Authorized ABB Distributor (Installation Products)
ABB - Installation Products R2T28J4-H0270-B3 - Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 1-Hole Spade #2-500 kcmil, Conductor Code - 270 -Stranded or Compressed 4/0 Compact or Solid 250. Cable Mounting Bracket - B3 - Stainless Steel - Size 1.45 inch - 1.95 inch.

ABB Installation Products R2T28J4-H0270-B3 Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Concentric Neutral/Jacketed…

UPC: 783786534937


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 Termination, SKU R2T28J4-H0270-B3, is a robust outdoor termination designed for 28kV applications. This unit is specifically engineered for concentric neutral and jacketed concentric neutral cable types, accommodating insulation diameters ranging from 1.30 inches to 2.10 inches. The termination features a high-quality aluminum 1-hole spade connector, compatible with conductor sizes from #2 AWG to 500 kcmil. It supports conductor codes 270, which includes stranded or compressed 4/0 AWG compact or solid 250 kcmil conductors. For secure and reliable mounting, the Ranger2 Termination includes a B3 stainless steel cable mounting bracket. This bracket is sized to fit cables with diameters between 1.45 inches and 1.95 inches, ensuring a stable installation in outdoor environments. The Ranger2 series from ABB Installation Products is known for its dependable performance in power distribution systems. This specific model offers a reliable connection point for medium-voltage cables, ensuring electrical integrity and safety. Its construction materials, aluminum for the connector and stainless steel for the bracket, are chosen for their corrosion resistance and durability in outdoor conditions. The precise insulation range and conductor size compatibility make it a versatile option for various utility and industrial power infrastructure projects. The 28kV voltage rating signifies its suitability for medium-voltage networks. The 1-hole spade connector provides a secure mechanical and electrical connection point for downstream equipment or splices. The inclusion of the mounting bracket simplifies installation and ensures proper cable support, reducing strain on the termination itself. This product is a key component for maintaining the reliability of outdoor power distribution networks.
  • 28kV Voltage Rating for Medium Voltage Applications
  • Accommodates 1.30" - 2.10" Insulation Diameter
  • Aluminum 1-Hole Spade Connector (#2 - 500 kcmil)
  • Compatible with Concentric Neutral/Jacketed Concentric Neutral Cables
  • Includes Stainless Steel Mounting Bracket (1.45" - 1.95" Cable Size)

Specifications

Application
Cable Termination, Outdoor Application, 28kV
Cable Type
Concentric Neutral Wire
Color
Gray
Conductor Size
4/0 AWG , 250 kcmil
Earthing
Products Includes Their Own Grounding System
Mounting
Product Need to have Cable Holder (not included)
Number Of Terminals
(1) Single Phase
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Outdoor - Ranger2
Voltage Rating
28 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 270 -Stranded or Compressed 4/0 Compact or Solid 250.

R2T28M2-N0270

Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 270 -Stranded or Compressed 4/0 Compact or Solid 250.
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Cable Type - LC Shield Tape Shield/Wire Over Tape Shield, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 1000, Cable Mounting Bracket - Stainless Steel, 1.45 inch - 1.95 inch (37-50mm)

R2T28L4-N0410-B3

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Cable Type - LC Shield Tape Shield/Wire Over Tape Shield, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 1000, Cable Mounting Bracket - Stainless Steel, 1.45 inch - 1.95 inch (37-50mm)
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 310 -Stranded or Compressed 400 Compact or Solid 500.

R2T28M2-N0310

Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 310 -Stranded or Compressed 400 Compact or Solid 500.
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 330 -Stranded or Compressed 500 Compact or Solid 600.

R2T28M2-N0330

Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - .84 inch - 1.38 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 330 -Stranded or Compressed 500 Compact or Solid 600.
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 350 -Stranded or Compressed 650 Compact or Solid 750.

R2T28M4-N0350

Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Tape Shield/Wire Shield/ Unshield, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 350 -Stranded or Compressed 650 Compact or Solid 750.
Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 250 -Stranded or Compressed 2/0 Compact or Solid 3/0.

R2T28J4-N0250

Ranger2 Termination. Type - Outdoor, 28kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - 1.30 inch - 2.10 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 250 -Stranded or Compressed 2/0 Compact or Solid 3/0.
Outdoor, 15kV, Cable type Concentric Neutral/Jacketed Concentric Neutral, Insulation Range .64 inch to 1.12 inch, Connector Type Universal Aluminum Barrel for Aluminum or Copper Conductor with Copper Wire lead #2-4/0, Conductor Code 2/0 Stranded or Compressed 3/0 for Compact or Solid

R2T15J1-T0250

Outdoor, 15kV, Cable type Concentric Neutral/Jacketed Concentric Neutral, Insulation Range .64 inch to 1.12 inch, Connector Type Universal Aluminum Barrel for Aluminum or Copper Conductor with Copper Wire lead #2-4/0, Conductor Code 2/0 Stranded or Compressed 3/0 for Compact or Solid
Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed 4/0 /Compact or Solid 250

R2T28J2-T0270

Ranger2 Termination for 25/28KV outdoor application, cable insulation diameter .84 - 1.38 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Universal Aluminum Barrel For Aluminum or Copper Conductor with copper wire lead #2-4/0, Stranded or Compressed 4/0 /Compact or Solid 250

Frequently Asked Questions

What is the maximum voltage rating for this Ranger2 termination?

The ABB Ranger2 termination has a voltage rating of 28kV, suitable for medium voltage applications.

