Authorized ABB Distributor (Installation Products)
ABB - Installation Products R2T15J4N0410-B3 - Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 1000. Stainless Steel Mounting Bracket 1.45 inch - 1.95 inch (37-50mm)

ABB Installation Products R2T15J4N0410-B3 Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10…

UPC: 783786044993


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Ranger2 Termination (SKU: R2T15J4N0410-B3) is a field-proven outdoor termination solution for 15KV concentric neutral and jacketed concentric neutral cables with insulation diameters between 1.30 and 2.10 inches. This termination kit includes an aluminum 2-hole spade connector rated for #2 to 1250 kcmil stranded or compressed conductors, ensuring compatibility with a wide range of cable sizes used in medium-voltage distribution systems. The termination features a corrosion-resistant stainless steel mounting bracket with an adjustable range of 1.45 to 1.95 inches (37-50mm), allowing secure installation on utility poles, transformers, or switchgear. Designed for outdoor environments, it meets the mechanical and electrical demands of overhead distribution networks, providing reliable insulation and stress control for long-term operation. Key applications include utility substations, overhead distribution lines, and industrial power systems requiring 15KV-rated terminations. The Ranger2 system simplifies installation with pre-engineered components, reducing field assembly time while maintaining compliance with industry standards for medium-voltage cable terminations.
  • Terminates 15KV concentric neutral and jacketed concentric neutral cables
  • Supports cable insulation diameters from 1.30 to 2.10 inches
  • Includes aluminum 2-hole spade connector for #2 to 1250 kcmil stranded/compressed conductors
  • Stainless steel mounting bracket adjusts from 1.45 to 1.95 inches (37-50mm)
  • Field-proven solution for outdoor medium-voltage distribution systems

Specifications

Application
Cable Termination, Outdoor Application, 15kV
Cable Type
Concentric Neutral Wire
Color
Gray
Conductor Size
1000 kcmil
Connection Type
2-Hole Spade connector
Current Rating
1250 A
Earthing
Products Includes Their Own Grounding System
Material
Aluminum, Stainless Steel
Mounting
Product Need to have Cable Holder (not included)
Mounting Type
Stainless Steel Mounting Bracket (1.45-1.95 inch adjustable)
Number Of Terminals
(1) Single Phase
Series
Ranger2
Size
1.30-2.10 inches (insulation diameter), #2-1250 kcmil (conductor size)
Special Features
Silicone Rubber Housing. Lightweight, Compact Design. Pull-Down Tabs for Easy Installation. Thick Wall Construction
Standard
IEEE 48
Type
Cable Termination - Outdoor - Ranger2
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for LC Shield Tape Shield/Wire Over Tape Shield. includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 1000.

R2T15L4-N0410

Ranger2 Termination for 15KV outdoor application, cable insulation diameter 1.30 - 2.10 inches for LC Shield Tape Shield/Wire Over Tape Shield. includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 1000.
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0. Cable Mounting Bracket - B1 - Stainless Steel - Size .80 inch - 1.25 inch.

R2T15J1-N0240-B1

Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 240 -Stranded or Compressed 1/0 Compact or Solid 2/0. Cable Mounting Bracket - B1 - Stainless Steel - Size .80 inch - 1.25 inch.
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 2 Hole Spade #2-1250kcmil, Stranded or Compressed #1 /Compact or Solid 1/0.

R2T15J1-N0230

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, Aluminum 2 Hole Spade #2-1250kcmil, Stranded or Compressed #1 /Compact or Solid 1/0.
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 220 -Stranded or Compressed #2 Compact or Solid #1.

R2T15J1-N0220

Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 220 -Stranded or Compressed #2 Compact or Solid #1.
Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 210 -Stranded or Compressed N/A Compact or Solid #2.

R2T15J1-N0210

Ranger2 Termination. Type - Outdoor, 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral, Insulation Range - .64 inch - 1.12 inch, Connector Type - Aluminum 2-Hole Spade #2-1250 kcmil, Conductor Code - 210 -Stranded or Compressed N/A Compact or Solid #2.
Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 1-Hole Spade connector for #2 to 500 kcmil. 4/0 Stranded or 250 kcmil Solid

R2T15J1-H0270

Ranger2 Termination for 15KV outdoor application, cable insulation diameter .64 - 1.12 inches for Concentric Neural and Jacketed Concentric Neutral Cable, includes Aluminum 1-Hole Spade connector for #2 to 500 kcmil. 4/0 Stranded or 250 kcmil Solid
Outdoor Ranger2 Cable Termination. 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral. Insulation Range - .64 inch - 1.12 inch. Aluminum 1-Hole Spade #2-500 kcmil, Conductor 1/0 Stranded/Compressed or 2/0 Compact/Solid

R2T15J1-H0240

Outdoor Ranger2 Cable Termination. 15kV, Cable Type - Concentric Neutral/Jacketed Concentric Neutral. Insulation Range - .64 inch - 1.12 inch. Aluminum 1-Hole Spade #2-500 kcmil, Conductor 1/0 Stranded/Compressed or 2/0 Compact/Solid
Ranger2 Termination for 15KV indoor application, cable insulation diameter 1.30 -2.10 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 500 /Compact or Solid 600

R2IT15M4N0330

Ranger2 Termination for 15KV indoor application, cable insulation diameter 1.30 -2.10 inches for Cable Type - Tape Shield, Wire Shield, and Unshielded Cable, includes Aluminum 2-Hole Spade connector for #2-1250 kcmil, Stranded or Compressed 500 /Compact or Solid 600

Frequently Asked Questions

What cable insulation diameters does the R2T termination cover?

