ABB Installation Products R2T28J4-N0310 Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30…
UPC: 783786535897
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Voltage rating: 25/28 kV with max design voltage to ground of 16 kV
- Insulation diameter range: 1.30-2.10 inches for CN and JCN cables
- Conductor compatibility: #2 AWG to 1250 kcmil (400 kcmil stranded/compressed or 500 kcmil compact/solid)
- Connection type: Aluminum 2-hole spade connector for secure, high-conductivity joints
- Housing features: Non-tracking silicone with six sheds for superior creepage and strike distances
- Installation benefits: Field-removable center core, pull-down jacket seal, and compact design for restricted spaces
- Optional accessories: Insulating silicone sleeves for enhanced creepage or wildlife protection
Specifications
Application | Cable Termination, Outdoor Application, 28kV |
Cable Type | Concentric Neutral Wire |
Color | Gray |
Conductor Size | 400 to 500 kcmil |
Earthing | Products Includes Their Own Grounding System |
Mounting | Product Need to have Cable Holder (not included) |
Number Of Terminals | (1) Single Phase |
Special Features | Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction |
Standard | IEEE 48 |
Type | Cable Termination - Outdoor - Ranger2 |
Voltage Rating | 28 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

R2T28M2-N2310
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Copper 2-Hole Spade #2-1250 kcmil, Conductor Code - 310 -Stranded or Compressed 400 Compact or Solid 500.
R2T28J2-N0220
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed #2 /Compact or Solid #1
R2T28L4-N0410
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Cable Type - LC Shield Tape Shield/Wire Over Tape Shield, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 1000
R2T28J4-N0410
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 1000.
R2T15J1T0210B1
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Compact or Solid #2. Stainless Steel Mounting Bracket .80 inch - 1.25 inch (20-32mm)
R2T15M4N0440
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 440 -Stranded or Compressed 1250 Compact or Solid N/A.
R2T28J4-H0270-B3
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 270 -Stranded or Compressed 4/0 Compact or Solid 250. Cable Mounting Bracket - B3 - Stainless Steel - Size 1.45 inch - 1.95 inch.
R2T28L4-N0410-B3
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Cable Type - LC Shield Tape Shield/Wire Over Tape Shield, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 1000, Cable Mounting Bracket - Stainless Steel, 1.45 inch - 1.95 inch (37-50mm)Frequently Asked Questions
What is the voltage rating for this Ranger2 termination?
The ABB Ranger2 termination is rated for 25/28 kV applications.
What cable insulation diameters does this termination support?
This termination supports cable insulation diameters ranging from 1.30 to 2.10 inches.
What conductor sizes are compatible with the included spade connector?
The included Aluminum 2-Hole Spade connector is compatible with conductor sizes from #2 AWG up to 1250 kcmil.
What types of 400/500 kcmil conductors can be used?
This termination is suitable for 400 kcmil stranded/compressed or 500 kcmil compact/solid conductors.
What type of neutral cable is this termination for?
This termination is designed for Concentric Neutral (CN) and Jacketed Concentric Neutral (JCN) cables.
Is this termination suitable for indoor use?
No, this ABB Ranger2 termination is specifically designed for outdoor applications.
How to Install the R2T28J4 Ranger 2 Cable Termination
This guide provides step-by-step instructions for installing the 15kV & 28kV Ranger 2 Cable Termination on concentric and jacketed concentric neutral cables for indoor/outdoor applications. It covers cable preparation, lug installation, cleaning, and termination assembly.
Estimated time: 1h 30m
Tools needed:
Crimping tool, Wire strippers, Cable cutting tool, Measuring tape
Supplies needed:
R2T28J4 Silicone Rubber Termination, Silicone Lubricant, Grey Silicone Rubber Tape, Sealing Mastic, Gloves, Electrical Connector/Lug, Vinyl tape or binding wire, Approved solvent, Aluminum oxide abrasive (optional), Silicone grease
- De-energize Apparatus and Inspect Components
DANGER: Ensure all apparatus is de-energized during installation or removal of parts. Inspect all parts for damage, proper rating, and compatibility with mating parts. Verify that the kit contents are complete and undamaged, and that all components fit properly with the cable and/or mating products. Read all instructions thoroughly before beginning.
- Prepare the Cable
Train the cable into position and cut it to the required length for installation, ensuring sufficient neutral wire length for the grounding connection. Prepare the cable using the dimensions provided in the instructions, allowing for the depth of the terminal lug and additional exposed conductor distance for crimping. Apply the first band of sealing mastic around the cable jacket 1/4 inch (6mm) from the jacket end, using 50% stretch, and cut it flush without overlap. Bend the neutral wires back over and press them into the sealing mastic, then secure them to the cable jacket 4-6 inches (100-150mm) from the cut edge using vinyl tape or binding wire. Apply a second mastic band over the neutral wires and the previously applied mastic, using 50% stretch, and cut it flush without overlap. Wrap two half-lapped layers of vinyl tape around the mastic seal, carefully maintaining the 1/4 inch (6mm) dimension.
- Install the Lug or Connector
If using a lug that will not fit through the termination core, clean the insulation and slide the termination onto the cable before installing the lug (do not remove the core at this time). Position the connector/lug and crimp it according to the manufacturer's directions, ensuring not to crimp the last 1/4 inch to 3/8 inch of the connector. Remove any excess oxide inhibitor and sharp crimp flashings after crimping.
- Clean Cable Insulation and Lug Barrel
Wipe the cable insulation with an approved solvent. Do not allow the solvent to touch the semi-con insulation shield. If abrasive must be used, apply it only on the insulation (not the semi-con shield), use aluminum oxide abrasive (grit 120 or finer), and be careful not to reduce the cable insulation diameter below that allowed by the kit.
- Install the Termination Body
Create a track-resistant moisture seal by wrapping a band of gray silicone rubber tape around the base of the terminal lug. Adjust the number of layers based on whether the barrel diameter is equal to or smaller than the cable primary insulation. Cover the edge of the semi-con insulation shield with a liberal coating of silicone grease to fill the step at the semi-con cut off. For lower terminations with a fold-down skirt, pull the loose end of the removable core through the top of the termination until the core is flush with the bottom. Slide the termination body onto the cable, aligning it with the forward edge of the mastic seal. Carefully remove the core by unwinding it counter-clockwise, starting with the loose end, ensuring the termination body (not the core) is butted up to the leading edge of the mastic seal. Do not push or pull on the termination assembly during core removal.
- Complete Termination Sealing and Grounding
Apply a thin film of silicone lubricant to the skirt and mastic seal area (do not lubricate skirt tabs). Carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal using the remaining gray silicone rubber tape, overlapping the termination insulator by approximately 1 inch and extending over a non-crimped region of the lug/connector barrel with a half-lap configuration. Twist the concentric neutral wires together and connect them to the system ground. Confirm that the High-K step does not exceed 1.5 inches.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.