kV, Cable type Concentric Neutral/Jacketed Concentric Neutral, Insulation Range .64 inch to 1.12 inch, Connector Type Universal Aluminum Barrel for Aluminum or Copper Conductor with Copper Wire lead #2-4/0, Conductor Code 2/0 Stranded or Compressed 3/0 for Compact or Solid
15kV Single-Piece Cable Terminator (housing only), Insulation Diameter Range .640-1.070 inches

PCT1-4

15kV Single-Piece Cable Terminator (housing only), Insulation Diameter Range .640-1.070 inches
25kV Single-Piece Cable Terminator (housing only), Insulation Diameter Range .830-1.180 inches

PCT2-4

25kV Single-Piece Cable Terminator (housing only), Insulation Diameter Range .830-1.180 inches
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed 4/0 /Compact or Solid 250

R2T28J2-T0270

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed 4/0 /Compact or Solid 250
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Tape Shield, Wire Shield, and Unshielded Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 500 /Compact or Solid 600, Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch

R2T28M2-N0330-B3

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Tape Shield, Wire Shield, and Unshielded Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 500 /Compact or Solid 600, Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 500 /Compact or Solid 600, Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch

R2T28J2-N0330-B3

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 500 /Compact or Solid 600, Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch

Frequently Asked Questions

Where can I find installation instructions for R2T28?

Installation instructions are available under IS-1134 for R2T28J, IS-1135 for R2T28M, and IS-1136 for R2T28L.

What power system frequency is compatible with R2T28?

The R2T28 termination is compatible with a power system frequency range of 48 to 62 Hz.

What is the maximum altitude for R2T28 installation?

The R2T28 termination can be installed at a maximum altitude of 3300 feet (1005 m).

What is the operating temperature range for R2T28?

The R2T28 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).

What are the strike and creepage distances?

The minimum strike distance is 14.5 in (368 mm), and the creepage distance is 22.8 in (579 mm).

What is the lightning impulse withstand voltage?

The lightning impulse withstand voltage (BIL Dry 110 Withstand) for the R2T28 termination is 150 kV Crest.

What is the voltage rating of the R2T28 termination?

The R2T28 termination has a voltage rating of 25/28 kV. The maximum design voltage to ground is 16 kV.

What type of cable insulation is compatible with R2T28?

The R2T28 termination accommodates popular XLP and EPR cable types and shield constructions.

What cable sizes does the R2T28 termination support?

The R2T28 termination supports cable insulation diameters from 0.84 in (21.3 mm) to 2.10 in (53 mm), covering #2 AWG through 1250 kcmil.

Where can I find installation instructions for R2T28?

Installation instructions are available under IS-1134 for R2T28J, IS-1135 for R2T28M, and IS-1136 for R2T28L.

How to Install the R2T28M4-N0350 Shrink Fit Silicone Rubber Termination

This guide provides detailed instructions for the safe and proper installation of the R2T28M4-N0350 Shrink Fit Silicone Rubber Termination for tape shielded cables, covering cable preparation, ground braid installation, lug connection, and termination application.

Estimated time: 1h 30m

Tools needed:

Crimping tool, Soldering iron, Wire strippers, Cable knife, Measuring tape or ruler, Safety glasses

Supplies needed:

R2T28M4-N0350 Silicone Rubber Termination kit, Silicone lubricant (grease), Gray silicone rubber electrical tape, Constant force spring, Preformed ground braid, Sealing mastic, Copper foil tape, Gloves, Vinyl tape, Terminal lug or connector, Approved solvent, Aluminum oxide abrasive (grit 120 or finer)

  1. Ensure Safety and Prepare for Installation

    DANGER: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products. Verify the R2T28M4-N0350 kit contents are complete and undamaged. Confirm all components fit the cable and mating products. Read all instructions thoroughly and have all required tools and supplies ready, maintaining cleanliness throughout the procedure.

  2. Prepare the Cable

    Check that the cable size fits within the termination range. Train the cable into position and cut it to the required length. Prepare the cable using the dimensions specified in Table 1 for jacket removal length, allowing for terminal lug depth and growth allowance. Ensure 1 inch (25mm) of tape shield and insulation are exposed. Prevent the tape shield from unrolling by securing its edge with a single wrap of the supplied copper foil tape.

  3. Install the Ground Braid

    Wrap one band of mastic around the cable jacket 1/4 inch (6mm) from the jacket end, using 50% stretch, and cut flush. Position the preformed ground braid with the short tail over the tape shield and the solder block centered over the mastic strip. Secure the ground braid to the cable jacket with vinyl tape and press the solder block into the mastic. Apply a second mastic band over the solder block and previous mastic, maintaining the 1/4 inch (6mm) dimension, and cut flush. Wrap two half-lapped layers of vinyl tape around the mastic seal. Wrap the ground braid around the cable tape shield one complete wrap, trim any excess, and secure it in place with the constant force spring, wrapping in the same direction as the ground braid. Cinch the spring after the final winding and secure it with two wraps of vinyl tape.

  4. Install the Terminal Lug or Connector

    Verify that the termination assembly fits over the selected lug. If it does not, clean the insulation and slide the termination onto the cable before installing the lug, but do not remove the core at this time. Position the connector or lug and crimp it according to the manufacturer’s directions, avoiding crimping the last 3/8 to 1/2 inch of the connector. Remove any excess oxide inhibitor and all sharp crimp flashings and edges after crimping.

  5. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation with an approved solvent, ensuring the solvent does not touch the semi-conductive insulation shield. If abrasive cleaning is necessary, use only aluminum oxide abrasive (grit 120 or finer) on the insulation only, never on the semi-conductive shield. Be careful not to reduce the cable insulation diameter below the kit's allowed specifications.

  6. Install the Termination Body

    Create a track-resistant moisture seal between the termination insulator and the lug/connector by wrapping a band of gray silicone rubber electrical tape around the base of the terminal lug. If the barrel diameter is equal to or greater than the cable primary insulation, use no more than two layers. If smaller, build up the tape band to equal the insulation diameter. Liberally coat the edge of the semi-conductive insulation shield with silicone grease to fill the step at the cut-off. For lower terminations with a fold-down skirt, pull the loose end of the removable core through the top until it is flush with the bottom of the termination. Slide the termination body onto the cable, aligning it with the forward edge of the mastic seal. Carefully remove the core by unwinding it counter-clockwise, starting with the loose end. Ensure the termination body, not the core, is butted against the leading edge of the mastic seal. Do not push or pull the termination assembly during core removal.

  7. Complete Moisture Seal and Ground Connection

    Apply a thin film of silicone lubricant to the skirt and mastic seal area, but avoid lubricating the skirt tabs. Carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal using the remaining gray silicone rubber electrical tape, overlapping the termination insulator by approximately 1 inch and extending the tape wrapping over a non-crimped region of the lug/connector barrel with a half-lap configuration. Finally, connect the ground braid to the system ground and confirm that the High-K step does not exceed 1.5 inches.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.