The R2T termination covers cable insulation diameters from 0.64 inches (16 mm) to 2.10 inches (53 mm).

What is the maximum altitude for installing the R2T15 termination?

The R2T15 termination can be installed at a maximum altitude of 3300 feet (1005 m).

What is the minimum strike distance for the R2T15 termination?

The minimum strike distance for the R2T15 termination is 11.4 inches (381 mm).

What is the Lightning Impulse Withstand Voltage (BIL) for the R2T15?

The Lightning Impulse Withstand Voltage (BIL Dry 110 Withstand) is 110 kV Crest.

What is the IEEE classification for the outdoor R2T15 termination?

The IEEE classification for the outdoor R2T15 termination is Class 1A.

How is the R2T15 cable termination typically mounted?

The R2T15 cable termination can be free hanging or mounted with an optional bracket.

What power system frequencies are supported by the R2T15?

The R2T15 termination supports power system frequencies ranging from 48 to 62 Hz.

What is the ambient temperature range for the R2T15 termination?

The R2T15 termination operates within an ambient temperature range of -22 to +149 °F (-30 to +65 °C).

What is the maximum design voltage to ground for this termination?

The maximum design voltage to ground for the R2T15 termination is 9.5 kV.

What is the voltage rating of the R2T15 cable termination?

The R2T15 cable termination has a voltage rating of 15 kV.

How to Install the 15kV/28kV Ranger 2 Cable Termination

This guide provides detailed instructions for installing the 15kV and 28kV Ranger 2 Cable Termination on concentric and jacketed concentric neutral cables for indoor/outdoor applications. Ensure all safety precautions are followed.

Estimated time: 2h

Tools needed:

Wire strippers, Crimping tool, Measuring tape, Vinyl tape, Approved solvent, Aluminum oxide abrasive (optional, grit 120 or finer), Gloves

Supplies needed:

Silicone Rubber Termination kit, Silicone Lubricant, Grey Silicone Rubber Tape, Sealing Mastic, Connector/Lug (compatible with cable), Cable Support Bracket (optional), Binding wire (optional)

  1. Prepare Cable for Termination

    Check that the cable size fits within the kit's specified range. Train the cable into position and cut it to the required length, ensuring sufficient neutral wire length for the grounding connection. Prepare the cable according to the provided dimensions, accounting for terminal lug depth and additional exposed conductor distance for aluminum lugs.

  2. Apply Mastic and Secure Neutral Wires

    Wrap one band of sealing mastic around the cable jacket, 1/4 inch (6mm) from the jacket end, stretching it to 50%. Cut the mastic flush without overlapping. Bend the neutral wires back over the mastic, press them firmly into the seal, and secure them to the cable jacket 4-6 inches (100-150mm) from the cut edge using vinyl tape or binding wire. Apply a second mastic band over the neutral wires and the first mastic, stretching 50%, and cut it flush. Finally, wrap two half-lapped layers of vinyl tape around the mastic seal, carefully maintaining the 1/4 inch (6mm) dimension.

  3. Install the Lug or Connector

    If the chosen lug or connector will not fit through the termination core, clean the cable insulation and slide the termination body onto the cable before installing the lug. Do not remove the core at this stage. Position the connector or lug and crimp it according to its specific instructions, ensuring not to crimp the last 1/4 to 3/8 inch of the connector. After crimping, remove any excess oxide inhibitor and sharp crimp flashings.

  4. Clean Cable Insulation and Lug Barrel

    Wipe the cable insulation thoroughly with an approved solvent, taking care not to allow the solvent to touch the semi-con insulation shield. If an abrasive is necessary, use only aluminum oxide abrasive (grit 120 or finer) exclusively on the insulation. Do not use abrasive on the semi-con insulation shield, and ensure the cable insulation diameter is not reduced below the kit's allowed specifications.

  5. Apply Silicone Tape and Grease

    DANGER: Ensure all apparatus is de-energized before proceeding. Create a track-resistant moisture seal by wrapping a band of gray silicone rubber tape (from the kit) around the base of the terminal lug, between the termination insulator and the lug/connector. If the barrel diameter is smaller than the cable primary insulation, use the tape to build up the band to match the insulation diameter. Apply a liberal coating of silicone grease to the edge of the semi-con insulation shield to fill the step at the cut-off.

  6. Slide and Unwind Termination Body

    For terminations with a fold-down skirt, pull the loose end of the removable core through the top of the termination until it is flush with the bottom. Carefully slide the termination body onto the cable, aligning its forward edge with the mastic seal. Begin removing the core by unwinding it counter-clockwise from the loose end. Ensure the termination body, not the core, is firmly butted against the leading edge of the mastic seal, and avoid pushing or pulling the termination assembly during core removal.

  7. Complete Skirt and Moisture Seal

    Apply a thin film of silicone lubricant to the skirt and mastic seal area, but do not lubricate the skirt tabs. Carefully fold down the skirt over the mastic seal. Complete the lug area moisture seal using the remaining gray silicone rubber tape, overlapping the termination insulator by approximately 1 inch and extending the tape wrapping over a non-crimped region of the lug/connector barrel with a half-lap configuration.

  8. Ground Neutral Wires and Verify

    Twist the concentric neutral wires together and securely connect them to the system ground. Finally, confirm that the High-K step does not exceed 1.5 inches.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.