What cable insulation diameters does this termination support?

This termination supports cable insulation diameters ranging from 1.30 inches to 2.10 inches.

What type of connector is included with this termination?

The termination includes an aluminum 1-hole spade connector, compatible with conductor sizes from #2 AWG to 500 kcmil.

What cable mounting bracket is supplied with this unit?

A B3 stainless steel cable mounting bracket is included, designed for cable sizes between 1.45 inches and 1.95 inches.

What cable types is this Ranger2 termination designed for?

This termination is designed for concentric neutral and jacketed concentric neutral cable types.

How to Install the 28kV Ranger 2 Cable Termination (R2T28J4)

This guide provides step-by-step instructions for the installation of the 28kV Ranger 2 Cable Termination (R2T28J4) on concentric and jacketed concentric neutral cables for indoor/outdoor applications. DANGER: All apparatus must be de-energized during installation. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Crimping tool, Measuring tape or ruler, Approved solvent, Aluminum oxide abrasive (grit 120 or finer), Vinyl tape, Binding wire

Supplies needed:

Silicone Rubber Termination, Silicone Lubricant, Grey Silicone Rubber Tape, Sealing Mastic, Gloves, Elastimold copper or aluminum lugs (or compatible), Silicone grease, Cable Support Bracket (optional)

  1. Verify Cable Compatibility

    Check to ensure the cable size fits within the kit's specified range as shown in the Termination Selection Chart. Failure to use compatible components may result in product failure.

  2. Cut Cable to Length

    Train the cable into its final position and cut it to the length required for the installation. Allow sufficient neutral wire length for the grounding connection.

  3. Prepare Cable Dimensions

    Prepare the cable using the dimensions shown in the instructions, allowing for the depth of the terminal lug. Provide additional exposed conductor distance to account for growth during crimping of aluminum lugs or connectors, as specified by the 'X' dimension for your cable size.

  4. Apply First Mastic Band

    Using 50% stretch, carefully wrap one band of sealing mastic around the cable jacket 1/4 inch (6mm) from the jacket end. Position the mastic carefully as it also serves as a marker for positioning the terminator. Cut the mastic flush; do not overlap.

  5. Secure Neutral Wires

    Bend the neutral wires back over the mastic and press them into the sealing mastic. Secure the neutral wires to the cable jacket 4-6 inches (100-150mm) from the cut edge using vinyl tape or binding wire.

  6. Apply Second Mastic Band

    Using 50% stretch, apply a second mastic band over the neutral wires and the previously applied mastic. Cut the mastic flush; do not overlap.

  7. Seal Mastic with Tape

    Wrap two half-lapped layers of vinyl tape around the mastic seal, carefully maintaining the 1/4 inch (6mm) dimension from the jacket end.

  8. Prepare for Lug Installation (if needed)

    If using lugs other than Elastimold copper or aluminum lugs that will not fit through the termination core, clean the insulation and slide the termination onto the cable before installing the lug. Do not remove the core at this time.

  9. Crimp Lug or Connector

    Position the connector or lug and crimp it according to its specific directions. Do not crimp the last 1/4 inch to 3/8 inch of the connector. After crimping, remove any excess oxide inhibitor and sharp crimp flashings.

  10. Clean Cable Insulation

    Wipe the cable insulation with an approved solvent. IMPORTANT: Do not allow the solvent to touch the semi-con insulation shield.

  11. Abrasive Cleaning (if needed)

    If abrasive cleaning is necessary, use it only on the insulation. Do not use abrasive on the semi-con insulation shield. Use only aluminum oxide abrasive, grit 120 or finer, and be careful not to reduce the cable insulation diameter below that allowed by the kit.

  12. Create Moisture Seal at Lug Base

    Wrap a band of gray silicone rubber tape (contained in the kit) around the base of the terminal lug to create a track-resistant moisture seal. If the barrel diameter is equal to or greater than the cable primary insulation, the tape band should not exceed 2 layers. If the barrel diameter is smaller, use the tape strip to form the tape band equal to the insulation diameter.

  13. Apply Silicone Grease to Semi-Con Edge

    Cover the edge of the semi-con insulation shield with a liberal coating of silicone grease. This silicone grease is crucial for filling the step at the semi-con cut-off.

  14. Prepare Termination Core (if applicable)

    On lower terminations with a fold-down skirt, pull the loose end of the removable core through the top of the termination until the core is flush with the bottom of the termination.

  15. Slide and Unwind Termination

    Slide the termination body onto the cable, aligning the terminator with the forward edge of the mastic seal. Carefully begin to remove the core by unwinding it counter-clockwise, starting with the loose end. Ensure the termination body, not the core, is butted up to the leading edge of the mastic seal. Do not push or pull on the termination assembly while removing the core material.

  16. Fold Down Skirt

    Apply a thin film of silicone lubricant to the skirt and mastic seal area, but do not lubricate the skirt tabs. Carefully fold down the skirt over the mastic seal.

  17. Complete Lug Area Moisture Seal

    With the termination installed, complete the lug area moisture seal using the remaining gray silicone rubber tape. Overlap the termination insulator by approximately 1 inch and extend the tape wrapping over a non-crimped region of the lug/connector barrel with a half-lap configuration.

  18. Connect to System Ground

    Twist the concentric neutral wires together and connect them securely to the system ground.

  19. Confirm High-K Step

    Confirm that the High-K step, which should overlap the cable semi-con, does not exceed 1.5 inches.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.